Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Clin Cardiol ; 44(8): 1177-1182, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34196416

RESUMO

BACKGROUND: Periprocedural pulmonary vein isolation (PVI) anticoagulation requires balancing between bleeding and thromboembolic risk. Intraprocedural anticoagulation is monitored by activated clotting time (ACT) with target value >300 s, and there are no guidelines specifying an initial unfractionated heparin (UFH) dose. METHODS: We aimed to assess differences in ACT values and UFH dosage during PVI in patients on different oral anticoagulants. We conducted an international, multi-center, registry-based study. Consecutive patients with atrial fibrillation (AF) undergoing PVI, on uninterrupted anticoagulation therapy, were analyzed. Before transseptal puncture, UFH bolus of 100 IU/kg was administered regardless of the anticoagulation drug. RESULTS: Total of 873 patients were included (median age 61 years, IQR 53-66; female 30%). There were 248, 248, 189, 188 patients on warfarin, dabigatran, rivaroxaban, and apixaban, respectively. Mean initial ACT was 257 ± 50 s, mean overall ACT 295 ± 45 s and total UFH dose 158 ± 60 IU/kg. Patients who were receiving warfarin and dabigatran compared to patients receiving rivaroxaban and apixaban had: (i) significantly higher initial ACT values (262 ± 57 and 270 ± 48 vs. 248 ± 42 and 241 ± 44 s, p < .001), (ii) significantly higher ACT throughout PVI (309 ± 46 and 306 ± 44 vs. 282 ± 37 and 272 ± 42 s, p < .001), and (iii) needed lower UFH dose during PVI (140 ± 39 and 157 ± 71 vs. 171 ± 52 and 172 ± 70 IU/kg). CONCLUSION: There are significant differences in ACT values and UFH dose during PVI in patients receiving different anticoagulants. Patients on warfarin and dabigatran had higher initial and overall ACT values and needed lower UFH dose to achieve adequate anticoagulation during PVI than patients on rivaroxaban and apixaban.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Dabigatrana/efeitos adversos , Feminino , Heparina/efeitos adversos , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Piridonas/efeitos adversos , Rivaroxabana/efeitos adversos
2.
Int J Cardiovasc Imaging ; 36(3): 415-422, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31712932

RESUMO

Fluoroscopy is the principal imaging method for catheter ablation (CA) of atrial fibrillation (AF). However, radiation exposure carries potential health risk to patients and operators alike. Our aim was to study safety and efficacy of zero-fluoroscopy CA of paroxysmal AF with a combined use of electroanatomic mapping system (EAM) and intracardiac echocardiography (ICE). In addition, impact of ICE/EAM automatic integration system and contact force (CF) sensing technology on procedural times were assessed. We included 144 consecutive patients (69% males, age 60 ± 10 years, BMI 29 ± 4,6) referred for CA of symptomatic paroxysmal AF. All procedures were performed only with EAM system and ICE. No fluoroscopy was used. The acute procedural success of complete pulmonary vein isolation was achieved in all patients (100%) and adverse events were detected in eight patients (5.6%). In 53 (37%) patients the use of ICE/EAM automatic integration system shortened procedural times compared to those performed without it (148 ± 35 vs. 187 ± 44 min, p < 0.05). Similarly, 89 (60%) procedures where CF sensing catheter was used were shorter compared to those performed without it (163 ± 41 vs. 188 ± 46 min, p < 0.05). Zero-fluoroscopy approach for treatment of paroxysmal AF seems feasible, safe, and acutely effective. Additional reduction of procedural times could be achieved with the use of ICE/EAM automatic integration system and CF sensing technology.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Ablação por Cateter , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Eslovênia , Fatores de Tempo , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 29(1): 64-70, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28884872

RESUMO

INTRODUCTION: Frequent ventricular premature complexes (VPCs) may cause symptoms and/or lead to deterioration of LV systolic function. Although frequent VPCs may be abolished by catheter ablation, it may be challenging in case of their origin from the LV papillary muscles (PMs). Our collaborative study aimed to analyze in detail the site of origin and the outcome of ablation. METHODS: Consecutive 34 patients (males: 68%; aged 62 ± 12 years; LV ejection fraction: 50 ± 9%) undergoing catheter ablation of VPCs originating from PMs were included. All procedures were guided by intracardiac echocardiography. RESULTS: The size and shape of PMs were highly variable. The length of anterolateral and posteromedial PM was 23 ± 4 mm and 28 ± 7 mm, respectively. In about one-third of patients, the PM was formed by two distinctly separate heads. The ectopic foci were located on anterolateral, posteromedial or both PM in 35%, 56% and 9% of cases, respectively. Their location was found within the distal, mid, or proximal (basal) third of PM in the 67%, 19%, and 14%, respectively. A total of 86% of PM foci were acutely abolished and long-term success was achieved in 65% of patients. Absence of VPCs of other morphologies and a high burden of ectopic activity before ablation were associated with favorable clinical outcome. CONCLUSION: VPCs originate predominantly from the distal portion of the PM. This knowledge may facilitate the mapping in patients with infrequent ectopic beats. Intracardiac echocardiography is of crucial importance for navigation of the ablation catheter and for assessment of its stability at PM target sites.


Assuntos
Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Músculos Papilares/fisiopatologia , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/fisiopatologia , Potenciais de Ação , Idoso , Ablação por Cateter , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Europa (Continente) , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/cirurgia , Fatores de Tempo , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
6.
Int J Cardiovasc Imaging ; 32(11): 1609-1616, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27491316

RESUMO

Electrophysiology study (EPS) and catheter ablation (CA) in children and adolescents carries a potentially harmful effect of radiation exposure when performed with the use of fluoroscopy. Our aim was to evaluate the feasibility, safety and effectiveness of fluoroless EPS and CA of various supra-ventricular tachycardias (SVTs) with the use of the 3D mapping system and intracardiac echocardiography (ICE). Forty-three consecutive children and adolescents (age 13 ± 3 years) underwent fluoroless EPS and CA for various supra-ventricular tachycardias. A three-dimensional (3D) mapping system NavX™ was used for guidance of diagnostic and ablation catheters in the heart. ICE was used as a fundamental imaging tool for transseptal punctures. Acute procedural success rate was 100 %. There were no procedure related complications and short-term follow up (10 ± 3 months) revealed 93 % arrhythmia free survival rate. Fluoroless CA of various SVTs in the paediatric population is feasible, safe and can be performed successfully with 3D mapping system and ICE.


Assuntos
Ablação por Cateter , Sistema de Condução Cardíaco/cirurgia , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Adolescente , Fatores Etários , Criança , Intervalo Livre de Doença , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Eslovênia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
7.
Europace ; 13(6): 869-75, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21186226

RESUMO

AIMS: To study anterograde atrioventricular (A-V) nodal electrophysiological properties through the right-atrial (Ri) and left-atrial inputs (Li) under the pharmacological autonomic blockade (AUB) in patients with slow-fast A-V nodal re-entrant tachycardia (AVNRT) and in controls. METHODS AND RESULTS: Twenty-nine patients with slow-fast AVNRT and 15 control subjects were included. Programmed stimulation with single extrastimulus was performed from the right atrial appendage to test the Ri, and from the posterolateral coronary sinus to test the Li. The AUB was induced with intravenous atropine (0.04 mg/kg) and metoprolol (0.15 mg/kg). The A-V nodal conduction times, refractoriness, discontinuous conduction (≥ 40 ms atrial-His interval 'jump'), and inducibility of AVNRT or reciprocating beats were compared. The A-V nodal conduction times were longer: (i) through the Ri than Li, (ii) in patients than controls, and (iii) in baseline than after AUB--at slow rates in both groups and at fast rates in patients through the right input only (P < 0.05-0.001). A significantly longer slow pathway effective refractory period was demonstrated through the Li than the Ri in patients in baseline (P < 0.05). The discontinuous conduction was demonstrated 94 times in 25 of 29 (83%) patients and 15 times in 6 of 15 (40%) controls (P < 0.01), and was most frequently encountered with the Ri testing. Likewise, inducibility was manifested most frequently with the Ri testing (P = 0.08), and decreased after AUB during this testing only (P = 0.05). CONCLUSION: The inherent magnitude of discordance of A-V nodal conduction velocity, refractoriness, and parasympathetic modulation between the Ri and Li to the A-V node may play a role in the aetiology of AVNRT.


Assuntos
Nó Atrioventricular/fisiopatologia , Fenômenos Eletrofisiológicos/fisiologia , Átrios do Coração/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Adulto , Antiarrítmicos/farmacologia , Atropina/farmacologia , Sistema Nervoso Autônomo/efeitos dos fármacos , Sistema Nervoso Autônomo/fisiopatologia , Fascículo Atrioventricular/fisiopatologia , Estudos de Casos e Controles , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Metoprolol/farmacologia , Pessoa de Meia-Idade , Taquicardia por Reentrada no Nó Atrioventricular/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA