1.
Ear Hear ; 45(1): 115-129, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37475147

RESUMO

OBJECTIVES: The contralateral medial olivocochlear reflex (MOCR) strength may indicate various auditory conditions in humans, but a clinically viable assay and equipment are needed for quick, accurate, and reliable measurements. The first experiment compared an earlier version of the assay, which used a nonlinear-mode chirp stimulus, with a new assay using a linear-mode click stimulus, designed to give reliable MOCR measurements in most normal-hearing ears. The second experiment extended the improved assay on a purpose-built binaural hardware platform that used forward-pressure level (FPL) calibration for both the stimulus and the contralateral MOCR elicitor. DESIGN: Transient-evoked otoacoustic emission (TEOAE) tests were measured with and without a 60-dB SPL MOCR-evoking contralateral broadband noise. The normalized MOCR strength (MOCR%) was derived from the TEOAE responses for each trial pair using the complex pressure difference weighted by the TEOAE magnitude. Experiment 1 compared MOCR% within-subject and across-day using two TEOAE stimuli: nonlinear-mode chirps (50 dB SPL, bandpass 1-5 kHz, 14 ms window delayed by 2 ms) and linear-mode clicks (50 dB SPL, bandpass 0.5-2.5 kHz, 13 ms window delayed by 5 ms). TEOAE responses were analyzed in the 0.5 to 2.5 kHz band. Thirty adult participants with normal hearing (30 ears) completed the study. The TEOAE stimulus was calibrated in situ using spectral flattening, and the contralateral noise was calibrated in a coupler. Twelve TEOAE trial pairs were collected for each participant and condition. Experiment 2 used a purpose-built binaural system. The TEOAE stimuli were linear-mode clicks (50 dB SPL, bandpass 1-3 kHz, 13 ms window delayed by 5 ms), analyzed in the 1 to 3 kHz band over ~12 trial pairs. After a probe refit, an additional trial pair was collected for the two early-stopping signal-to-noise ratio criteria (15 and 20 dB). They were evaluated for single-trial reliability and test time. Nineteen adult participants with normal hearing (38 ears) completed the study. The TEOAE clicks and contralateral elicitor noise were calibrated in situ using FPL and delivered with automated timing. RESULTS: MOCR% for linear-mode clicks was distinguishable from measurement variability in 98% to 100% of participants' ears (both experiments), compared with only 73% for the nonlinear-mode chirp (experiment 1). MOCR detectability was assessed using the MOCR% across-subject/within-subject variance ratio. The ratio in experiment 1 for linear-mode clicks was higher (8.0) than for nonlinear-mode chirps (6.4). The ratio for linear-mode clicks (8.9) in experiment 2 was slightly higher than for the comparable linear-mode stimulus (8.0) in experiment 1. TEOAEs showed excellent reliability with high signal-to-noise ratios in both experiments, but reliability was higher for linear-mode clicks than nonlinear-mode chirps. MOCR reliability for the two stimuli was comparable. The FPL pressure response retest reliability derived from the SPL at the microphone was higher than the SPL retest reliability across 0.4 to 8 kHz. Stable results required 2 to 3 trial pairs for the linear-mode click (experiments 1 and 2) and three for the nonlinear-mode chirp (experiment 1), taking around 2 min on average. CONCLUSIONS: The linear-mode click assay produced measurable, reliable, and stable TEOAE and MOCR results on both hardware platforms in around 2 min per ear. The stimulus design and response window ensured that any stimulus artifact in linear mode was unlikely to confound the results. The refined assay is ready to produce high-quality data quickly for clinical and field studies to develop population norms, recognize diagnostic patterns, and determine risk profiles.


Assuntos
Audição , Emissões Otoacústicas Espontâneas , Adulto , Humanos , Reprodutibilidade dos Testes , Emissões Otoacústicas Espontâneas/fisiologia , Cóclea/fisiologia , Reflexo , Estimulação Acústica/métodos
2.
Ear Hear ; 31(5): 599-610, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20520553

RESUMO

OBJECTIVES: To develop normative data for wideband middle-ear reflectance in a newborn hearing-screening population and to compare test performance with 1-kHz tympanometry for prediction of otoacoustic emission (OAE) screening outcome. DESIGN: Wideband middle-ear reflectance (using both tone and chirp stimuli from 0.2 to 6 kHz), 1-kHz tympanometry, and distortion-product (DP) OAEs were measured in 324 infants at two test sites. Ears were categorized into DP pass and DP refer groups. RESULTS: Normative reflectance values were defined over various frequency regions for both tone and chirp stimuli in ambient pressure conditions, and for reflectance area indices integrated over various frequency ranges. Receiver operating characteristic analyses showed that reflectance provides the best discriminability of DP status in frequency ranges involving 2 kHz and greater discriminability of DP status than 1-kHz tympanometry. Repeated-measures analyses of variance established that (a) there were significant differences in reflectance as a function of DP status and frequency but not sex or ear; (b) tone and chirp stimulus reflectance values are essentially indistinguishable; and (c) newborns from two geographic sites had similar reflectance patterns above 1 kHz. Birth type and weight did not contribute to differences in reflectance. CONCLUSIONS: Referrals in OAE-based infant hearing screening were strongly associated with increased wideband reflectance, suggesting middle-ear dysfunction at birth. Reflectance improved significantly during the first 4 days after birth with normalization of middle-ear function. Reflectance scores can be achieved within seconds using the same equipment used for OAE screening. Newborns with high reflectance scores at stage I screening should be rescreened within a few hours to a few days, because most middle-ear problems are transient and resolve spontaneously. If reflectance and OAE are not passed upon stage II screening, referral to an otologist for ear examination is suggested along with diagnostic testing. Newborns with normal reflectance and a refer result for the OAE screen should be referred immediately to an audiologist for diagnostic testing with threshold auditory brainstem response because of higher risk for permanent hearing loss.


Assuntos
Transtornos da Audição/diagnóstico , Testes Auditivos/métodos , Testes Auditivos/normas , Triagem Neonatal/métodos , Triagem Neonatal/normas , Testes de Impedância Acústica , Estimulação Acústica/métodos , Orelha Média/fisiologia , Feminino , Transtornos da Audição/fisiopatologia , Humanos , Recém-Nascido , Masculino , Emissões Otoacústicas Espontâneas , Valores de Referência