Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
JACC Clin Electrophysiol ; 9(3): 425-441, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36990601

RESUMO

Junctional tachycardia (JT) is typically considered to have an automatic mechanism originating from the distal atrioventricular node. When there is 1:1 retrograde conduction via the fast pathway, JT would resemble the typical form of atrioventricular nodal re-entrant tachycardia (AVNRT). Atrial pacing maneuvers have been proposed to exclude AVNRT and suggest a diagnosis of JT. However, after excluding AVNRT, one should consider the possibility of an infra-atrial narrow QRS re-entrant tachycardia, which can exhibit features that resemble AVNRT as well as JT. Pacing maneuvers and mapping techniques should be performed to assess for infra-atrial re-entrant tachycardia before concluding that JT is the mechanism of a narrow QRS tachycardia. Distinguishing JT from typical AVNRT or infra-atrial re-entrant tachycardia has notable implications regarding the approach to ablation of the tachycardia. Ultimately, a contemporary review of the evidence on JT raises some questions as to the mechanism and source of what has traditionally been considered JT.


Assuntos
Fibrilação Atrial , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Ectópica de Junção , Taquicardia Supraventricular , Humanos , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Ectópica de Junção/diagnóstico , Nó Atrioventricular , Fascículo Atrioventricular , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
2.
Circ Arrhythm Electrophysiol ; 11(4): e005785, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29654129

RESUMO

BACKGROUND: Atrial fibrillation recurrence after initial long-term success of catheter ablation has been described, yet not well studied. We assessed the electrophysiological findings and outcomes of repeat ablation procedures in this setting. METHODS AND RESULTS: Between 2000 and 2015, 10 378 patients underwent atrial fibrillation ablation and were enrolled in a prospectively maintained data registry. From this registry, we included all 137 consecutive patients who had initial long-term success, defined as freedom from recurrent arrhythmia for >36 months off antiarrhythmics, then underwent repeat ablation for recurrent atrial fibrillation. The median arrhythmia-free period that defined long-term success was 52 months (41-68 months). In redo ablations, reconnection along at least one of the pulmonary veins (PVs) was found in 111 (81%) patients. Reconnection along a left superior, left inferior, right superior, and right inferior PV was found in 64%, 62%, 50%, and 54% of patients, respectively, and were reisolated. Additional non-PV ablations were performed in 127 (92.7%) patients: posterior wall (46%), septal to right PVs (49%), superior vena cava (35%), roof lines (52%), and cavotricuspid isthmus (33%). After a median follow-up of 17 months (5-36.9 months), 103 patients (75%) were arrhythmia free (79 off antiarrhythmics, 24 on antiarrhythmics). CONCLUSIONS: PV reconnection is the most common electrophysiological finding in patients with atrial fibrillation recurrence after long-term success, but with lower rates than what had been reported for early recurrences. In our experience, repeat ablations in this setting involve complex ablation approaches to reisolate the PVs and modify the atrial substrate and are associated with good success rates.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Veias Pulmonares/cirurgia , Potenciais de Ação , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Frequência Cardíaca , Humanos , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Sistema de Registros , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
3.
Circ Arrhythm Electrophysiol ; 9(2): e003596, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26857909

RESUMO

BACKGROUND: Achieving long-term successful outcomes with ablation of persistent atrial fibrillation (AF) remains a clinical and procedural challenge. We aimed to assess 2 ablation strategies for persistent AF: pulmonary vein antral isolation (PVAI) in sinus rhythm after direct current cardioversion versus PVAI and ablation targeting complex-fractionated atrial electrograms while in AF. METHODS AND RESULTS: Between June 2009 and July 2013, patients with continuous persistent AF for ≥3 months were prospectively randomized to either direct current cardioversion before PVAI and posterior wall/septum ablation while in sinus rhythm (group 1), versus same ablation in group 1 in addition to complex-fractionated atrial electrogram ablation while in AF (group 2). The procedural profiles and clinical outcomes of the 2 strategies were compared. Ninety patients were randomized to group 1 (n=46) or group 2 (n=44). There were no differences in baseline characteristics between groups. Over 365 days of follow-up after the index procedure, 16 patients (35%) in group 1 and 13 patients (30%) in group 2 remained arrhythmia-free off antiarrhythmic medications. Over long-term follow-up (median, 867 days), arrhythmia-free survival off antiarrhythmic medications was more likely in group 1 than in group 2 in Kaplan-Meier analysis (Log Rank P=0.04). Group 1 ablation was associated with significantly shorter procedural duration and fluoroscopy time (231±72 versus 273±76 min; P=0.008 and 54 [Q1-Q3: 46-67] versus 66 (Q1-Q3: 53-83] min; P=0.018, respectively). CONCLUSIONS: In patients with persistent AF, PVAI in sinus rhythm after direct current cardioversion is associated with higher success and shorter procedural and fluoroscopy times compared with PVAI in AF with additional complex-fractionated atrial electrogram ablation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02429648.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca , Potenciais de Ação , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Eletrocardiografia Ambulatorial , Feminino , Fluoroscopia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Ohio , Duração da Cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos , Radiografia Intervencionista/métodos , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
J Interv Card Electrophysiol ; 37(1): 41-6, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23263895

RESUMO

OBJECTIVES: We sought to identify the characteristics, treatment, and outcomes of periprocedural cerebrovascular accident (PCVA) during electrophysiologic (EP) procedures. BACKGROUND: Periprocedural cerebrovascular accident is one of the most feared complications during EP procedures with very few data regarding its characteristics, management, and outcomes. METHODS: Between January 1998 and December 2008, we reviewed 30,032 invasive EP procedures for PCVA occurrence and characteristics. Management and outcomes were also determined. RESULTS: Thirty-eight CVAs were identified. Twenty (53 %) were intraprocedural and 18 (47 %) postprocedural. Thirty-two (84 %) were classified as strokes and six (16 %) as transient ischemic attacks. All CVAs except one (37, 97 %) were ischemic and the vast majority occurred during ablation procedures (36, 95 %). Among the 31 patients with ischemic stroke, 11 (35 %) were treated with reperfusion (eight catheter-based therapy and three intravenous t-PA) of whom five (46 %) had complete recovery, three (27 %) had partial recovery, and three (27 %) had no recovery. No hemorrhagic transformations occurred. CONCLUSION: Periprocedural cerebrovascular accident during EP procedures is rare and is almost always ischemic. It occurs more frequently during ablation procedures. Reperfusion therapy is feasible and safe.


Assuntos
Cateterismo Cardíaco/mortalidade , Técnicas Eletrofisiológicas Cardíacas/mortalidade , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/terapia , Idoso , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Ohio/epidemiologia , Estudos Retrospectivos , Medição de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
5.
Heart Rhythm ; 9(6): 859-64, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22293139

RESUMO

BACKGROUND: Ventricular tachyarrhythmias (VT) are common among ventricular assist device (VAD) recipients, yet electrophysiologic (EP) characteristics and catheter ablation outcomes remain uncharacterized. OBJECTIVE: To evaluate the EP characteristics and catheter ablation outcomes for VTs among heart failure patients on VAD support. METHODS: The Cleveland Clinic registry of consecutive patients undergoing VAD placement in 1991-2010 with medically refractory, symptomatic VT referred for EP study and catheter ablation. RESULTS: Among 611 recipients of VAD (mean age 53.3 ± 12.4 years, 80% men), 21 patients (3.4%) were referred for 32 EP procedures, including 11 patients (52%) presenting with implantable cardioverter-defibrillator therapy (13 shocks, 26 antitachycardia pacing). Data from 44 inducible tachycardias (mean cycle length 339 ± 59 ms) demonstrated monomorphic VT (n = 40, 91%; superior axis 52%, right bundle branch block morphology 41%) and polymorphic ventricular tachycardia (PMVT)/ventricular fibrillation (n = 4, 8%). Electroanatomic mapping of 28 tachycardias in 20 patients demonstrated reentrant VT related to intrinsic scar (n = 21 of 28, 75%) more commonly than the apical inflow cannulation site (n = 4 of 28, 14%), focal/microreentry VT (n = 2 of 28, 7%), or bundle branch reentry (n = 1 of 28, 3.5%). Catheter ablation succeeded in 18 of 21 patients (86%). VT recurred in 7 of 21 patients (33%) at a mean of 133 ± 98 days, and 6 patients (29%) required repeat procedures, with subsequent recurrence in 4 of 21 patients (19%). CONCLUSIONS: Catheter ablation of VT is effective among recipients of VAD. Intrinsic myocardial scar, rather than the apical device cannulation site, appears to be the dominant substrate.


Assuntos
Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/cirurgia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar/efeitos adversos , Taquicardia Ventricular/fisiopatologia , Fenômenos Eletrofisiológicos , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
6.
J Am Coll Cardiol ; 50(9): 868-74, 2007 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-17719473

RESUMO

OBJECTIVES: We aimed at assessing the feasibility and efficacy of remote magnetic navigation (MN) and ablation in patients with atrial fibrillation (AF). BACKGROUND: This novel MN system could facilitate standardization of the procedures, reducing the importance of the operator skill. METHODS: After becoming familiar with the system in 48 previous patients, 45 consecutive patients with AF were considered for ablation using the Niobe II remote magnetic system (Stereotaxis, St. Louis, Missouri) in a stepwise approach: circumferential pulmonary vein ablation (CPVA), pulmonary vein antrum isolation (PVAI), and, if failed, PVAI using the conventional approach. Remote navigation was done using the coordinate or the wand approach. Ablation end point was electrical disconnection of the pulmonary veins (PVs). RESULTS: Using the coordinate approach, the target location was reached in only 60% of the sites, whereas by using the wand approach 100% of the sites could be reached. After step 2 ablation, only 1 PV in 4 patients (8%) could be electrically isolated. Charring on the ablation catheter tip was seen in 15 (33%) of the cases. In 23 patients, all PVs were isolated with the conventional thermocool catheter, and in 22 patients only the right PVs were isolated with the conventional catheter. After a mean follow-up period of 11 +/- 2 months, recurrence was seen in 5 patients (22%) with complete PVAI and in 20 patients (90%) with incomplete PVAI. CONCLUSIONS: Remote navigation using a magnetic system is a feasible technique. With the present catheter technology, effective lesions cannot be achieved in most cases. This appears to impact the cure rate of AF patients.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Robótica , Idoso , Cateterismo , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Magnetismo , Masculino , Pessoa de Meia-Idade
7.
J Am Coll Cardiol ; 49(15): 1634-1641, 2007 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-17433955

RESUMO

OBJECTIVES: We sought to test how catheter ablation using an open irrigation catheter (OIC) compares with standard catheters for pulmonary vein antrum isolation. BACKGROUND: Open irrigation catheters have the advantage of delivering greater power without increasing the temperature of the catheter tip, which enables deeper and wider lesions without the formation of coagulum on catheters. METHODS: Catheter ablation was performed using an 8-mm catheter (8MC) or an OIC. Patients were randomized to 3 groups: 8MC; OIC-1, OIC with a higher peak power (50 W); and OIC-2, OIC with lower peak power (35 W). RESULTS: A total of 180 patients were randomized to the 3 treatment strategies. Isolation of pulmonary vein antra was achieved in all patients. The freedom from atrial fibrillation was significantly greater in the 8MC and OIC-1 groups compared with the OIC-2 group (78%, 82%, and 68%, respectively, p = 0.043). Fluoroscopy time was lower in OIC-1 compared with OIC-2 and 8MC (28 +/- 1 min, 53 +/- 2 min, and 46 +/- 2 min, respectively, p = 0.001). The mean left atrium instrumentation time was lower in the OIC-1 compared with the OIC-2 and 8MC groups (59 +/- 3 min, 90 +/- 5 min, and 88 +/- 4 min, respectively, p = 0.001). However, there was a greater incidence of "pops" in the OIC-1 (100%, 0%, 0%, p < 0.001) along with higher incidences of pericardial effusion (20%, 0%, 0%, p < 0.001) and gastrointestinal complaints (17% in OIC-1, 3% in 8MC, and 5% in OIC-2, p = 0.031). CONCLUSIONS: Although there was a decrease in fluoroscopy and left atrium instrumentation time with the use of OIC at higher power, this setting was associated with increased cardiovascular and gastrointestinal complications.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Veias Pulmonares/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Ablação por Cateter/instrumentação , Ecocardiografia Doppler , Eletrocardiografia , Feminino , Seguimentos , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Cuidados Pós-Operatórios/métodos , Probabilidade , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Irrigação Terapêutica/instrumentação , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA