Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Bone Metab ; 30(3): 209-217, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37718899

RESUMO

As the aging population increases, the number of patients with osteoporosis is gradually rising. Osteoporosis is a metabolic bone disease characterized by low bone mass and the microarchitectural deterioration of bone tissue, resulting in reduced bone strength and an increased risk of low-energy or fragility fractures. Thus, the use of anti-resorptive agents, such as bisphosphonates (BPs), to prevent osteoporotic fractures is growing annually. BPs are effective in reducing hip and other fractures. However, the longer a patient takes BPs, the higher the risk of an atypical femoral fracture (AFF). The exact mechanism by which long-term BP use affects the development of AFFs has not yet been clarified. However, several theories have been suggested to explain the pathogenesis of AFFs, such as suppressed bone remodeling, impaired bone healing, altered bone quality, and femoral morphology. The management of AFFs requires both medical and surgical approaches. BPs therapy should be discontinued immediately, and calcium and vitamin D levels should be evaluated and supplemented if insufficient. Teriparatide can be used for AFFs. Intramedullary nailing is the primary treatment for complete AFFs, and prophylactic femoral nailing is recommended if signs of an impending fracture are detected.

2.
J Bone Miner Res ; 38(9): 1268-1277, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37338940

RESUMO

Postoperative hypoparathyroidism (PO-hypoPT) is an uncommon complication of total thyroidectomy in thyroid cancer patients. Although long-term hypoPT causes characteristic changes in bone metabolism, the risk of fractures in hypoPT remains inconclusive. We investigated the risk of fractures in Korean thyroid cancer patients with PO-hypoPT. This was a retrospective cohort study using data from the Korea Central Cancer Registry and Korean National Health Insurance Service. We analyzed 115,821 thyroid cancer patients aged ≥18 years, who underwent total thyroidectomy between 2008 and 2016. The risk of any fractures, including vertebral, hip, humerus, and wrist fractures, according to parathyroid function after total thyroidectomy, was analyzed using the multivariable Cox proportional hazard model. The PO-hypoPT and preserved parathyroid function groups included 8789 (7.6%) and 107,032 (92.4%) patients, respectively. Over a mean follow-up duration of 4.8 years, 159 (1.8%) and 2390 (2.2%) fractures occurred in the PO-hypoPT and preserved parathyroid function groups, respectively. The risk of any fractures was significantly lower in the PO-hypoPT group than in the preserved parathyroid function group (hazard ratio [HR] = 0.83; 95% confidence interval [CI] 0.70-0.98; p = 0.037) after adjusting for confounders. Regarding the fracture site, only the risk of vertebral fractures was significantly lower in the PO-hypoPT group compared with the preserved parathyroid function group (HR = 0.67; 95% CI 0.47-0.96; p = 0.028) after adjusting for confounders. Subgroup analyses showed that bone mineral density measurements and calcium supplementation interacted with the relationship between PO-hypoPT and the risk of any fractures (p for interactions = 0.010 and 0.017, respectively). PO-hypoPT was associated with a lower risk of fractures in thyroid cancer patients, especially at the vertebra. The relatively low bone turnover caused by PO-hypoPT and appropriate management for PO-hypoPT with active vitamin D and calcium may prevent the deterioration of skeletal health in thyroid cancer patients who can easily be exposed to long-term overtreatment with levothyroxine. © 2023 American Society for Bone and Mineral Research (ASBMR).


Assuntos
Fraturas Ósseas , Hipoparatireoidismo , Neoplasias da Glândula Tireoide , Humanos , Adolescente , Adulto , Cálcio , Estudos de Coortes , Estudos Retrospectivos , Hipoparatireoidismo/complicações , Hipoparatireoidismo/epidemiologia , Fraturas Ósseas/complicações , Fraturas Ósseas/epidemiologia , Neoplasias da Glândula Tireoide/complicações , Neoplasias da Glândula Tireoide/epidemiologia , Neoplasias da Glândula Tireoide/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , República da Coreia/epidemiologia
3.
J Bone Metab ; 29(4): 205-215, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36529863

RESUMO

Adequate vitamin D status is essential for bone health. New randomized controlled trials investigating the effect of vitamin D supplementation on bone health have recently been published. This position statement updates and expands on the previous 2015 position statement of the Korean Society for Bone and Mineral Research on the adequate vitamin D status for healthy older adults (age ≥ 70 years) and those at high risk of osteoporosis and fracture (adults on osteoporosis medications) to maintain serum 25-hydroxy-vitamin D (25[OH]D) levels ≥ 20 ng/mL but < 50 ng/mL. A serum 25(OH)D level of 30 ng/mL may be beneficial for those on anti-resorptives. Vitamin D can be obtained from ultraviolet light exposure and diet. To reach the target vitamin D status through intake, adults must consume at least 400 IU/day to reach 20 ng/mL and 800 to 1,000 IU/day to reach 30 ng/mL. Foods familiar to the Korean diet that are high in vitamin D content or consumed frequently enough to positively impact vitamin D status are introduced in addition to the amount required to help reach one's target vitamin D status.

4.
J Bone Joint Surg Am ; 104(Suppl 2): 68-75, 2022 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-34780390

RESUMO

BACKGROUND: Long-term follow-up results of ceramic-on-ceramic (COC) total hip arthroplasty (THA), specifically, in patients with osteonecrosis of the femoral head (ONFH) are unknown. We evaluated (1) clinical results and radiological outcomes, (2) ceramic-related complications: noise and ceramic fracture, (3) osteolysis, and (4) survivorship after alumina COC THA in ONFH patients with longer than 10-year follow-up. METHODS: From May 2003 to June 2009, 325 ONFH patients (403 hips) underwent primary THAs at our department. Among them, 231 patients (293 THAs) were followed for 10 to 16 (mean, 12.9) years. There were 148 men and 83 women, their mean age at the time of THA was 47.2 years, and their mean body index was 24.0 kg/m2. The postoperative CT scans were done in 160 hips. RESULTS: Grinding sensation or squeak was noted in 6.8% (20/293), ceramic head fracture occurred in 2.4% (7/293) and acetabular osteolysis developed in 0.7% (2/293). All 7 ceramic fractures occurred in 28-mm short-neck heads. There was no detectable wear or prosthetic loosening, and the 16-year survivorship was 96.0% (95% confidence interval; 93.8% to 98.2%). The mean Harris hip score was 91.7 (range, 84 to 100) points at the final follow-up. CONCLUSIONS: The 10- to 16-year results of alumina COC THAs were encouraging with an excellent survivorship. However, ceramic fracture and noise still remain matters of concern. We recommend not to use 28-mm short-neck ceramic head to avoid ceramic head fractures. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Osteonecrose , Óxido de Alumínio , Artroplastia de Quadril/métodos , Cerâmica , Feminino , Cabeça do Fêmur , Seguimentos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Resultado do Tratamento
5.
J Hand Surg Am ; 46(11): 1026.e1-1026.e7, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33867200

RESUMO

PURPOSE: To develop and validate identification criteria for distal radius fractures (DRFs) and their treatment using a national health insurance database. METHODS: Patients who had at least 1 wrist radiograph taken in 2018 were recruited from a single academic referral hospital. After excluding patients who lacked immobilization code for wrist pathology, we collected data on the overall population. Because some patients might have undergone wrist radiography at another institution or had DRFs without an immobilization code, we additionally included patients who had a DRF diagnosis code at our institution. Reviews of medical records and wrist radiographs were considered for the diagnosis of DRF. We evaluated the sensitivity, specificity, and positive predictive value (PPV) of 3 operational definitions of fractures that were based on a single primary or secondary diagnosis code; all diagnosis codes, including primary and secondary codes; and all diagnosis and procedure codes. RESULTS: Among 768 patients included in the study, true DRFs were confirmed in 305. The sensitivity, specificity, and PPV for definition 1 were 91.5% (95% CI, 88.3%-94.6%), 97.5% (95% CI, 95.9%-99.1%), and 96.9% (95% CI, 94.9%-98.9%), respectively. Although the sensitivity of definition 2 was higher (92.1%; 95% CI, 89.1%-95.2%), its specificity and PPV were lower (96.4% [95% CI, 94.4%-98.3%] and 95.6% [95% CI, 93.2%-97.9%], respectively). The sensitivity of definition 3 was the lowest (88.2%; 95% CI, 84.6%-91.8%), but its specificity and PPV were the highest among the 3 definitions (98.6% [95% CI, 97.4%-98.8%] and 98.2% [95% CI, 96.6%-99.8%], respectively). CONCLUSIONS: Patients with DRFs can be identified from claims databases with high accuracy using an operational definition based on DRF diagnosis and procedure codes, including codes for surgical and nonoperative methods. CLINICAL RELEVANCE: Verified operational definitions will increase the consistency of results in future national health insurance database studies related to DRFs.


Assuntos
Fraturas do Rádio , Bases de Dados Factuais , Humanos , Programas Nacionais de Saúde , Valor Preditivo dos Testes , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/epidemiologia , Projetos de Pesquisa
6.
Spine J ; 20(2): 225-233, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31589928

RESUMO

BACKGROUND CONTEXT: Vertebral fracture is related to an increased risk for subsequent and recurrent osteoporotic fracture as well as increased mortality. However, no study has investigated the exact incidence and mortality of subsequent vertebral fractures. OBJECTIVE: The purpose of our study was to determine trends in the incidence and mortality of subsequent vertebral fractures after first-time vertebral fracture in Koreans older than 50 years using the national claims database. STUDY DESIGN: Retrospective cohort study. PATIENT SAMPLE: Data from the Korea National Health Insurance Service database from 2007 to 2016. OUTCOME MEASURES: The incidence of subsequent vertebral fracture during a 4-year follow-up period. The mortality and standardized mortality ratio (SMR) after subsequent vertebral fractures during the 1-year period after fracture were also determined. Analysis was restricted to patients older than 50 years. METHODS: The national claims data set was analyzed to find all new visits and revisits after 6 months from the last claim to a hospital or clinic for vertebral fractures and revisits in men and women aged 50 years or older between 2007 and 2016. The number of first-time vertebral fractures in 2012 was investigated to determine subsequent vertebral fractures. The incidence, mortality rates, and SMR of subsequent vertebral fractures were calculated. There were no sources of funding and no conflicts of interest associated with this study. RESULTS: During the 4-year follow-up period, the overall cumulative incidence of subsequent vertebral fractures were 27.53%. According to sex, the cumulative incidence of subsequent vertebral fractures was 20.09% in men and 29.98% in women. The cumulative mortality rate over the first year after subsequent vertebral fractures was 5%. The mortality rates over 1 year were 10.04% for men and 3.81% for women. The overall SMR at the 1-year follow-up after subsequent vertebral fractures was 10.58 (95% confidence interval: 9.29-12.05) in men and 3.88 (95% confidence interval: 3.5-4.3) in women. CONCLUSIONS: Our study showed that subsequent vertebral fractures were more common in women, with an incidence rate of 29.98% over 4 years. However, the mortality rate was higher in men, reaching 10.04% in 1 year. Subsequent vertebral fractures occurred in large numbers, and the mortality rates were relatively high. Thus, first vertebral fracture may be considered as an early warning of high risk for future subsequent vertebral fractures, especially in women.


Assuntos
Fraturas por Osteoporose/epidemiologia , Fraturas da Coluna Vertebral/epidemiologia , Demandas Administrativas em Assistência à Saúde/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Programas Nacionais de Saúde/estatística & dados numéricos , Fraturas por Osteoporose/mortalidade , República da Coreia , Fraturas da Coluna Vertebral/mortalidade
7.
Clin Orthop Surg ; 11(3): 265-269, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31475045

RESUMO

BACKGROUND: Hip fracture surgery (HFS) is often associated with perioperative blood loss, and it frequently necessitates transfusion. However, the hemoglobin (Hb) threshold for transfusion remains controversial in hip fracture patients. We evaluated the usefulness of the restrictive strategy and preoperative intravenous iron supplementation in HFS. METHODS: We retrospectively reviewed the medical records of 1,634 patients (> 60 years of age) who underwent HFS between May 2003 and June 2014 and were followed up for 1 year or more after surgery. We used the liberal transfusion strategy until May 2009 to determine the transfusion threshold; afterwards, we switched to the restrictive transfusion strategy. Patients with the restrictive transfusion strategy (restrictive group) received intravenous iron supplementation before surgery. We compared the transfusion rate, morbidity, and mortality of the restrictive group with those of the patients with the liberal transfusion strategy (liberal group). RESULTS: Preoperative intravenous iron supplementation was not associated with any adverse reactions. The transfusion rate was 65.3% (506/775) in the liberal group and 48.2% (414/859) in the restrictive group (p < 0.001). The mean hospital stay was shorter in the restrictive group (21.5 vs. 28.8 days, p < 0.001). There was no significant difference in the postoperative medical complications including myocardial infarction and cerebrovascular event. Mortality at postoperative 30, 60, and 90 days was similar between the two groups. CONCLUSIONS: Our blood management protocol involving restrictive strategy combined with preoperative intravenous iron supplementation appears to be effective and safe in HFS of elderly patients.


Assuntos
Anemia/terapia , Transfusão de Sangue/normas , Fraturas do Quadril/cirurgia , Compostos de Ferro/administração & dosagem , Administração Intravenosa , Idoso , Idoso de 80 Anos ou mais , Anemia/etiologia , Perda Sanguínea Cirúrgica , Suplementos Nutricionais , Feminino , Hemoglobinas/análise , Fraturas do Quadril/sangue , Humanos , Masculino , Procedimentos Ortopédicos , Hemorragia Pós-Operatória/terapia , Cuidados Pré-Operatórios , Estudos Retrospectivos
8.
Calcif Tissue Int ; 101(6): 623-630, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28913546

RESUMO

The purpose of this study was to estimate the current economic burden of osteoporosis in South Korea using national claim data of the Korean National Health Insurance Service (KNHIS) from 2008 to 2011. Patients aged 50 years or older were identified from KNHIS nationwide database for all records of outpatient visits or hospital admissions. Healthcare costs for osteoporotic patients included direct medical costs for hospitalization, outpatient care, and prescription drugs for the year after discharge. Healthcare costs were estimated based on the perspective of KNHIS, and calculated using a bottom-up approach. Between 2008 and 2011, total healthcare costs for osteoporotic patients increased from 3976 million USD to 5126 million USD, with an annual increase of 9.2% which accounted for one-sixth (16.7%) of national healthcare expenditure. Healthcare cost for hospitalization was the highest ($1903 million, 40.0% of total healthcare cost), followed by cost for outpatient care ($1474 million, 31.0%) and cost for prescription drugs ($1379 million, 29.0%). Although total healthcare cost for osteoporotic men was 6 times lower than that for osteoporotic women, the cost per person was 1.5 times higher than that for women. Total healthcare cost for osteoporotic patients without fractures was higher than that for osteoporotic patients with fractures. However, cost per person was the opposite. Osteoporosis entails substantial epidemiologic and economic burden in South Korea. This study provides information about the total healthcare burden, which could be important when determining what attention and awareness osteoporosis should be given in the public health system.


Assuntos
Efeitos Psicossociais da Doença , Osteoporose/economia , Idoso , Feminino , Custos de Cuidados de Saúde/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Programas Nacionais de Saúde , República da Coreia
9.
Hip Pelvis ; 29(2): 81-90, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28611958

RESUMO

The volume of hip arthroplasty is stiffly increasing because of excellent clinical outcomes, however it has not been shown to decrease the incidence of transfusions due to bleeding related to this surgery. This is an important consideration since there are concerns about the side effects and social costs of transfusions. First, anemia should be assessed at least 30 days before elective hip arthroplasty, and if the subject is diagnosed as having anemia, an additional examination of the cause of the anemia should be carried and steps taken to address the anemia. Available iron treatments for anemia take 7 to 10 days to facilitate erythropoiesis, and preoperative iron supplementation, either oral or intravenous, is recommended. When using oral supplements for iron storage, administer elemental iron 100 mg daily for 2 to 6 weeks before surgery, and calculate the dose using intravenous supplement. Tranexamic acid (TXA) is a synthetic derivative of the lysine component, which reduces blood loss by inhibiting fibrinolysis and clot degradation. TXA is known to be an effective agent for reducing postoperative bleeding and reducing the need for transfusions in primary and revision total hip arthroplasties. Patient blood management has improved the clinical outcome after hip arthroplasty through the introduction and research of various agents, thereby reducing the need for allogeneic blood transfusions and reducing the risk of transfusion-related infections and the duration of hospitalizations.

10.
J Arthroplasty ; 30(3): 411-5, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25449586

RESUMO

Ceramic-on-ceramic articulation has the lowest wear with little osteolysis. However, the wear and osteolysis in long-term follow-up are not known. Another concern is ceramic fracture, which might occur after repeated stress during a long period. Ninety hips (76 patients with a mean age of 47 years) that underwent cementless total hip arthroplasty using third-generation ceramic-on-ceramic articulation were followed for 14-16 years. At final follow-up, there was no measurable ceramic wear and no periprosthetic osteolysis was identified. No ceramic fracture occurred during the follow-up. One hip was revised because of late infection. All prostheses were bone-ingrown. Two patients experienced a grinding sensation. However, no patient had squeak. The mean Harris hip score at the final evaluation was 89 points and the survival rate was 98.9%.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Artropatias/cirurgia , Adulto , Idoso , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Materiais Biocompatíveis , Cerâmica , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
11.
J Bone Metab ; 21(2): 143-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-25006571

RESUMO

BACKGROUND: In management of osteoporosis, several concerns here have been raised. The current issue included the utilization of dual energy X-ray absorptiometry (DXA) and fracture-risk assessment (FRAX), screening of vitamin D deficiency and secondary osteoporosis, and long-term use of bisphosphonate and calcium supplements. There was no study on physicians' attitude on these current issues in Korea. Therefore, we investigated the physicians' attitude on these issues by survey. METHODS: We administered a 30-item questionnaire to all members of Korean Society for Bone and Mineral Research by email survey form. One hundred participants answered the questionnaire. The questionnaire included the questions about the physicians' attitude to current issues and the barriers to osteoporosis treatment in Korea. RESULTS: Most physicians used bone densitometry devices (99%) and, central DXA was the most accessible device (95%). Eighty-eight percent were aware of FRAX®, but among them, only 19.3% used it. The main reason for not using FRAX® was the lack of time in their proactive (76%). Screening for vitamin D status and secondary osteoporosis was performed by 59% and 52% of the respondents, respectively. The lack of awareness among patients and high costs of medication were perceived as the most important barriers to osteoporosis management in Korea. CONCLUSIONS: This study provides physicians' perspective to the current issue for diagnostic and treatment of osteoporosis in Korea. To further improve osteoporosis management, educational programs for patients and doctors, and the improvement of reimbursement system should be considered in Korea.

12.
J Arthroplasty ; 29(12): 2412-4, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24704123

RESUMO

Seventy-nine patients (94 hips), who underwent cementless alumina-on-alumina total hip arthroplasty (THA) with the use of a 36-mm delta ceramic liner-on-alumina ceramic femoral head, were followed for an average of 6.5years (range, 5-7.7years). All acetabular and femoral components were bone-ingrown and neither pelvic nor femoral osteolysis was identified until the latest follow-up. The survivorship with revision surgery as an endpoint was 97.9% (95% confidence interval=100%-95%). Ceramic related complications such as fracture and squeaking did not occur in any patient. The mid-term results of cementless THA with this type of ceramic articulation are encouraging.


Assuntos
Artroplastia de Quadril/efeitos adversos , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Artropatias/cirurgia , Adulto , Idoso , Óxido de Alumínio , Materiais Biocompatíveis , Cerâmica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Amplitude de Movimento Articular , Resultado do Tratamento , Adulto Jovem
13.
J Bone Metab ; 20(2): 99-103, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24524065

RESUMO

BACKGROUND: Calcium is prescribed worldwide for patients diagnosed with osteoporosis. However, the national utilization of calcium and compliance with calcium is unclear in Korea. Our purpose is to evaluate Korea's national utilization of calcium and compliance with calcium in patients with osteoporotic hip fracture from 2007 to 2010 using data from the Health Insurance Review and Assessment (HIRA) Service. METHODS: From 2007 to 2011, osteoporotic hip fractures were identified using the International Classification of Diseases, 10th revision (ICD-10) and procedure code form from the nationwide database of the Health Insurance Review and Assessment Service. Compliant users of calcium were defined as the patients' medication possession ratio of 80 or more. We analyzed the compliance of calcium according to age and gender. RESULTS: Among 85,228 patients with hip fracture, 20,800 patients (24.4%) received a prescription of a calcium supplement. Among them, only 1,692 patients (8.1%) were identified as compliant users of calcium. The proportion of compliant users was higher in women than men in all age groups. The proportion of compliant users decreased with age in women. CONCLUSIONS: In Korea, the national utilization of calcium was low and compliance with calcium was unsatisfactory even in patients with osteoporotic hip fracture.

14.
Arch Orthop Trauma Surg ; 133(3): 413-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23212650

RESUMO

PURPOSE: In an alumina-on-alumina total hip arthroplasty (THA), recommended with a small inclination angle <45°, the acetabular component (cup) may be positioned more medially to be covered almost completely by host bone. The purpose of this study was to identify the correlating factors and to evaluate the outcomes of medial placement of the cup in patients with alumina-on-alumina THAs. METHODS: Using the propensity score matching with age, gender, body mass index, initial diagnosis, and the length of follow-up as variables, 38 hips with a medialized cup and 38 hips with a non-medialized one were identified from 389 hips in 347 who patients underwent primary alumina-on-alumina THA and followed up for more than 7 years. Clinical and radiological outcomes were compared between the two groups. RESULTS: Preoperative acetabular medial wall thickness and the cup inclination angle were significantly smaller in the medialization group compared to the non-medialization group. Center edge angle, cup size, and coverage by host bone were not significantly different between the two groups. The hip center of rotation was significantly medialized in the medialization group. The Harris hip scores were not significantly different between the two groups. No component loosening or osteolysis was observed and no revision was required in either groups. CONCLUSIONS: Thin acetabular medial wall and a small inclination angle of the cup were the correlating factors of medial placement of the cup in patients who underwent an alumina-on-alumina THA. Medial placement did not lead to differences in the clinical or radiological outcomes.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Próteses Articulares Metal-Metal , Osteoartrite do Quadril/cirurgia , Adolescente , Adulto , Idoso , Óxido de Alumínio , Artroplastia de Quadril/instrumentação , Materiais Biocompatíveis , Feminino , Articulação do Quadril , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Desenho de Prótese , Adulto Jovem
15.
J Arthroplasty ; 28(1): 132-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23164837

RESUMO

We evaluated the outcomes of 64 consecutive revision total hip arthroplasties with an alumina-on-alumina bearing surface in 61 patients with osteolysis. No implants had been rerevised nor was osteolysis detected at a mean of 9.8 years (range, 7.0-13.1 years) postoperatively. There was 1 case of stem loosening but no cup loosening or alumina bearing fractures. Two surgical procedures were performed for an infection in 1 patient. Three dislocations occurred in 3 hips; all were treated with closed reduction and abduction bracing for 3 months. No further dislocations occurred. With any reoperation or radiographic evidence of osteolysis or loosening as the end point, the 7-year survival rate was 96.9% (95% confidence interval, 90.8%-100%). The alumina-on-alumina bearing surfaces used for revision total hip arthroplasty in patients with osteolysis were found to produce encouraging clinical results and implant survival rates at a minimum of 7 years postoperatively.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril , Prótese de Quadril , Osteólise/cirurgia , Adulto , Idoso , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação , Adulto Jovem
16.
J Bone Joint Surg Am ; 92(8): 1715-9, 2010 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-20660234

RESUMO

We previously reported the five-to-six-year results of the use of third-generation alumina-on-alumina bearings in a consecutive series of 100 primary cementless total hip arthroplasties. This report presents the longer-term outcomes of these same bearings, at a minimum of ten years postoperatively. Eighty-six of eighty-eight hips available for the study retained the original bearings at the time of the latest follow-up. Thirteen hips were associated with noise, and six hips demonstrated fretting of the femoral neck on radiographs. Two hips required a change of the bearings because of a ceramic head fracture. The ten-year survival rate of the alumina-on-alumina total hip prostheses, with revision of any implant for any reason as the end point, was 99.0%. On the basis of those results, we concluded that the rate of survival of primary cementless total hip prostheses with third-generation alumina-on-alumina bearings is excellent at ten years. However, the risk of ceramic fracture, noise, and impingement between the metal neck and the ceramic liner should be a concern to surgeons, and patients should be informed of these risks before surgery.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artropatias/cirurgia , Adolescente , Adulto , Idoso , Óxido de Alumínio , Materiais Biocompatíveis , Feminino , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA