1.
Med Phys ; 51(3): 1653-1673, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38323878

RESUMO

BACKGROUND: Dual-energy (DE) detection of bone marrow edema (BME) would be a valuable new diagnostic capability for the emerging orthopedic cone-beam computed tomography (CBCT) systems. However, this imaging task is inherently challenging because of the narrow energy separation between water (edematous fluid) and fat (health yellow marrow), requiring precise artifact correction and dedicated material decomposition approaches. PURPOSE: We investigate the feasibility of BME assessment using kV-switching DE CBCT with a comprehensive CBCT artifact correction framework and a two-stage projection- and image-domain three-material decomposition algorithm. METHODS: DE CBCT projections of quantitative BME phantoms (water containers 100-165 mm in size with inserts presenting various degrees of edema) and an animal cadaver model of BME were acquired on a CBCT test bench emulating the standard wrist imaging configuration of a Multitom Rax twin robotic x-ray system. The slow kV-switching scan protocol involved a 60 kV low energy (LE) beam and a 120 kV high energy (HE) beam switched every 0.5° over a 200° angular span. The DE CBCT data preprocessing and artifact correction framework consisted of (i) projection interpolation onto matched LE and HE projections views, (ii) lag and glare deconvolutions, and (iii) efficient Monte Carlo (MC)-based scatter correction. Virtual non-calcium (VNCa) images for BME detection were then generated by projection-domain decomposition into an Aluminium (Al) and polyethylene basis set (to remove beam hardening) followed by three-material image-domain decomposition into water, Ca, and fat. Feasibility of BME detection was quantified in terms of VNCa image contrast and receiver operating characteristic (ROC) curves. Robustness to object size, position in the field of view (FOV) and beam collimation (varied 20-160 mm) was investigated. RESULTS: The MC-based scatter correction delivered > 69% reduction of cupping artifacts for moderate to wide collimations (> 80 mm beam width), which was essential to achieve accurate DE material decomposition. In a forearm-sized object, a 20% increase in water concentration (edema) of a trabecular bone-mimicking mixture presented as ∼15 HU VNCa contrast using 80-160 mm beam collimations. The variability with respect to object position in the FOV was modest (< 15% coefficient of variation). The areas under the ROC curve were > 0.9. A femur-sized object presented a somewhat more challenging task, resulting in increased sensitivity to object positioning at 160 mm collimation. In animal cadaver specimens, areas of VNCa enhancement consistent with BME were observed in DE CBCT images in regions of MRI-confirmed edema. CONCLUSION: Our results indicate that the proposed artifact correction and material decomposition pipeline can overcome the challenges of scatter and limited spectral separation to achieve relatively accurate and sensitive BME detection in DE CBCT. This study provides an important baseline for clinical translation of musculoskeletal DE CBCT to quantitative, point-of-care bone health assessment.


Assuntos
Medula Óssea , Tomografia Computadorizada de Feixe Cônico , Humanos , Medula Óssea/diagnóstico por imagem , Estudos de Viabilidade , Tomografia Computadorizada de Feixe Cônico/métodos , Algoritmos , Imagens de Fantasmas , Edema , Cadáver , Água , Espalhamento de Radiação , Processamento de Imagem Assistida por Computador/métodos
2.
Phys Med Biol ; 68(8)2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36893466

RESUMO

Objective. In mammography, breast compression forms an essential part of the examination and is achieved by lowering a compression paddle on the breast. Compression force is mainly used as parameter to estimate the degree of compression. As the force does not consider variations of breast size or tissue composition, over- and undercompression are a frequent result. This causes a highly varying perception of discomfort or even pain in the case of overcompression during the procedure. To develop a holistic, patient specific workflow, as a first step, breast compression needs to be thoroughly understood. The aim is to develop a biomechanical finite element breast model that accurately replicates breast compression in mammography and tomosynthesis and allows in-depth investigation. The current work focuses thereby, as a first step, to replicate especially the correct breast thickness under compression.Approach. A dedicated method for acquiring ground truth data of uncompressed and compressed breasts within magnetic resonance (MR) imaging is introduced and transferred to the compression within x-ray mammography. Additionally, we created a simulation framework where individual breast models were generated based on MR images.Main results. By fitting the finite element model to the results of the ground truth images, a universal set of material parameters for fat and fibroglandular tissue could be determined. Overall, the breast models showed high agreement in compression thickness with a deviation of less than ten percent from the ground truth.Significance. The introduced breast models show a huge potential for a better understanding of the breast compression process.


Assuntos
Neoplasias da Mama , Compressão de Dados , Humanos , Feminino , Mama/diagnóstico por imagem , Mama/patologia , Mamografia/métodos , Pressão , Simulação por Computador , Neoplasias da Mama/patologia
3.
Phys Med Biol ; 61(4): 1572-95, 2016 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-26835839

RESUMO

This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x-ray photon flux.


Assuntos
Fótons , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Tomografia Computadorizada por Raios X/instrumentação , Raios X