Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
IEEE Trans Haptics ; 16(3): 379-390, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37436850

RESUMO

When using EMG biofeedback to control the grasping force of a myoelectric prosthesis, subjects need to activate their muscles and maintain the myoelectric signal within an appropriate interval. However, their performance decreases for higher forces, because the myoelectric signal is more variable for stronger contractions. Therefore, the present study proposes to implement EMG biofeedback using nonlinear mapping, in which EMG intervals of increasing size are mapped to equal-sized intervals of the prosthesis velocity. To validate this approach, 20 non-disabled subjects performed force-matching tasks using Michelangelo prosthesis with and without EMG biofeedback with linear and nonlinear mapping. Additionally, four transradial amputees performed a functional task in the same feedback and mapping conditions. The success rate in producing desired force was significantly higher with feedback (65.4±15.9%) compared to no feedback (46.2±14.9%) as well as when using nonlinear (62.4±16.8%) versus linear mapping (49.2±17.2%). Overall, in non-disabled subjects, the highest success rate was obtained when EMG biofeedback was combined with nonlinear mapping (72%), and the opposite for linear mapping with no feedback (39.6%). The same trend was registered also in four amputee subjects. Therefore, EMG biofeedback improved prosthesis force control, especially when combined with nonlinear mapping, which showed to be an effective approach to counteract increasing variability of myoelectric signal for stronger contractions.


Assuntos
Amputados , Membros Artificiais , Percepção do Tato , Humanos , Eletromiografia , Biorretroalimentação Psicológica , Desenho de Prótese
2.
J Neuroeng Rehabil ; 18(1): 87, 2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-34034762

RESUMO

BACKGROUND: Despite important advancements in control and mechatronics of myoelectric prostheses, the communication between the user and his/her bionic limb is still unidirectional, as these systems do not provide somatosensory feedback. Electrotactile stimulation is an attractive technology to close the control loop since it allows flexible modulation of multiple parameters and compact interface design via multi-pad electrodes. However, the stimulation interferes with the recording of myoelectric signals and this can be detrimental to control. METHODS: We present a novel compact solution for simultaneous recording and stimulation through dynamic blanking of stimulation artefacts. To test the system, a feedback coding scheme communicating wrist rotation and hand aperture was developed specifically to stress the myoelectric control while still providing meaningful information to the subjects. Ten subjects participated in an experiment, where the quality of closed-loop myoelectric control was assessed by controlling a cursor in a two degrees of freedom target-reaching task. The benchmark performance with visual feedback was compared to that achieved by combining visual feedback and electrotactile stimulation as well as by using electrotactile feedback only. RESULTS: There was no significant difference in performance between visual and combined feedback condition with regards to successfully reached targets, time to reach a target, path efficiency and the number of overshoots. Therefore, the quality of myoelectric control was preserved in spite of the stimulation. As expected, the tactile condition was significantly poorer in completion rate (100/4% and 78/25% for combined and tactile condition, respectively) and time to reach a target (9/2 s and 13/4 s for combined and tactile condition, respectively). However, the performance in the tactile condition was still good, with no significant difference in path efficiency (38/8%) and the number of overshoots (0.5/0.4 overshoots), indicating that the stimulation was meaningful for the subjects and useful for closed-loop control. CONCLUSIONS: Overall, the results demonstrated that the developed system can provide robust closed-loop control using electrotactile stimulation. The system supports different encoding schemes and allows placing the recording and stimulation electrodes next to each other. This is an important step towards an integrated solution where the developed unit will be embedded into a prosthetic socket.


Assuntos
Algoritmos , Artefatos , Membros Artificiais , Desenho de Prótese , Interface Usuário-Computador , Adulto , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Eletromiografia/métodos , Retroalimentação Sensorial/fisiologia , Feminino , Humanos , Masculino , Tato/fisiologia
3.
Med Biol Eng Comput ; 49(10): 1187-93, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21755318

RESUMO

Pathological tremor is manifested as an involuntary oscillation of one or more body parts. Tremor greatly decreases the quality of life and often prevents the patient from performing daily activities. We hypothesized that sensors-driven multichannel electrical stimulation could stabilize affected joints by activating the antagonistic muscles during involuntary activation of agonist muscles and vice versa (out-of-phase stimulation). Here, we present the new system (hardware and software) and the testing of its operation. The hardware consists of a multichannel stimulator and inertial sensors for feedback. The software implements adaptive sensors-driven control for the out-of-phase stimulation. The system was initially applied to healthy persons at the wrist and elbow joints to test the efficiency of the hardware and software solutions. Predefined rhythmic stimulation resulted in tremulous movement, which subjects could not prevent; yet, they were still able to functionally use their hand. The system was then applied to seven patients with Parkinson's disease and essential tremor for minimization of the wrist joint tremor. In six patients, the adaptive out-of-phase stimulation resulted in a significant decrease in the amplitude of tremor (67 ± 13%). In one patient, the stimulation did not result in the expected reduction of tremor.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Tremor/terapia , Adulto , Idoso , Terapia por Estimulação Elétrica/métodos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/complicações , Doença de Parkinson/terapia , Design de Software , Resultado do Tratamento , Tremor/etiologia , Extremidade Superior/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA