Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
World J Urol ; 41(12): 3471-3483, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37980297

RESUMO

OBJECTIVE: To compare long-term reoperation rate and functional outcomes between EEP (endoscopic enucleation of the prostate) and TURP (transurethral resection of the prostate). EVIDENCE ACQUISITION: A systematic literature review of Medline, Scopus, and Web of Science was conducted with primary outcome assessed being reoperation rate and secondary outcomes after a long term (> 3 years) being functional outcomes or related values (prostate volume, PSA level, etc.). EVIDENCE SYNTHESIS: Five studies were found with long-term follow-up 4-7 years. EEP reoperation rate ranged from 0 to 1.27%, while from 1.7 to 17.6% for TURP. Meta-analysis showed significantly lower OR for EEP, 0.27 (95% CI 0.24-0.31), with notable homogeneity of the results, I2 = 0%. Long-term Qmax and IPSS were significantly better for EEP. Qmax pooled mean difference was 1.79 (95% CI 1.72-1.86) ml/s with a high concordance among the studies, I2 = 0%. IPSS mean difference -1.24 (95% CI - 1.28 to - 1.2) points, I2 = 57% but QoL did not differ, with mean difference being 0.01 (95% CI - 0.02 to 0.04), I2 = 0%. IIEF-5 score was also significantly better for EEP, mean difference 1.08 (95% CI 1.03-1.13), but heterogeneity was high, I2 = 70%. PSA level and prostate volume were only reported in one study and favored EEP slightly yet statistically significant. CONCLUSION: EEP had a significantly lower reoperation rate and better functional outcomes (Qmax and IPSS) at long term compared with TURP. It may also be beneficial in terms of IIEF-5, PVR, and PSA level.


Assuntos
Hiperplasia Prostática , Ressecção Transuretral da Próstata , Masculino , Humanos , Ressecção Transuretral da Próstata/métodos , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/complicações , Qualidade de Vida , Antígeno Prostático Específico , Resultado do Tratamento
2.
BMC Urol ; 23(1): 27, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36855070

RESUMO

BACKGROUND: Mesh erosion into the bladder after hernioplasty is sparsely reported in literature and may be underestimated in clinical practice. We report a case of a patient who was referred to our department due to recurrent urinary tract infections caused by a bladder stone due to mesh migration after inguinal hernia repair 22 years ago. CASE PRESENTATION: A 67-year-old male patient was referred from the outpatient urologist for transurethral resection of the prostate in September 2021 due to recurrent urinary tract infections caused by benign prostatic enlargement and bladder stone formation. During the operation, parts of the stone were smashed and the prostate was resected. Additionally, a mesh eroding from the bladder roof was detected masqueraded by the stone. A computed tomography scan, which was performed afterwards, revealed a 20 × 25 mm mesh migration into the bladder after inguinal hernia repair on the left with concomitant stone adhesion to the mesh. After revealing patient history, an inguinal hernia repair with mesh implantation was done 22 years ago. A robotic assisted partial cystectomy and mesh excision was performed. The patient recovered well. CONCLUSION: Mesh erosion into the urinary bladder after hernia repair can occur up to two decades after the primary operation. Although it is rarely reported, it can be a possible cause for recurrent urinary tract infections and therefore a mentionable complication after inguinal hernia operation. Robotic-assisted laparoscopic partial cystectomy with complete excision of the mesh is an option for definitive treatment.


Assuntos
Hérnia Inguinal , Procedimentos Cirúrgicos Robóticos , Ressecção Transuretral da Próstata , Cálculos da Bexiga Urinária , Masculino , Humanos , Idoso , Bexiga Urinária , Cistectomia/efeitos adversos , Hérnia Inguinal/cirurgia , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Telas Cirúrgicas/efeitos adversos
3.
World J Urol ; 40(12): 3015-3020, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36239811

RESUMO

PURPOSE: To determine the safety and efficacy of transurethral resection of the prostate (TUR-P) in patients 85 years or older. METHODS: In this retrospective, multicentre study, patients equal or older than 85 years at the time of surgery (2015-2020) were included. Several pre-, peri- and postoperative parameters were collected. The main outcome criterion was spontaneous voiding with a post-void residual (PVR) volume < 100 ml at dismission and at 12 months after surgery. RESULTS: One hundred sixty-eight patients (median age: 87 years, interquartile range [IQR]: 86-89) were recruited. The patients took on average 5.2 permanent medications (3-8), 107 (64%) were anticoagulated preoperatively and neurological co-morbidities were present in 29 (17%). The indication for surgery was recurrent urinary retention in 66.3% (n = 110) with a mean retention volume of 849 ml. The mean PVR volume of the remaining 35% was 146 ml. Surgery was successfully completed in all patients. A perioperative surgical revision had to be performed in 3% and 13 patients (7.7%) required blood transfusion. After catheter removal, 85% of patients were able to void spontaneously with a PVR < 100 ml, and 14.3% were dismissed with a catheter. Twelve months data were available for 93 patients (55%). Of this cohort, 78 (83.9%) were able to void spontaneously with a PVR < 100 ml, 12 (12.9%) were on permanent catheterization. One patient (0.6%) died perioperatively. The only significant factor associated with an unsuccessful outcome was the number of permanent medications (6.8 vs. 5.0, p = 0.005). CONCLUSION: This retrospective multicentre study documents the safety and efficacy of TURP (monopolar and bipolar) in the old-old cohort.


Assuntos
Hiperplasia Prostática , Ressecção Transuretral da Próstata , Masculino , Humanos , Idoso de 80 Anos ou mais , Hiperplasia Prostática/complicações , Hiperplasia Prostática/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Próstata/cirurgia
4.
J Endourol ; 36(9): 1231-1236, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35414204

RESUMO

Objective: The objective of our study was to estimate the long-term efficacy and safety of thulium fiber laser enucleation of the prostate (ThuFLEP). Materials and Methods: We analyzed patients who underwent ThuFLEP due to lower urinary tract symptoms (LUTS) related to benign prostatic obstruction (BPO). Both the pre- and perioperative data as well as the follow-up data for 3 years were evaluated: prostate volume, postvoid residual (PVR), maximum flow rate (Qmax), International Prostate Symptom Score (IPSS), quality of life (QoL), prostate-specific antigen level, and the complication rate. Intraoperative data relating to the weight of resected tissue, the duration of surgery, catheterization, and data on hospital stays were also collected. A subgroup analysis was performed to assess whether older patients (>65 years) or those with larger glands (>80 cc) are prone to increased complication risks. Results: A total of 1328 patients were included in the analysis. The mean age was 66.9 ± 7.5 years. Mean prostate volume was 86.9 ± 41.9 (20-330) cc. All the functional parameters (IPSS, QoL, PVR, Qmax) significantly improved after surgery (p < 0.05) and showed durable improvement up to 3 years of follow-up. The frequency of late complications was as follows: stress urinary incontinence-1.2%; urethral stricture-1.1%; and bladder neck contracture-0.9%. Subgroup analyses revealed increased urinary tract infection frequency in older patients (3.5% vs 0.8%, p = 0.003) as well as higher rate of stress urinary incontinence (0.4% vs 1.8%, p = 0.002) and higher rate of clot retention (11.3% vs 4.4%, p < 0.001) in those with larger glands. Conclusions: Irrespective of the patient's age and prostate volume, ThuFLEP represents an effective and durable technique of endoscopic enucleation characterized by a low incidence of complications after 3 years of follow-up. In the hands of an experienced surgeon, ThuFLEP can rightly be a promising alternative to holmium laser enucleation of the prostate for treatment of LUTS associated with BPO.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Incontinência Urinária por Estresse , Idoso , Humanos , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próstata/cirurgia , Hiperplasia Prostática/complicações , Hiperplasia Prostática/cirurgia , Qualidade de Vida , Túlio/uso terapêutico , Ressecção Transuretral da Próstata/métodos , Resultado do Tratamento , Incontinência Urinária por Estresse/cirurgia
5.
Eur Urol Focus ; 8(2): 532-544, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-33858810

RESUMO

CONTEXT: Although several studies have compared different morcellators and enucleation techniques for the management of benign prostatic hyperplasia (BPH), there is sparse literature on morcellation, so further experimental and clinical research is required for its optimization. OBJECTIVE: To critically appraise the contemporary literature on prostate morcellation and to evaluate the safety and efficiency of currently available morcellators for endoscopic enucleation of the prostate (EEP) in the context of BPH. EVIDENCE ACQUISITION: A comprehensive review of the English and French literature relevant to prostate morcellation was performed using the PubMed-MEDLINE, Cochrane Library, Web of Science, and Wiley Online Library database from 1998 to 2020 using PICOS (patient population, intervention, comparison, outcome, and study design) criteria. EVIDENCE SYNTHESIS: We retrieved 26 studies involving 5652 patients treated with a morcellator that were eligible for data extraction and analysis. The mean patient age was 67.4 (range 61.4-72.8) yr. The weighted mean efficiency of Piranha, VersaCut, and DrillCut morcellators was 5.29, 3.95, and 5.3 g/min, respectively. Several approaches, such as en bloc, two-lobe, inverse, and improved techniques, may increase morcellation efficiency and safety. The lowest weighted mean rate of bladder wall injury was 1.24% for Piranha, followed by 1.98% for DrillCut, and 5.23% for VersaCut, while the VersaCut morcellator had the lowest weighted mean rate of device malfunction at 0.74%, compared to 2.07% for Piranha and 7.86% for DrillCut. CONCLUSIONS: All three morcellators are efficient and safe for prostatic morcellation after EEP. Further development of devices and techniques may improve the efficiency and safety profile of morcellation. To increase safety, surgeon expertise, technical equipment, and patient characteristics should be considered. Therefore, interdisciplinary exchange of knowledge and further technological innovations are strongly encouraged. PATIENT SUMMARY: We reviewed the safety and efficacy of devices called morcellators. These devices cut tissue into small pieces that are easier to remove from the body, and are used during laser surgery for benign enlargement of the prostate. Three morcellators are currently available on the market and are comparable in safety and efficacy.


Assuntos
Lasers de Estado Sólido , Morcelação , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Humanos , Lasers de Estado Sólido/uso terapêutico , Masculino , Morcelação/efeitos adversos , Próstata/cirurgia , Hiperplasia Prostática/cirurgia
6.
Minerva Urol Nephrol ; 74(5): 559-569, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34791865

RESUMO

INTRODUCTION: Vaporization of the prostate (VP) and endoscopic enucleation of the prostate (EEP) are reliable and frequently used methods for BPO relief. Both surgeries utilize lasers and EAU recommends them in similar patient cohorts. Our objective was to compare intra- and perioperative results of patients who had undergone VP and EEP. EVIDENCE ACQUISITION: A systematic literature search was performed in three databases (MEDLINE, Web of Science and Scopus). The detailed search strategy is available at Prospero, CRD42020204739. Primary outcomes were functional results (IPSS, QoL, PVR, Qmax), and secondary outcomes were intraoperative results, postoperative PSA and prostate volume, complications, and recurrence rate. EVIDENCE SYNTHESIS: VP required less operative time compared to EEP, mean difference -5.51 (95% CI -7.52; -3.50). IPSS and Qmax for VP were worse after 12-month follow-up, mean difference 0.89 (95% CI 0.52; 1.27) and -3.7 (95% CI -4.56; -2.85), respectively, while QoL did not differ significantly. Postoperative PSA level was higher in the VP group, mean difference 2.28 (95% CI 2.00; 2.55). VP was associated with reduced Clavien-Dindo grade I (OR=4.16; 95% CI 2.96; 5.84) and grade II (OR=3.79; 95% CI 2.25; 6.39) complication rate, especially in terms of the percentage of blood transfusion and transient urinary incontinence. The rate of complications grade IIIa and higher was similar (3-6%). Reoperation rate was only estimated in one study and was significantly higher in the PVP group at 60 months of follow-up, 2.7% vs. 0%, P<0.05. CONCLUSIONS: EEP and VP share the efficacy and safety in BPH management. Our meta-analysis shows comparable complication rate in Clavien-Dindo III, VP superiority in operation time, and EEP superiority in long-term functional outcomes and PSA reduction.


Assuntos
Hiperplasia Prostática , Ressecção Transuretral da Próstata , Humanos , Masculino , Antígeno Prostático Específico , Hiperplasia Prostática/complicações , Hiperplasia Prostática/cirurgia , Qualidade de Vida , Ressecção Transuretral da Próstata/efeitos adversos , Ressecção Transuretral da Próstata/métodos , Resultado do Tratamento , Volatilização
7.
Curr Opin Urol ; 31(5): 444-450, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34265843

RESUMO

PURPOSE OF REVIEW: To summarize and comment on publications of the last 2 years in the field of endoscopic surgery for benign prostatic enlargement, focusing on similarities and differences of laser and electrosurgery. RECENT FINDINGS: Because of good hemostasis and safety, invasive endoscopic surgery has evolved to a choice of treatment for vulnerable patients with ongoing antithrombotic medication and in same-day surgery. Recent publications show a good perioperative course and no deterioration in the postoperative outcome. Furthermore, alterations to the original surgical techniques of resection, enucleation, and vaporization have increased the preservation rate for antegrade ejaculation, advancing them to an appealing choice of treatment for sexually active men. Favorable outcomes can be achieved in both laser and electrosurgery. Only the choice of the surgical technique determines the outcome. SUMMARY: Various invasive endoscopic surgical techniques are available, offering different advantages and disadvantages for the patient. All of them can be performed with laser and electrosurgery. Therefore, focusing on the proper choice of surgical technique instead of the energy source will guarantee the patient to benefit most.


Assuntos
Hiperplasia Prostática , Ressecção Transuretral da Próstata , Eletrocirurgia/efeitos adversos , Humanos , Lasers/efeitos adversos , Masculino , Hiperplasia Prostática/cirurgia , Resultado do Tratamento
8.
Urol J ; 18(5): 561-563, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33236335

RESUMO

PURPOSE: To detect possible effects of magnetic resonance imaging (MRI) scans on the function of an InterStim Twin sacral nerve stimulation (SNS) device and on patient's health. There is no authorization for MRI scans in InterStim Twin SNS at all. MATERIAL AND METHODS: 10 patients with Interstim Twin sacral nerve stimulator implants underwent a singular MRI scan. Before the MRI was performed, the SNS device function was evaluated and the device was deactivated be the implanting urologist. A continuous monitoring took place during MRI procedure. Micturition-time chart pre- and post MRI procedures were conducted. After the MRI session was completed, the implanted device was examined once more and reactivated, function then was evaluated. RESULTS: A total of 10 patients required MRI examinations in 8 different body regions. No patient reported pain or discomfort during and after the MRI scan. After reactivation of the InterStim Twin device following the MRI, impedances and stimulation amplitude, micturition frequency, urgency, and incontinence episodes remained stable. No significant differences between pre- and post MRI were found (p>0.05). CONCLUSION: This is the first report of patients successfully undergoing a MRI scan despite a previously implanted Interstim Twin sacral nerve stimulator. No negative effect of SNS function or negative side effects for the patients were observed.


Assuntos
Terapia por Estimulação Elétrica , Sintomas do Trato Urinário Inferior/terapia , Plexo Lombossacral , Imageamento por Ressonância Magnética , Transtornos Urinários/terapia , Idoso , Idoso de 80 Anos ou mais , Eletrodos Implantados , Feminino , Humanos , Plexo Lombossacral/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Retrospectivos
9.
Neurourol Urodyn ; 39(8): 2368-2372, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32886804

RESUMO

AIM: The aim of this study was to assess possible impacts of multiple magnetic resonance imaging (MRI) scans on the function of InterStim™ sacral neurostimulator systems (SNS; Medtronic Inc.) devices and on patient's safety. METHODS: Over the course of 17 years, a total of 16 patients required 72 MRI examinations in various parts of the body. Each time an MRI was performed, the implanting urologist evaluated the SNS device function and deactivated the implant before the scan. Patients were monitored continuously during and after the procedure. After the MRI session, the site of the implanted device was examined, and the SNS device was reactivated. RESULTS: None of the patients experienced pain or discomfort during or after the MRI scan. Impedances and stimulation amplitudes were recorded before and after MRI and showed no statistically significant changes regarding implant function. Micturition-time charts after MRI procedures were compared with previous records and showed no deviations either. No negative consequences of multiple MRIs have been observed. CONCLUSION: This is the first report of patients successfully undergoing multiple MRI scans despite a previously implanted SNS. Sixteen patients underwent more than one MRI scan, with no negative effect on the functional outcome of SNS or negative side effects for the patients.


Assuntos
Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sacro
10.
Urology ; 115: 151-156, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29526510

RESUMO

OBJECTIVE: To compare prostate volume and prostate-specific antigen (PSA) levels with bacterial growth in prostate tissue cultures. MATERIALS AND METHODS: Fifty male patients who underwent transurethral prostate resection were investigated prospectively. Resection chips from the prostate gland were added to brain-heart infusion medium and incubated. PSA levels were determined preoperatively at our urology ward. The prostate gland volume was estimated by transabdominal ultrasound examination preoperatively. RESULTS: Persons with positive bacterial prostate tissue cultures have a greater prostate volume. This is significant in patients with and without histopathologic signs of prostatitis. Persons with positive bacterial prostate tissue cultures have higher PSA values. This is significant in patients without histopathologic signs of prostatitis. CONCLUSION: People with positive bacterial prostatic tissue culture have a higher prostate volume in comparison with patients with negative culture findings and show a tendency toward increased PSA levels as well.


Assuntos
Antígeno Prostático Específico/sangue , Próstata/microbiologia , Próstata/patologia , Hiperplasia Prostática/patologia , Neoplasias da Próstata/patologia , Prostatite/patologia , Idoso , Idoso de 80 Anos ou mais , Bactérias/crescimento & desenvolvimento , Contagem de Colônia Microbiana , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Prospectivos , Próstata/cirurgia , Hiperplasia Prostática/sangue , Hiperplasia Prostática/microbiologia , Hiperplasia Prostática/cirurgia , Neoplasias da Próstata/sangue , Neoplasias da Próstata/microbiologia , Neoplasias da Próstata/cirurgia , Prostatite/sangue , Prostatite/complicações , Prostatite/microbiologia , Técnicas de Cultura de Tecidos , Ressecção Transuretral da Próstata
11.
Urology ; 109: 184-189, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28712889

RESUMO

OBJECTIVE: To investigate the efficacy and safety of the Adjustable Transobturator Male System (ATOMS) in men with stress urinary incontinence after transurethral resection of the prostate (TURP). MATERIALS AND METHODS: From a large international prospectively administrated ATOMS register, we identified 49 patients with an ATOMS device as a result of persistent stress urinary incontinence after TURP. For evaluation, the men were divided into standard transurethral resection of the prostate (sTURP) and palliative transurethral resection of the prostate (pTURP) in radiated patients. Baseline and follow-up measurements included continence parameters, urodynamics, quality-of-life surveys (Patient Global Impression-Improvement and International Consultation on Incontinence Questionnaire-Short Form), and pain ratings. The dry rate (0-1 security pad/<10 mL urine loss), the success rate (overall improvement), removals, complications, and treatment failures were recorded. A P value of <.05 was considered statistically significant. RESULTS: After a median of 34 and 22 months' follow-up and 2-3 adjustments, the sTURP and pTURP cohorts had 58% and 50% dry rates and 90% and 87% success rates. Hence, no improvement was seen in 10% and 13%. The removal rate was higher in pTURP (50% vs 10%, P = .0171) and infection was the most common side effect (50%) observed. Neither intraoperative nor Clavien-Dindo 4 and 5 adverse events were recorded. In sTURP and pTURP, the median daily pad count and the pad test improved significantly (all P <.001), and quality-of-life parameters shifted to a high satisfaction level (P <.001 and P = .001). Urodynamics remained unchanged and postoperative pain was not an issue. CONCLUSION: The ATOMS device shows promising treatment outcomes in patients after TURP and a similar efficacy as in postprostatectomy incontinence. There is no difference in continence outcome between sTURP and pTURP; however, a higher removal rate was found after pTURP, which may be important for patient counseling.


Assuntos
Complicações Pós-Operatórias/cirurgia , Slings Suburetrais , Ressecção Transuretral da Próstata , Incontinência Urinária por Estresse/cirurgia , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Humanos , Masculino , Estudos Retrospectivos , Slings Suburetrais/efeitos adversos , Resultado do Tratamento
12.
Minerva Urol Nefrol ; 68(3): 242-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26013949

RESUMO

BACKGROUND: The aim of this study was to evaluate the incidence of prostatic calcification and prostatitis NIH category IV in patients with obstructive BPH. METHODS: Ninety-six patients with obstructive BPH who had undergone transurethral electroresection of the prostate gland were evaluated. In accordance with a preoperative transrectal ultrasound examination, patients were divided into one group with prostatic calcification (N.=31) and one without (N.=65). Prostatitis NIH category IV was classified according to the grading system by Irani. Correlations between the incidence of prostatic calcification, histological prostatitis, PSA, uric acid, cholesterol, triglycerides, CRP, IPSS, IIEF-25, and NIC-CPSI were analyzed. A stone analysis of prostatic calcification was performed using X-ray powder diffraction. RESULTS: Sixty-nine (71.9%) patients had NIH category IV prostatitis, accounting for 83.9% of those with prostatic calcification versus 66.1% of those without (P<0.04). Significant correlations were found between prostatic calcification and the severity of inflammation (P<0.02) as well as the NIH-CPSI subdomain of urinary symptoms (P<0.02). The only predictor for prostatic calcifications were elevated levels of uric acid. Such patients were 1.4times more likely of having calcifications in the prostate gland (OR=1.4, P<0.047). Stone analysis revealed the following: apatite in 41.7%, whewellite in 29.2%, weddellite and brushite in 8.7% each, whitlockite, apatite/whewellite and organic substances in 4.2%. CONCLUSIONS: On ultrasound examination, one third of patients who were treated with TURP for obstructive BPH had prostatic calcification. These were significantly more common in patients with NIH category IV prostatitis.


Assuntos
Calcinose/patologia , Próstata/patologia , Hiperplasia Prostática/patologia , Prostatite/patologia , Idoso , Biomarcadores/urina , Calcinose/complicações , Calcinose/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/cirurgia , Hiperplasia Prostática/complicações , Hiperplasia Prostática/cirurgia , Prostatite/complicações , Prostatite/cirurgia , Ressecção Transuretral da Próstata , Cálculos Urinários/química , Transtornos Urinários/etiologia
13.
J Urol ; 186(5): 1967-71, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21944122

RESUMO

PURPOSE: We ascertained the safety and efficacy of the 1,318 nm diode Eraser laser (Rolle and Rolle, Salzburg, Austria) for transurethral enucleation of the prostate. This laser has been successfully used to resect lung metastasis. It cuts and coagulates vascular rich tissue safely and effectively. We describe a prospective, randomized trial of Eraser laser prostate enucleation vs bipolar transurethral prostate resection. MATERIALS AND METHODS: A total of 60 patients with lower urinary tract symptoms suggesting bladder outlet obstruction and a mean prostate size of 59.5 ml on transrectal ultrasound were randomized to Eraser laser prostate enucleation or bipolar transurethral prostate resection. Patients were assessed preoperatively, and 1 and 6 months postoperatively. RESULTS: Eraser laser prostate enucleation was equivalent to bipolar transurethral prostate resection in improvement in International Prostate Symptom Score, maximal flow rate and quality of life. Laser enucleation was significantly superior to bipolar transurethral resection for measured blood loss (mean ± SD 116.83 ± 97.02 vs 409.83 ± 148.61 ml), catheter time (mean 32.80 ± 8.74 vs 65.73 ± 13.72 hours) and hospital time (mean 45.13 ± 14.77 vs 91.20 ± 11.76 hours, each p <0.05). Using the validated Clavien-Dindo system there were 3 grade Id and 1 grade II complications. CONCLUSIONS: Eraser laser prostate enucleation and bipolar transurethral prostate resection were equally safe and effective to relieve bladder outflow obstruction and lower urinary tract symptoms. This laser technique has the advantage of less blood loss, and shorter catheter time and hospital stay.


Assuntos
Terapia a Laser/instrumentação , Lasers Semicondutores/uso terapêutico , Ressecção Transuretral da Próstata/instrumentação , Obstrução do Colo da Bexiga Urinária/cirurgia , Idoso , Perda Sanguínea Cirúrgica , Humanos , Terapia a Laser/métodos , Tempo de Internação , Sintomas do Trato Urinário Inferior/etiologia , Pessoa de Meia-Idade , Ressecção Transuretral da Próstata/métodos , Obstrução do Colo da Bexiga Urinária/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA