Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Med Eng Phys ; 86: 47-56, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33261733

RESUMO

Spinal cord injury (SCI) often results in loss of the ability to keep the trunk erect and stable while seated. Functional neuromuscular stimulation (FNS) can cause muscles paralyzed by SCI to contract and assist with trunk stability. We have extended the results of a previously reported threshold-based controller for restoring upright posture using FNS in the sagittal plane to more challenging displacements of the trunk in the coronal plane. The system was applied to five individuals with mid-thoracic or higher SCI, and in all cases the control system successfully restored upright sitting. The potential of the control system to maintain posture in forward-sideways (diagonal) directions was also tested in three of the subjects. In all cases, the controller successfully restored posture to erect. Clinically, these results imply that a simple, threshold based control scheme can restore upright sitting from forward, lateral or diagonal leaning without a chest strap; and that removal of barriers to upper extremity interaction with the surrounding environment could potentially allow objects to be more readily retrieved from around the wheelchair. Technical performance of the system was assessed in terms of three variables: response time, recovery time and percent maximum deviation from erect. Overall response and recovery times varied widely among subjects in the coronal plane (415±213 ms and 1381±883 ms, respectively) and in the diagonal planes (530±230 ms and 1800±820 ms, respectively). Average response time was significantly lower (p < 0.05) than the recovery time in all cases. The percent maximum deviation from erect was of the order of 40% or less for 9 out of 10 cases in the coronal plane and 5 out of 6 cases in diagonal directions.


Assuntos
Terapia por Estimulação Elétrica , Traumatismos da Medula Espinal , Humanos , Equilíbrio Postural , Postura , Traumatismos da Medula Espinal/terapia , Tronco
2.
Spinal Cord Ser Cases ; 6(1): 86, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32934207

RESUMO

STUDY DESIGN: Single-subject repeated measures study. OBJECTIVES: Neuromuscular electrical stimulation (NMES) can enhance walking for people with partial paralysis from incomplete spinal cord injury (iSCI). This single-subject study documents an individual's experience who both received an experimental implanted NMES system and underwent clinical bilateral hinged total knee arthroplasty (TKA). She walked in the community with knee pain prior to either intervention. Walking performance improved with an implanted NMES system. Knee pain and instability continued to worsen over time and eventually required TKA. This study evaluates the effects of these interventions. SETTING: Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland OH, USA. METHODS: The differential and combined effects of NMES and hinged knee replacement were assessed in terms of walking speed, toe clearance, knee angle, and participant perceptions with and without stimulation assistance both before and after TKA. RESULTS: The combined approach both reduced pain and restored walking ability to levels achieved prior to developing significant knee pain that prevented walking without NMES. There was an interaction effect between NMES and TKA on walking speed. Toe clearance consistently improved with stimulation assistance and TKA prevented significant knee hyperextension. The greatest impact was on endurance. Knee replacement re-enabled long distance walking with the addition of stimulation again more than doubling her maximum walking distance from 214 to 513 m. CONCLUSIONS: These data support further research of combined implantable interventions that may benefit people with iSCI. Furthermore, joint laxity and pain may not necessarily be contraindications to NMES if addressed with conventional clinical treatments.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/fisiopatologia , Traumatismos da Medula Espinal/reabilitação , Caminhada/fisiologia , Estimulação Elétrica/métodos , Terapia por Estimulação Elétrica/métodos , Humanos , Próteses e Implantes
3.
Am J Phys Med Rehabil ; 99(12): e138-e141, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32149817

RESUMO

This case study evaluated the effect of implanted multijoint neuromuscular electrical stimulation gait assistance on oxygen consumption relative to walking without neuromuscular electrical stimulation after stroke. The participant walked slowly with an asymmetric gait pattern after stroke. He completed repeated 6-min walk tests at a self-selected walking speed with and without hip, knee, and ankle stimulation assistance. His walking speed with neuromuscular electrical stimulation more than doubled from 0.28 ± 0.01 m/sec to 0.58 ± 0.04 m/sec, whereas average step length and cadence increased by 0.12 m and 24 steps/min, respectively. As a result, energy cost of walking with neuromuscular electrical stimulation decreased by 0.19 ml O2/kg per meter as compared with walking without stimulation while oxygen consumption increased by 1.1 metabolic equivalent of tasks (3.9 ml O2/kg per minute). These metabolic demands are similar to those reported for stroke survivors capable of walking at equivalent speeds without stimulation, suggesting the increase in oxygen consumption and decreased energy cost result from improved efficiency of faster walking facilitated by neuromuscular electrical stimulation. Although the effect of neuromuscular electrical stimulation on gait economy has implications for community walking within the user's metabolic reserves, this case study's results should be interpreted with caution and the hypothesis that multijoint neuromuscular electrical stimulation improves metabolic efficiency should be tested in a wide population of stroke survivors with varied deficits.


Assuntos
Terapia por Estimulação Elétrica , Consumo de Oxigênio/fisiologia , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral/metabolismo , Acidente Vascular Cerebral/fisiopatologia , Caminhada/fisiologia , Idoso , Humanos , Articulações , Masculino , Acidente Vascular Cerebral/complicações
4.
J Neuroeng Rehabil ; 15(1): 17, 2018 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-29530053

RESUMO

BACKGROUND: The leading cause of injury for manual wheelchair users are tips and falls caused by unexpected destabilizing events encountered during everyday activities. The purpose of this study was to determine the feasibility of automatically restoring seated stability to manual wheelchair users with spinal cord injury (SCI) via a threshold-based system to activate the hip and trunk muscles with electrical stimulation during potentially destabilizing events. METHODS: We detected and classified potentially destabilizing sudden stops and turns with a wheelchair-mounted wireless inertial measurement unit (IMU), and then applied neural stimulation to activate the appropriate muscles to resist trunk movement and restore seated stability. After modeling and preliminary testing to determine the appropriate inertial signatures to discriminate between events and reliably trigger stimulation, the system was implemented and evaluated in real-time on manual wheelchair users with SCI. Three participants completed simulated collision events and four participants completed simulated rapid turns. Data were analyzed as a series of individual case studies with subjects acting as their own controls with and without the system active. RESULTS: The controller achieved 93% accuracy in detecting collisions and right turns, and 100% accuracy in left turn detection. Two of the three subjects who participated in collision testing with stimulation experienced significantly decreased maximum anterior-posterior trunk angles (p < 0.05). Similar results were obtained with implanted and surface stimulation systems. CONCLUSIONS: This study demonstrates the feasibility of a neural stimulation control system based on simple inertial measurements to improve trunk stability and overall safety of people with spinal cord injuries during manual wheelchair propulsion. Further studies are required to determine clinical utility in real world situations and generalizability to the broader SCI or other population of manual or powered wheelchair users. TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT01474148 . Registered 11/08/2011 retrospectively registered.


Assuntos
Terapia por Estimulação Elétrica/métodos , Equilíbrio Postural/fisiologia , Postura Sentada , Traumatismos da Medula Espinal , Cadeiras de Rodas , Acidentes por Quedas/prevenção & controle , Adulto , Fenômenos Biomecânicos , Pessoas com Deficiência , Desenho de Equipamento/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Cadeiras de Rodas/efeitos adversos
5.
J Spinal Cord Med ; 41(2): 165-173, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28155591

RESUMO

OBJECTIVE: Test the effect of a multi-joint control with implanted electrical stimulation on walking after spinal cord injury (SCI). DESIGN: Single subject research design with repeated measures. SETTING: Hospital-based biomechanics laboratory and user assessment of community use. PARTICIPANTS: Female with C6 AIS C SCI 30 years post injury. INTERVENTIONS: Lower extremity muscle activation with an implanted pulse generator and gait training. OUTCOME MEASURES: Walking speed, maximum distance, oxygen consumption, upper extremity (UE) forces, kinematics and self-assessment of technology. RESULTS: Short distance walking speed at one-year follow up with or without stimulation was not significantly different from baseline. However, average walking speed was significantly faster (0.22 m/s) with stimulation over longer distances than volitional walking (0.12 m/s). In addition, there was a 413% increase in walking distance from 95 m volitionally to 488 m with stimulation while oxygen consumption and maximum upper extremity forces decreased by 22 and 16%, respectively. Stimulation also produced significant (P ≤ 0.001) improvements in peak hip and knee flexion, ankle angle at foot off and at mid-swing. CONCLUSION: An implanted neuroprosthesis enabled a subject with incomplete SCI to walk longer distances with improved hip and knee flexion and ankle dorsiflexion resulting in decreased oxygen consumption and UE support. Further research is required to determine the robustness, generalizability and functional implications of implanted neuroprostheses for community ambulation after incomplete SCI.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Próteses e Implantes , Traumatismos da Medula Espinal/reabilitação , Caminhada/fisiologia , Feminino , Marcha , Articulação do Quadril , Humanos , Articulação do Joelho , Pessoa de Meia-Idade , Amplitude de Movimento Articular
6.
J Neuroeng Rehabil ; 14(1): 118, 2017 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-29149885

RESUMO

The reduction in physical activity following a spinal cord injury often leads to a decline in mental and physical health. Developing an exercise program that is effective and enjoyable is paramount for this population. Although functional electrical stimulation (FES) stationary cycling has been utilized in rehabilitation settings, implementing an overground cycling program for those with spinal cord injuries has greater technical challenges. Recently our laboratory team focused on training five individuals with compete spinal cord injuries utilizing an implanted pulse generator for an overground FES bike race in CYBATHLON 2016 held in Zurich, Switzerland. The advancements in muscle strength and endurance and ultimately cycling power our pilots made during this training period not only helped propel our competing pilot to win gold at the CYBATHLON 2016, but allowed our pilots to ride their bikes outside within their communities. Such a positive outcome has encouraged us to put effort into developing more widespread use of FES overground cycling as a rehabilitative tool for those with spinal cord injuries. This commentary will describe our approach to the CYBATHLON 2016 including technological advancements, bike design and the training program.


Assuntos
Ciclismo , Terapia por Estimulação Elétrica/métodos , Terapia por Exercício/métodos , Traumatismos da Medula Espinal/reabilitação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Am J Phys Med Rehabil ; 96(9): e170-e172, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28151761

RESUMO

A patient with multiple sclerosis-related gait dysfunction was followed over the course of his disease. Despite aggressive treatment, he developed significant weakness in ankle dorsiflexors and hip and knee flexors and was no longer capable of consistently taking a step on his own. With electrical stimulation of hip and knee flexors and ankle dorsiflexors using implanted electrodes, he was able to consistently walk short distances as far as 30 m, thus significantly improving his Expanded Disability Status Scale score. This case study supports further exploration into the potential benefits of an implanted pulse generator to ameliorate gait dysfunction and improve quality of life for people with multiple sclerosis.


Assuntos
Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados , Transtornos Neurológicos da Marcha/reabilitação , Esclerose Múltipla/reabilitação , Caminhada/fisiologia , Avaliação da Deficiência , Estudos de Viabilidade , Marcha/fisiologia , Transtornos Neurológicos da Marcha/etiologia , Transtornos Neurológicos da Marcha/fisiopatologia , Humanos , Extremidade Inferior/inervação , Extremidade Inferior/fisiopatologia , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Esclerose Múltipla/fisiopatologia , Recuperação de Função Fisiológica , Resultado do Tratamento
8.
J Rehabil Res Dev ; 51(5): 747-60, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25333890

RESUMO

Spinal cord injury (SCI) can compromise the ability to maintain an erect seated posture. This study examined the feasibility of a sensor-based threshold controller to automatically modulate stimulation to paralyzed hip and trunk extensor muscles to restore upright sitting from forward leaning postures. Forward trunk tilt was estimated from the anterior-posterior component of gravitational acceleration sensed by a sternum-mounted wireless accelerometer. Stimulation increased if trunk tilt exceeded a specified flexion threshold and ceased once upright sitting was resumed. The controller was verified experimentally in five volunteers with SCI and successfully returned all subjects to upright postures from forward leaning positions. Upper-limb effort exerted while returning to erect posture was significantly reduced (to 7.4% +/- 3.7% of body mass) pooled across all volunteers while using the controller compared with using continuous and no stimulation (p < 0.03). Controller response times were consistent among subjects when applied while sitting with (0.30 +/- 0.05 s) or without a backrest (0.34 +/- 0.11 s). The controller enabled volunteers to lean farther forward (59.7° +/- 16.4°) in wheelchairs without upper-limb effort than with no stimulation. Clinical utility of the system for facilitating reach or preventing falls remains to be determined in future studies.


Assuntos
Terapia por Estimulação Elétrica/métodos , Músculo Esquelético/fisiopatologia , Equilíbrio Postural/fisiologia , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/reabilitação , Tronco/fisiopatologia , Acelerometria , Adulto , Fenômenos Biomecânicos , Vértebras Cervicais , Terapia por Estimulação Elétrica/instrumentação , Estudos de Viabilidade , Retroalimentação , Feminino , Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Postura , Vértebras Torácicas , Extremidade Superior/fisiologia , Cadeiras de Rodas
9.
Arch Phys Med Rehabil ; 94(10): 1997-2005, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23628377

RESUMO

OBJECTIVE: To quantify the effects of stabilizing the paralyzed trunk and pelvis with electrical stimulation on manual wheelchair propulsion. DESIGN: Single-subject design case series with subjects acting as their own concurrent controls. SETTING: Hospital-based clinical biomechanics laboratory. PARTICIPANTS: Individuals (N=6; 4 men, 2 women; mean age ± SD, 46 ± 10.8y) who were long-time users (6.1 ± 3.9y) of implanted neuroprostheses for lower extremity function and had chronic (8.6 ± 2.8y) midcervical- or thoracic-level injuries (C6-T10). INTERVENTIONS: Continuous low-level stimulation to the hip (gluteus maximus, posterior adductor, or hamstrings) and trunk extensor (lumbar erector spinae and/or quadratus lumborum) muscles with implanted intramuscular electrodes. MAIN OUTCOME MEASURES: Pushrim kinetics (peak resultant force, fraction effective force), kinematics (cadence, stroke length, maximum forward lean), and peak shoulder moment at preferred speed over 10-m level surface; speed, pushrim kinetics, and subjective ratings of effort for level 100-m sprints and up a 30.5-m ramp of approximately 5% grade. RESULTS: Three of 5 subjects demonstrated reduced peak resultant pushrim forces (P≤.014) and improved efficiency (P≤.048) with stimulation during self-paced level propulsion. Peak sagittal shoulder moment remained unchanged in 3 subjects and increased in 2 others (P<.001). Maximal forward trunk lean also increased by 19% to 26% (P<.001) with stimulation in these 3 subjects. Stroke lengths were unchanged by stimulation in all subjects, and 2 showed extremely small (5%) but statistically significant increases in cadence (P≤.021). Performance measures for sprints and inclines were generally unchanged with stimulation; however, subjects consistently rated propulsion with stimulation to be easier for both surfaces. CONCLUSIONS: Stabilizing the pelvis and trunk with low levels of continuous electrical stimulation to the lumbar trunk and hip extensors can positively impact the mechanics of manual wheelchair propulsion and reduce both perceived and physical measures of effort.


Assuntos
Terapia por Estimulação Elétrica/métodos , Traumatismos da Medula Espinal/reabilitação , Cadeiras de Rodas , Adulto , Fenômenos Biomecânicos , Feminino , Quadril/fisiopatologia , Humanos , Região Lombossacral/fisiopatologia , Masculino , Pessoa de Meia-Idade , Ombro/fisiopatologia , Tronco/fisiopatologia
10.
Arch Phys Med Rehabil ; 94(9): 1766-75, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23500182

RESUMO

OBJECTIVE: To determine the stimulated strength of the paralyzed gluteal and paraspinal muscles and their effects on the seated function of individuals with paralysis. DESIGN: Case series with subjects acting as their own concurrent controls. SETTING: Hospital-based clinical biomechanics laboratory. PARTICIPANTS: Users (N=8) of implanted neuroprostheses for lower extremity function with low-cervical or thoracic level injuries. INTERVENTIONS: Dynamometry and digital motion capture both with and without stimulation to the hip and trunk muscles. MAIN OUTCOME MEASURES: Isometric trunk extension moment at 0°, 15°, and 30° of flexion; seated stability in terms of simulated isokinetic rowing; pelvic tilt, shoulder height, loaded and unloaded bimanual reaching to different heights, and subjective ratings of difficulty during unsupported sitting. RESULTS: Stimulation produced significant increases in mean trunk extension moment (9.2±9.5Nm, P<.001) and rowing force (27.4±23.1N, P<.012) over baseline volitional values. Similarly, stimulation induced positive changes in average pelvic tilt (16.7±15.7°) and shoulder height (2.2±2.5cm) during quiet sitting and bimanual reaching, and increased mean reach distance (5.5±6.6cm) over all subjects, target heights, and loading conditions. Subjects consistently rated tasks with stimulation easier than voluntary effort alone. CONCLUSIONS: In spite of considerable intersubject variability, stabilizing the paralyzed trunk with electrical stimulation can positively impact seated posture, extend forward reach, and allow exertion of larger forces on objects in the environment.


Assuntos
Terapia por Estimulação Elétrica/métodos , Quadril , Músculo Esquelético/fisiopatologia , Traumatismos da Medula Espinal/reabilitação , Tronco , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Dinamômetro de Força Muscular , Postura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA