Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
PLoS One ; 13(6): e0193657, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29927924

RESUMO

BACKGROUND AND OBJECTIVES: Cytoreductive surgery (CRS) with hyperthermic intraperitoneal peroperative chemotherapy (HIPEC), indicated for patients with peritoneal metastases from digestive or gynecological malignancies alike, demonstrates a considerable impact on hemostatic metabolism, both on platelet and on coagulation level. The potential hemostatic interference in CRS and HIPEC is phase dependent. The hypothesis of this prospective cohort study is that the procedure exposed an increased thrombotic risk, resulting in a faster and increased thrombin generation and hyper platelet function. METHODS: This study explores the combined use of ROTEM (rotational thromboelastometry), PACT (platelet activation test) and CAT (thrombin generation test) assays during CRS and HIPEC with a follow-up of 7 days postoperative in 27 patients with confirmed histological diagnosis of peritoneal disease. RESULTS: Platelet reactivity (relative to before incision values) to CRP (collagen-related peptide) (p value 0.02) and TRAP (thrombin receptor activator peptide) (p value 0.048) seems to be slightly reduced during CRS and HIPEC with regard to αIIbß3 activation, while P-selectin expression is not affected. During surgery, CAT demonstrates that, the LT (lagtime) (p value 0.0003) and TTP (time-to-thrombin peak) values (p value 0.002) decrease while and the TP (thrombin peak) (p value 0.004) and ETP (endogenous thrombin potential) (p value 0.02) increase. Subsequently, after surgery, the LT and TTP increase and ETP and TP decrease in time. ROTEM EXTEM (extrinsic) MCF (maximum clot firmness) (p value 0.005), INTEM (intrinsic) MCF (p value 0.003) and FIBTEM (fibrinogen) MCF (p value <0.001) decreased during CRS. At day 7 INTEM and FIBTEM MCF values (p values of 0.004 and <0.001) were significantly higher than before surgery. No considerable changes in platelet count and hemoglobin concentration and absence of leukopenia are noticed. CONCLUSION: This approach detects changes in coagulation much earlier than noticed by standard coagulation tests.


Assuntos
Procedimentos Cirúrgicos de Citorredução , Hipertermia Induzida , Neoplasias Peritoneais/sangue , Neoplasias Peritoneais/terapia , Ativação Plaquetária , Trombina/metabolismo , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Neoplasias Peritoneais/patologia , Estudos Prospectivos , Tromboelastografia , Tempo de Trombina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA