Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Nucl Med ; 51(10): 1539-44, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20847159

RESUMO

UNLABELLED: The aim of this study was to validate attenuation correction (AC) using low-dose standard CT for myocardial perfusion imaging (MPI) on a novel ultra fast γ-camera with cadmium-zinc-telluride (CZT) detector technology. METHODS: Sixty-six patients (body mass index ± SD, 27.2 ± 3.5 kg/m(2); range, 19.1-36.0 kg/m(2)) underwent a 1-d (99m)Tc-tetrofosmin adenosine stress-rest imaging protocol with 15-min acquisitions on a standard dual-head SPECT camera. All scans were repeated within minutes on the CZT camera, with 3-min acquisitions for stress (low dose) and 2-min acquisitions for rest (high dose) as recently established. We compared maximum myocardial uptake (20-segment model) from CZT versus standard SPECT MPI by intraclass correlation without and with CT AC. In addition, clinical agreement for each coronary territory for all scans from both devices was assessed, and Bland-Altmann (BA) limits of agreement for percentage uptake were calculated. RESULTS: The clinical agreement between CZT and standard SPECT cameras was 96% for noncorrected low- and high-dose images (r = 0.90 and BA = -18 to 15, and r = 0.91 and BA = -15 to 16, respectively), and agreement after AC was 96% for low- and 99% for high-dose images (r = 0.87 and BA = -16 to 14, and r = 0.88 and BA = -16 to 14, respectively). CONCLUSION: Our results support that AC of MPI on the novel CZT camera, compared with AC MPI on a conventional SPECT camera, is feasible because it provides a high correlation of segmental tracer uptake and an excellent clinical agreement.


Assuntos
Compostos de Cádmio , Imagem de Perfusão do Miocárdio/métodos , Intensificação de Imagem Radiográfica/métodos , Telúrio , Tomografia Computadorizada por Raios X/métodos , Transdutores , Zinco , Adulto , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Nucl Cardiol ; 17(5): 848-52, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20414755

RESUMO

BACKGROUND: The latest gamma-camera generation with cadmium-zinc-telluride (CZT) detectors allows myocardial perfusion imaging (MPI) with respiratory triggering at breath-hold. We assessed its impact on functional left ventricular (LV) parameters. METHODS: Twenty-eight consecutive patients underwent a one-day (99m)Tc-tetrofosmin pharmacologic stress/rest imaging protocol on a novel CZT camera. Electrocardiogram-gated high-dose (rest) MPI was performed without and with real-time respiratory triggering by intermittent scanning confined to breath-hold at deep inspiration. We studied the effect of respiratory triggering at deep inspiration levels on LV wall motion, wall thickening, LV volumes and ejection fraction (LVEF) compared to regular MPI without respiratory triggering. RESULTS: Compared to regular MPI without respiratory triggering, systolic and diastolic LV volumes and stroke volumes decreased significantly (P < 0.05) when respiratory triggering was applied. By contrast, there was no significant change in LVEF, with a high correlation (r = .939, P < 0.001) between the two measurements. Furthermore, respiratory triggering introduced a significant change (P < 0.05) in regional LV wall motion. CONCLUSIONS: Respiratory-triggered MPI with breath-hold at deep inspiration levels introduces significant changes to the measured LV volumes, stroke volumes and regional wall motion but does not significantly affect global LVEF when compared to regular MPI with normal breathing.


Assuntos
Imagem de Perfusão do Miocárdio/métodos , Respiração , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Função Ventricular Esquerda , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
J Nucl Med ; 51(1): 46-51, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20008999

RESUMO

UNLABELLED: We aimed at establishing the optimal scan time for nuclear myocardial perfusion imaging (MPI) on an ultrafast cardiac gamma-camera using a novel cadmium-zinc-telluride (CZT) solid-state detector technology. METHODS: Twenty patients (17 male; BMI range, 21.7-35.5 kg/m(2)) underwent 1-d (99m)Tc-tetrofosmin adenosine stress and rest MPI protocols, each with a 15-min acquisition on a standard dual-detector SPECT camera. All scans were immediately repeated on an ultrafast CZT camera over a 6-min acquisition time and reconstructed from list-mode raw data to obtain scan durations of 1 min, 2 min, etc., up to a maximum of 6 min. For each of the scan durations, the segmental tracer uptake value (percentage of maximum myocardial uptake) from the CZT camera was compared by intraclass correlation with standard SPECT camera data using a 20-segment model, and clinical agreement was assessed per coronary territory. Scan durations above which no further relevant improvement in uptake correlation was found were defined as minimal required scan times, for which Bland-Altman limits of agreement were calculated. RESULTS: Minimal required scan times were 3 min for low dose (r = 0.81; P < 0.001; Bland-Altman, -11.4% to 12.2%) and 2 min for high dose (r = 0.80; P < 0.001; Bland-Altman, -7.6% to 12.9%), yielding a clinical agreement of 95% and 97%, respectively. CONCLUSION: We have established the minimal scan time for a CZT solid-state detector system, which allows 1-d stress/rest MPI with a substantially reduced acquisition time resulting in excellent agreement with regard to uptake and clinical findings, compared with MPI from a standard dual-head SPECT gamma-camera.


Assuntos
Cádmio , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária/fisiologia , Câmaras gama , Coração/diagnóstico por imagem , Microcomputadores , Telúrio , Zinco , Adulto , Idoso , Idoso de 80 Anos ou mais , Relação Dose-Resposta a Droga , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Compostos Organofosforados , Compostos de Organotecnécio , Perfusão , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA