Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Orthopedics ; 41(3): 158-163, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29738600

RESUMO

The purpose of this study was to assess (1) the prevalence of the fracture of ceramic heads implanted on used trunnions of well-fixed stems without using a titanium adapter sleeve; (2) the prevalence of trunnionosis secondary to fretting and/or corrosion at the trunnion of the well-fixed stem; and (3) clinical and radiographic results and the survival rate of the revised acetabular components. Eighty-eight patients (100 hips) underwent isolated revision of the acetabular components for polyethylene wear and osteolysis of the acetabulum. The study group consisted of 70 men and 18 women with a mean age of 52.8 years (range, 31-54 years) when the primary total hip arthroplasty was performed. Evidence of fretting and corrosion of the trunnion of all prostheses was examined macroscopically using a magnifying lens. Degree of fretting and corrosion of the trunnion was assessed using a 4-point scoring technique. A new 36-mm alumina delta ceramic head was implanted on the trunnion of a well-fixed stem without using a titanium adapter sleeve in all hips. The mean follow-up after revision of the acetabular component was 12.8 years (range, 10-14 years). Among the 100 new ceramic heads implanted on a well-fixed stem, no fracture of the ceramic head occurred at a mean follow-up of 12.8 years. The median fretting and corrosion scores for the trunnions were 1.5±1.1 and 1.3±0.9 points, respectively. The mean Harris hip score at the final follow-up was 89±15 points (range, 63-100 points). Survivorship of the revised acetabular components at 14 years was 95% (95% confidence interval, 87.6%-98.6%). [Orthopedics. 2018; 41(3):158-163.].


Assuntos
Óxido de Alumínio/efeitos adversos , Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Falha de Prótese/efeitos adversos , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Corrosão , Feminino , Seguimentos , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Polietileno/efeitos adversos , Desenho de Prótese , Reoperação , Fatores de Tempo , Resultado do Tratamento
2.
J Arthroplasty ; 31(12): 2800-2804, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27378639

RESUMO

BACKGROUND: The purpose of this retrospective study was to determine the clinical and radiographic results, prevalence of polyethylene wear and osteolysis, and fracture of alumina delta ceramic femoral head or highly crosslinked, remelted polyethylene (HXLPE) liner associated with the use of alumina delta ceramic femoral head-on-HXLPE bearing in cementless total hip arthroplasty in patients younger than 50 years. METHODS: We reviewed the cases of 119 patients (130 hips) who underwent a cementless total hip arthroplasty using alumina delta ceramic-on-HXLPE bearing when they were 50 years or younger at the time of surgery. The most common diagnoses were osteonecrosis (51%) and osteoarthritis secondary to developmental dysplastic hip (39%). Osteolysis and polyethylene wear rates were evaluated with use of radiography and computed tomography. In addition, prevalence of fracture of alumina delta ceramic head and polyethylene line was documented. The mean follow-up was 8.3 years (range, 7-9 years). RESULTS: The mean Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index score, University of California, Los Angeles activity score were 94 points, 14 points, and 8.1 points, respectively, at the final follow-up. No patient had thigh pain. All acetabular components and all but one femoral components were well fixed. The mean annual penetration rate of femoral head was 0.022 ± 0.003 mm/year. No hip had osteolysis or ceramic head or HXLPE liner fracture. CONCLUSION: Our average 8.3-year results with the use of alumina delta ceramic-on-HXLPE bearing in the patients younger than 50 years suggest that cementless acetabular and femoral components provide a high survival rate without evidence of osteolysis or ceramic head or AXLPE liner fracture.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/estatística & dados numéricos , Desenho de Prótese , Acetábulo/cirurgia , Adulto , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/estatística & dados numéricos , Cerâmica , Feminino , Cabeça do Fêmur/cirurgia , Necrose da Cabeça do Fêmur/cirurgia , Seguimentos , Luxação Congênita de Quadril/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/etiologia , Osteoartrite do Quadril/cirurgia , Osteólise/diagnóstico por imagem , Osteólise/epidemiologia , Osteólise/etiologia , Polietileno , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , República da Coreia/epidemiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
3.
J Arthroplasty ; 31(11): 2520-2524, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27172862

RESUMO

BACKGROUND: The results of third-generation of alumina-on-alumina ceramic bearing in a large number of patient cohorts are limited. The purpose of this study was to determine clinical and radiologic outcome, prevalence of osteolysis detected with radiographs and computerized tomographic scan, and survivorship of a cementless total hip arthroplasty using a third-generation of alumina-on-alumina ceramic bearing in a large number of active patients aged younger than 65 years. METHODS: We reviewed the cases of 871 patients (1131 hips) who underwent a cementless total hip arthroplasty when they were aged 65 years or younger at the time of surgery. The most common diagnoses were osteonecrosis (53%) and osteoarthritis (20%). Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index, and University of California, Los Angeles activity scores were recorded. Radiographic and computerized tomographic evaluations were used to evaluate implant fixation and osteolysis. The mean follow-up interval was 18.8 years (range, 15-20 years). RESULTS: At the time of final follow-up, the mean Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index score, and University of California, Los Angeles activity score were 90 points, 15 points, and 8 points, respectively. All the femoral stem and acetabular components were well-fixed at the time of final follow-up. No hip had aseptic loosening or osteolysis or fracture of ceramic material at the time of the final follow-up. CONCLUSION: The current results with the use of the third-generation of alumina-on-alumina ceramic bearings in young patients suggest that cementless acetabular and femoral components provide outstanding long-term fixation and provide a high rate of survivorship without evidence of osteolysis.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril/instrumentação , Cerâmica , Prótese de Quadril , Osteólise/epidemiologia , Adulto , Artroplastia de Quadril/efeitos adversos , Feminino , Fêmur/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/etiologia , Prevalência , Desenho de Prótese , Radiografia , República da Coreia/epidemiologia , Resultado do Tratamento , Adulto Jovem
4.
J Arthroplasty ; 31(10): 2209-14, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27067468

RESUMO

BACKGROUND: There are limited studies to evaluate long-term clinical and radiographic outcomes of alumina delta ceramic-on-ceramic bearings in cementless total hip arthroplasty (THA). The purpose of this study was to evaluate the clinical and radiographic results, prevalence of osteolysis, squeaking, and fracture of ceramic material associated with the use of the alumina delta ceramic-on-alumina delta ceramic bearing in cementless THA in patients aged <50 years. METHODS: We reviewed the cases of 277 patients (334 hips) who underwent a cementless THA using alumina delta ceramic-on-alumina delta ceramic when they were 50 years or younger at the time of surgery. Demographic data; Harris Hip Score; Western Ontario McMaster Universities Osteoarthritis Index; and University of California, Los Angeles activity score were recorded. Radiographic and computerized tomographic evaluations were used to evaluate implant fixation and osteolysis. Squeaking sound and ceramic fracture were documented. The mean follow-up was 13.1 years (range, 10-14). RESULTS: The mean postoperative Harris Hip Score, Western Ontario and McMaster Universities Osteoarthritis Index score, University of California, Los Angeles activity score were 93 points, 15 points, and 8.6 points, respectively. Two patients had thigh pain (grade 7 points). All acetabular components and all but 2 femoral components were well fixed. Thirty-three hips (10%) exhibited clicking sound, and 2 hips (0.6%) exhibited squeaking sound. No hip had osteolysis or ceramic head or liner fracture. CONCLUSION: Our minimum 10-year follow-up results with the use of alumina delta ceramic-on-alumina delta ceramic bearings in patients aged <50 years suggest that cementless THA provides a high rate of survivorship without evidence of osteolysis or fracture of ceramic material.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril/instrumentação , Prótese de Quadril , Osteólise/epidemiologia , Acetábulo/cirurgia , Adulto , Doenças Ósseas/cirurgia , Cerâmica , Feminino , Necrose da Cabeça do Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Osteólise/etiologia , Desenho de Prótese , República da Coreia/epidemiologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
5.
J Arthroplasty ; 26(2): 218-23, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20452176

RESUMO

We asked whether total hip arthroplasties (THAs) using alumina-on-highly cross-linked polyethylene bearing would improve functional activity and reduce aseptic loosening, polyethylene wear, and osteolysis. Consecutive primary THAs were performed in 71 patients (73 hips) who were younger than 50 years (mean age, 45.5 years) with femoral head osteonecrosis. There were 48 men (50 hips) and 23 women (23 hips). Osteolysis was evaluated using radiographs and computed tomographic scanning. The average follow-up was 8.5 years (range, 7-9 years). The mean preoperative Harris hip score was 50.6 points, which improved to 96 points at the final follow-up. Preoperative functional activity was improved significantly at the latest follow-up. The mean polyethylene linear penetration was 0.05 ± 0.02 mm/y and no hip had aseptic loosening or osteolysis.


Assuntos
Artroplastia de Quadril/métodos , Necrose da Cabeça do Fêmur/cirurgia , Prótese de Quadril , Adulto , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Feminino , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/epidemiologia , Osteólise/etiologia , Polietileno , Desenho de Prótese , Adulto Jovem
6.
Int Orthop ; 34(8): 1123-7, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19784647

RESUMO

Despite improvements in the quality of alumina ceramics, osteolysis has been reported anecdotally after total hip arthroplasty (THA) with use of a contemporary alumina-on-alumina ceramic bearing. The purpose of this study was to evaluate the clinical and radiographic outcomes of THA using alumina-on-alumina ceramic bearing and to determine osteolysis using radiographs and computed tomographic (CT) scans in young patients. Consecutive primary cementless THA using alumina-on-alumina ceramic bearing were performed in 64 patients (93 hips) who were younger than 45 years of age with femoral-head osteonecrosis. There were 55 men (84 hips) and nine women (nine hips). Average age was 38.2 (range 24-45) years. Average follow-up was 11.1 (range 10-13) years. Preoperative Harris Hip Score was 52.9 (range 22-58) points, which improved to 96 (range 85-100) points at the final follow-up examination. Two of 93 hips (2%) had clicking or squeaking sound. No hip had revision or aseptic loosening. Radiographs and CT scans demonstrated that no acetabular or femoral osteolysis was detected in any hip at the latest follow-up. Contemporary cementless acetabular and femoral components with alumina-on-alumina ceramic bearing couples function well with no osteolysis at a ten year minimum and average of 11.1-year follow-up in this series of young patients with femoral-head osteonecrosis.


Assuntos
Artroplastia de Quadril/métodos , Cerâmica , Necrose da Cabeça do Fêmur/cirurgia , Articulação do Quadril/cirurgia , Prótese de Quadril , Adulto , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Cimentação , Materiais Revestidos Biocompatíveis , Feminino , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/fisiopatologia , Indicadores Básicos de Saúde , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico , Osteólise/etiologia , Complicações Pós-Operatórias , Desenho de Prótese , Falha de Prótese , Radiografia , Amplitude de Movimento Articular , Resultado do Tratamento , Adulto Jovem
7.
J Arthroplasty ; 24(6): 885-91, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18617363

RESUMO

This study compared the clinical and radiographic results and the prevalence of osteolysis between alumina-on-alumina and alumina-on-highly cross-linked polyethylene bearings after cementless total hip arthroplasties in the 100 patients younger than 50 years of age. There were 66 men and 34 women; the mean age at the time of surgery was 45.3 years (range, 25 to 49 years). The mean duration of follow-up was 5.6 years (range, five to seven years). The pre-and postoperative Harris hip scores were similar (39 and 41 points, respectively and 93 points and 94 points, respectively). No acetabular or femoral component had aseptic loosening in either group. The mean annual penetration of the highly cross-linked polyethylene was 0.06 +/- 0.03 mm. No hip in either group had acetabular or femoral osteolysis.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril/instrumentação , Prótese de Quadril , Osteonecrose/cirurgia , Polietileno , Adulto , Óxido de Alumínio/efeitos adversos , Artroplastia de Quadril/métodos , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiologia , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Osteólise/epidemiologia , Polietileno/efeitos adversos , Radiografia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA