Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Medicinas Complementares
Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Neurosurgery ; 77(4): 544-52; discussion 552, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26308642

RESUMO

BACKGROUND: Endovascular therapy is favored for ruptured intracranial aneurysms in the elderly. However, poor accessibility to the aneurysm through the parent artery and use of local anesthesia in this age group may predispose to intraprocedural complications. OBJECTIVE: To evaluate whether age-related poor access to the ruptured target aneurysm and use of local anesthesia are associated with increased incidence of procedure-related rupture during endovascular embolization. METHODS: A total of 117 patients with 117 ruptured aneurysms underwent endovascular embolization at a single institution. Correlation of increasing age with poor accessibility of the guiding catheter was analyzed. In addition, the distance from the aneurysm to the guiding catheter was investigated to identify an association with incidence of procedure-related rupture. Correlation of local anesthesia with procedure-related rupture was also evaluated in the multivariable analysis. RESULTS: Increasing age was significantly associated with poor accessibility of the guiding catheter (P = .001, Mann-Whitney U test). Procedure-related rupture occurred in 9 of 117 aneurysms (7.7%). Longer distance between distal aneurysms and low-positioned guiding catheters carried a higher risk of procedure-related rupture than a shorter distance between proximal aneurysms and high-positioned guiding catheters (odds ratio, 19.3; 95% confidence interval, 1.84-201; P = .01, multivariable analysis). Use of local anesthesia was also a significant risk factor of procedure-related rupture by multivariable analysis. CONCLUSION: Increasing age was correlated with poor accessibility of the guiding catheter in endovascular embolization of ruptured intracranial aneurysms. Distally located aneurysms treated through a low-positioned guiding catheter and use of local anesthesia increased the risk of procedure-related rupture.


Assuntos
Anestesia Local/efeitos adversos , Aneurisma Roto/diagnóstico por imagem , Catéteres/efeitos adversos , Embolização Terapêutica/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Aneurisma Intracraniano/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/etiologia , Feminino , Humanos , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Radiografia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA