Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Med Case Rep ; 15(1): 83, 2021 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-33618738

RESUMO

BACKGROUND: The risk of stroke after carotid sinus massage is greater if there is preexisting carotid stenosis or carotid plaques. We present the case of a patient with underlying 40% carotid stenosis, who developed a watershed stroke after a self-neck massage in our stroke unit. We show a well-documented case with magnetic resonance images before and after the neck massage. We report a case of a watershed brain infarct after a self-massage of the carotid sinus, with preexisting carotid artery stenosis. Neck massage continues to be a significant cause of stroke and should therefore not be performed by patients. Clinicians must be aware of the implications of a carotid sinus massage in both the outpatient and inpatient settings. CASE PRESENTATION: We admitted a 58-year-old white male patient, with no relevant medical history, to our department with a brain stem infarct. During his stay at our stroke unit, the patient performed a self-neck massage with consecutive bradycardia and asystole, resulting in left-side hemiparesis. The underlying cause of the hemodynamic stroke is believed to be secondary to this intensive neck massage performed by the patient. The patient also suffered from unknown right internal carotid artery stenosis. CONCLUSION: Clinicians and patients must be aware that neck massage can lead to ischemic stroke. We postulate that repetitive impaired cardiac output can lead to a hemodynamic (watershed-type) stroke.


Assuntos
Isquemia Encefálica/etiologia , Seio Carotídeo , AVC Isquêmico/etiologia , Massagem/efeitos adversos , Infartos do Tronco Encefálico/etiologia , Estenose das Carótidas/diagnóstico por imagem , Eletrocardiografia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
2.
Clin Res Cardiol ; 101(1): 45-53, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21931964

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) represents a novel option for elderly with severe aortic valve stenosis who are denied surgical aortic valve replacement due to high perioperative risk. While transfemoral TAVI generally is being performed in general anesthesia (GA), TAVI under local anesthesia plus mild sedation (LAPS) might be an effective and safe alternative. METHODS: In a single-centre analysis, we assessed clinical data, preoperative risk scores (STS-Score), echocardiography, periprocedural data and labor costs in 74 patients undergoing transfemoral TAVI under GA (n = 33) and LAPS (n = 41). RESULTS: Patients who underwent TAVI in LAPS presented significantly more often with pulmonary hypertension and impaired renal function, and tended to have a higher STS score and more severe symptoms (higher NYHA class) versus the GA group. There were no significant differences in procedure-related 30-day mortality or complications between groups. The peak systolic and mean central aortic pressure were significantly higher in the LAPS group, while at the same time these patients required significantly less often periprocedural adrenergic support. Intervention time was shorter in the LAPS group due to avoidance of surgical cut-down of the access site. Moreover, total procedure time was significantly shorter and labor costs were lower in the LAPS group. Patients who underwent TAVI in LAPS could be mobilized significantly earlier. CONCLUSION: Our study indicates that TAVI under LAPS is as effective and safe as TAVI under GA. Furthermore, total procedure time, intervention time and labor costs could be reduced by LAPS. Mobilization of patients could be achieved earlier. We therefore consider LAPS to be favorable in patients undergoing transfemoral TAVI.


Assuntos
Anestesia Geral/métodos , Anestesia Local/métodos , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Idoso de 80 Anos ou mais , Anestesia Geral/efeitos adversos , Anestesia Local/efeitos adversos , Cateterismo Cardíaco/métodos , Feminino , Artéria Femoral , Seguimentos , Custos de Cuidados de Saúde , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/economia , Humanos , Hipertensão Pulmonar/epidemiologia , Masculino , Complicações Pós-Operatórias/epidemiologia , Insuficiência Renal/epidemiologia , Fatores de Tempo
3.
Int J Cardiol ; 133(1): 51-4, 2009 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-18237792

RESUMO

BACKGROUND: Syncope is a frequent diagnosis and establishing the etiology is often elaborate. Aim of this study was to evaluate the diagnostic value of NT-pro-BNP in patients with syncope. METHODS: NT-pro-BNP was assessed in 61 patients admitted for syncope to our cardiological department of the University hospital Cologne, Germany. RESULTS: 16 patients (26.2%) had neurally-mediated syncope, 9 (14.8%) had orthostatic syncope, 12 (19.7%) had cardiac arrhythmias, 8 (13.1%) had structural cardiac/cardiopulmonary disease, 2 patients (3.3%) had cerebrovascular disease, 3 (4.9%) had non-syncopal attack and in 11 (18%) patients the cause remained unknown. Patients with cardiac syncope had significantly higher NT-pro-BNP values (514 IQR 286-1154 pg/ml) than patients with non-cardiac cause (182 IQR 70-378 pg/ml, p=0.001). NT-pro-BNP at a cut-off of 164 pg/ml identified patients with cardiac syncope and patients requiring interventional cardiological therapy with a sensitivity of 90% and 93.8%, a specificity of 48.8% and 46.7% and a negative predictive value of 91% and 95.5%. NT-pro-BNP pre-testing could save 45% of the Holter ECGs, 83% of the telemetry monitoring, 47% of stress tests, 49% of echocardiographies, 67% of coronary angiographies and 43% of electrophysiological examinations. CONCLUSIONS: NT-pro-BNP assessment was helpful in differentiating cardiac from non-cardiac syncope. Further studies are needed to define the role of NT-pro-BNP in the diagnostic algorithm of syncope.


Assuntos
Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Síncope/diagnóstico , Síncope/etiologia , Idoso , Biomarcadores/sangue , Angiografia Coronária , Diagnóstico Diferencial , Ecocardiografia , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Serviço Hospitalar de Emergência , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Curva ROC , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Telemetria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA