Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 20(21)2020 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-33105890

RESUMO

(1) Background: Acute acoustic (sound) stimulus prompts a state of defensive motivation in which unconscious muscle responses are markedly enhanced in humans. The orbicularis oculi (OO) of the eye is an easily accessed muscle common for acoustic startle reaction/response/reflex (ASR) investigations and is the muscle of interest in this study. Although the ASR can provide insights about numerous clinical conditions, existing methodologies (Electromyogram, EMG) limit the usability of the method in real clinical conditions. (2) Objective: With EMG-free muscle recording in mind, our primary aim was to identify and investigate potential correlations in the responses of individual and cooperative OO muscles to various acoustic stimuli using a mobile and wire-free system. Our secondary aim was to investigate potential altered responses to high and also relatively low intensity acoustics at different frequencies in both sitting and standing positions through the use of biaural sound induction and video diagnostic techniques and software. (3) Methods: This study used a mobile-phone acoustic startle response monitoring system application to collect blink amplitude and velocity data on healthy males, aged 18-28 community cohorts during (n = 30) in both sitting and standing postures. The iPhone X application delivers specific sound parameters and detects blinking responses to acoustic stimulus (in millisecond resolution) to study the responses of the blinking reflex to acoustic sounds in standing and sitting positions by using multiple acoustic test sets of different frequencies and amplitudes introduced as acute sound stimuli (<0.5 s). The single acoustic battery of 15 pure-square wave sounds consisted of frequencies and amplitudes between 500, 1000, 2000, 3000, and 4000 Hz scales using 65, 90, and 105 dB (e.g., 3000 Hz_90 dB). (4) Results: Results show that there was a synchronization of amplitude and velocity between both eyes to all acoustic startles. Significant differences (p = 0.01) in blinking reaction time between sitting vs. standing at the high intensity (105 dB) 500 Hz acoustic test set was discovered. Interestingly, a highly significant difference (p < 0.001) in response times between test sets 500 Hz_105 dB and 4000 Hz_105 dB was identified. (5) Conclusions: To our knowledge, this is the first mobile phone-based acoustic battery used to detect and report significant ASR responses to specific frequencies and amplitudes of sound stimulus with corresponding sitting and standing conditions. The results from this experiment indicate the potential significance of using the specific frequency, amplitude, and postural conditions (as never before identified) which can open new horizons for ASR to be used for diagnosis and monitoring in numerous clinical and remote or isolated conditions.


Assuntos
Telefone Celular , Postura , Reflexo de Sobressalto , Estimulação Acústica , Adolescente , Adulto , Piscadela , Eletromiografia , Humanos , Masculino , Adulto Jovem
2.
Neurogastroenterol Motil ; 32(7): e13852, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32281229

RESUMO

BACKGROUNDS: Gastric motility is regulated by an electrophysiological activity called slow-wave and neuronal innervations by the vagus nerve. Transcutaneous auricular vagal nerve stimulation (taVNS) has been demonstrated to have therapeutic potential for a wide range of medical conditions, including the management of gastric dysfunctions. The main objective of this study was to gain a better understanding of how non-invasive neuromodulation influences gastric slow wave under in vivo conditions. METHODS: TaVNS protocols were applied in conjunction with 192-channel gastric bioelectrical mapping in porcine subjects under general anesthesia. The spatiotemporal profiles of gastric slow wave were assessed under two different taVNS protocols at 10 and 80 Hz. KEY RESULTS: The taVNS protocols effectively altered the interval and amplitude of gastric slow waves, but not the velocity or the percentage of spatial dysrhythmias. In the subjects that responded to the protocols, the 10 Hz protocol was shown to normalize slow-wave propagation pattern in 90% of the subjects, whereas the 80 Hz protocol was shown to inhibit slow waves in 60% of the subjects. CONCLUSIONS AND INFERENCES: Chronic responses of gastric motility and slow waves in response to taVNS should be investigated using non-invasive means in conscious subjects in future.


Assuntos
Motilidade Gastrointestinal , Estômago/fisiologia , Estimulação Elétrica Nervosa Transcutânea/métodos , Estimulação do Nervo Vago/métodos , Animais , Orelha Externa/inervação , Orelha Externa/fisiologia , Feminino , Estômago/inervação , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA