RESUMO
BACKGROUND: It is rare for newly diagnosed (de novo) or newly treated acute myeloid leukemia (AML) complicated with thrombotic complications, especially combined arterial and venous thrombosis. METHODS: We reported a 13-year-old boy diagnosed with AML and leukocytosis, who developed right femoral vein and right dorsal artery thrombosis during chemotherapy. After treatment with low molecular weight heparin, diosmin, and alprostadil, symptoms were relieved. Unfortunately, the child suffered from coagulopathy afterward, which was unexpectedly caused by vitamin K deficiency. RESULTS: After supplementation with vitamin K and prothrombin complex concentrate, coagulation function recovered. CONCLUSION: For childhood AML patients with high thrombotic risks, close monitoring during anticoagulant treatment was necessary. Concomitantly, we should be alert to past medication history and combined medication use, especially those that may lead to vitamin K deficiency, secondary bleeding, and coagulation disorders. Rational use of antibiotics, anticoagulants, and antitumor drugs must be guaranteed.
Assuntos
Transtornos da Coagulação Sanguínea , Leucemia Mieloide Aguda , Trombose , Deficiência de Vitamina K , Masculino , Humanos , Criança , Adolescente , Veia Femoral/patologia , Anticoagulantes , Trombose/etiologia , Transtornos da Coagulação Sanguínea/induzido quimicamente , Leucemia Mieloide Aguda/complicações , Leucemia Mieloide Aguda/tratamento farmacológico , Leucemia Mieloide Aguda/patologia , Deficiência de Vitamina K/complicações , ArtériasRESUMO
A simple and sensitive method for evaluating the chemical compositions of protein amino acids, including cystine (Cys)(2) and tryptophane (Try) has been developed, based on the use of a sensitive labeling reagent 2-(11H-benzo[alpha]-carbazol-11-yl) ethyl chloroformate (BCEC-Cl) along with fluorescence detection. The chromophore of the 1,2-benzo-3,4-dihydrocarbazole-ethyl chloroformate (BCEOC-Cl) molecule was replaced with the 2-(11H-benzo[alpha]-carbazol-11-yl) ethyl functional group, yielding the sensitive fluorescence molecule BCEC-Cl. The new reagent BCEC-Cl could then be substituted for labeling reagents commonly used in amino acid derivatization. The BCEC-amino acid derivatives exhibited very high detection sensitivities, particularly in the cases of (Cys)(2) and Try, which cannot be determined using traditional labeling reagents such as 9-fluorenyl methylchloroformate (FMOC-Cl) and ortho-phthaldialdehyde (OPA). The fluorescence detection intensities for the BCEC derivatives were compared to those obtained when using FMOC-Cl and BCEOC-Cl as labeling reagents. The ratios I (BCEC)/I (BCEOC) = 1.17-3.57, I (BCEC)/I (FMOC) = 1.13-8.21, and UV(BCEC)/UV(BCEOC) = 1.67-4.90 (where I is the fluorescence intensity and UV is the ultraviolet absorbance). Derivative separation was optimized on a Hypersil BDS C(18) column. The detection limits calculated from 1.0 pmol injections, at a signal-to-noise ratio of 3, ranged from 7.2 fmol for Try to 8.4 fmol for (Cys)(2). Excellent linear responses were observed, with coefficients of >0.9994. When coupled with high-performance liquid chromatography, the method established here allowed the development of a highly sensitive and specific method for the quantitative analysis of trace levels of amino acids including (Cys)(2) and Try from bee-collected pollen (bee pollen) samples.