Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Zhonghua Yi Xue Za Zhi ; 101(30): 2370-2374, 2021 Aug 10.
Artigo em Chinês | MEDLINE | ID: mdl-34404129

RESUMO

Objective: To evaluate the efficacy and safety of giant emphysematous bulla (GEB) volume reduction via medical thoracoscope. Methods: This was a prospective, single-arm study conducted between July 2018 and September 2020 in Ri Zhao Hospital of Traditional Chinese Medicine. Patients who met the inclusion criteria were treated with GEB volume reduction via medical thoracoscope and were followed up to evaluate the efficacy and safety of the technique. According to comparison of preoperative and postoperative chest CT results, the self-designed evaluation criteria of imaging efficacy were as follows: complete or nearly complete disappearance of GEB (GEB volume reduction ≥90%), significant reduction of GEB (75%≤GEB volume reduction<90%), reduction of GEB (50%≤GEB volume reduction<75%) and no change (GEB volume reduction<50%). Results: A total of 47 patients were included, among whom 43 were males, with an age M (Q1, Q3) of 63.0 (55.0, 67.0). The CT results showed complete or nearly complete disappearance of GEB in 43 patients, significant reduction of GEB in 3 patients and reduction of GEB in 1 patient before discharge. The degree of dyspnea improved significantly (P<0.05). Arterial partial pressure of carbon dioxide (PaCO2) decreased from (48.2±8.4)mmHg (1 mmHg=0.133 kPa) to (45.4±7.3)mmHg (P<0.05). The 6-minute walk test (6MWT) increased from (245.6±162.4)m to (283.5±152.2)m (P<0.05). Six-month postoperative follow-up was completed in 24 patients, and CT results showed that the efficacy of volume reduction was continuous compared with that before discharge. GEB was further reduced or even disappeared in 3 of the cases. Besides, the degree of dyspnea, 6MWT (384.4±148.2)m and PaCO2 (42.7±6.6)mmHg were improved significantly (P<0.05). The oxygenation index (356.86±61.21)mmHg was significantly higher than that before surgery (295.20±67.16)mmHg and before discharge (294.50±76.69)mmHg (P<0.05). No perioperative deaths occurred. Conclusions: GEB volume can be completely eliminated or significantly reduced by this innovative technique, while PaCO2, the degree of dyspnea and exercise endurance can be significantly improved after operation. The 6-month follow-up after surgery showed that the above benefits continued, and that the oxygenation index improved significantly.


Assuntos
Enfisema Pulmonar , Toracoscópios , Vesícula , Gasometria , Humanos , Masculino , Estudos Prospectivos , Enfisema Pulmonar/cirurgia
2.
Zhonghua Jie He He Hu Xi Za Zhi ; 44(7): 619-623, 2021 Jul 12.
Artigo em Chinês | MEDLINE | ID: mdl-34256448

RESUMO

Objective: To explore the efficacy and safety of position selection in combination with intra-pleural thrombin injection in the treatment of persistent air leakage (PAL) after medical thoracoscopic treatment of bullous pulmonary-pleural diseases (e.g. spontaneous pneumothorax or giant emphysematous bulla). Methods: This was a prospective study conducted in Rizhao Hospital of Traditional Chinese Medicine from August 2018 to November 2020. Twenty patients(19 males,1 female) with a mean age of (62.3±8.1) years met the diagnostic criteria for PAL which was defined as the air leak persisted more than 3 days despite of the closed thoracic drainage after medical thoracoscopic treatment of bullous pulmonary-pleural diseases.They received the following treatment procedures (referred to as "position plus"):①Pleural cavity injection (50% glucose 20 ml+thrombin 5 000 U).②Changing the patient's position under continuous negative pressure suction to find the position causing the complete stop or significant reduction of air leakage, and keeping in the position for 24-48 hours.③If the PAL wasn't stopped 48 hours later, the procedures above would be repeated.The duration of air leakage after "position plus", times of pleural cavity injection, condition of lung re-expansion, recurrence of air leakage and complications during hospitalization were recorded. Descriptive statistics were used to summarize the results:¯x±s or M(P25, P75) for continuous variables; frequency and percentages for categoric variables. Results: A total of 20 patients were included. The average duration of air leakage after"position plus" was (1.32±0.97) days. The times of pleural cavity injection required were 1.0(1.0, 1.0).All the patients showed good lung re-expansion in review of imaging after PAL was stopped. One patient had recurrent air leakage during hospitalization. No serious complications occurred. Conclusion: The comprehensive "position plus" intervention method is effective, safe and easily operating for the treatment of PAL after medical thoracoscopic treatment of bullous pulmonary-pleural diseases.


Assuntos
Pneumotórax , Trombina , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pleura/diagnóstico por imagem , Pleura/cirurgia , Pneumonectomia , Pneumotórax/diagnóstico por imagem , Pneumotórax/tratamento farmacológico , Pneumotórax/cirurgia , Complicações Pós-Operatórias/tratamento farmacológico , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA