1.
Rev Cardiovasc Med ; 18(1): 53-58, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28509894

RESUMO

Swallowing-induced supraventricular tachyarrhythmia is an extremely rare entity with unclear pathophysiology. A 55-year-old man presented with a 2-year history of worsening presyncopal symptoms triggered only by drinking liquids of any temperature. Results of a physical examination were unremarkable except for reproducible atrial tachycardias to 180 to 210 beats/minute documented on rhythm strips when the patient was given water to drink. He underwent radiofrequency ablation with complete resolution of symptoms. We reviewed all 43 published cases of swallowing-induced supraventricular tachyarrhythmia in the English-language medical literature. We found only one other reported case induced only by drinking liquids. Radiofrequency ablation appears to be the treatment of choice.


Assuntos
Deglutição , Ingestão de Líquidos , Taquicardia Supraventricular/etiologia , Potenciais de Ação , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
2.
Pacing Clin Electrophysiol ; 37(9): 1129-32, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24797921

RESUMO

BACKGROUND: During radiofrequency ablation (RFA), the ability to know whether a steam pop has led to cardiac perforation (CP) would be of profound clinical significance. We aimed to determine whether catheter contact-force characteristics can predict whether a steam pop during RFA causes CP. METHODS: We used a 7.5F Thermocool® Smarttouch™ force-sensing catheter (Biosense Webster Inc., Diamond Bar, CA, USA) to perform open-chest left atrial RFA under direct visualization in four sheep. We measured the contact force and its direction every 50 ms during RFA. At each steam pop, we noted whether CP occurred. We then analyzed the contact-force signals to determine whether specific features predicted the presence (+) or absence (-) of CP. RESULTS: A total of 24 steam pops occurred; 10 were CP+ and 14 were CP-. At the time of CP+ and CP- events, the contact force was 50 ± 25 and 40 ± 15 g, respectively (P = 0.146). All steam-pop events were associated with a rapid drop-off in contact force, but 10 of the 14 CP- events showed an immediate contact-force rebound, whereas none of the CP+ events did. This rebound presumably occurred as the catheter tip resumed contact with the left atrial wall. The average contact-force rebound equaled 80-100% of the contact-force drop-off. CONCLUSIONS: The ability to measure catheter contact force during RFA is a valuable asset, as contact-force recovery may be used to predict CP. Further studies are warranted to validate our findings in the clinical setting.


Assuntos
Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Traumatismos Cardíacos/etiologia , Temperatura Alta/efeitos adversos , Vapor/efeitos adversos , Animais , Técnicas Eletrofisiológicas Cardíacas , Modelos Animais , Valor Preditivo dos Testes , Ovinos , Estresse Mecânico
3.
Tex Heart Inst J ; 38(6): 621-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22199421

RESUMO

Studies have shown that long-term vagal stimulation is protective against ventricular fibrillation; however, the effects of acute vagal stimulation during ventricular fibrillation in the normal heart have not been investigated. We examined the effects of acute vagal stimulation on ventricular fibrillation in a canine model. In 4 dogs, we induced 30-second periods of ventricular fibrillation by means of intraventricular pacing. During 2 of the 4 periods of fibrillation that we analyzed, vagal stimulation was delivered through electrodes in the caudal ends of the vagus nerves. Noncontact unipolar electrograms were recorded from 3 ventricular regions: the basal septum, apical septum, and lateral free wall. We then computed the most frequent cycle length, mean organization index, and mean electrogram amplitude for each region. During fibrillation, vagal stimulation shortened the most frequent cycle lengths in the basal septum (P=0.02) and apical septum (P=0.0001), but not in the lateral wall (P=0.46). In addition, vagal stimulation significantly reduced the mean organization indices in the apical septum (P <0.001) and lateral wall (P <0.001), but not in the basal septum (P=0.19). Furthermore, vagal stimulation raised the mean electrogram amplitude in the basal septum (P <0.01) but lowered it substantially in the apical septum (P=0.00005) and lateral wall (P=0.00003). We conclude that vagal stimulation acutely affects the characteristics of ventricular fibrillation in canine myocardium in a spatially heterogeneous manner. This nonuniformity of response may have implications with regard to manipulating the autonomic system as a means of modifying the substrate for ventricular dysrhythmias.


Assuntos
Sistema de Condução Cardíaco/fisiopatologia , Estimulação do Nervo Vago , Fibrilação Ventricular/terapia , Função Ventricular Esquerda , Animais , Estimulação Cardíaca Artificial , Modelos Animais de Doenças , Cães , Técnicas Eletrofisiológicas Cardíacas , Análise de Fourier , Fatores de Tempo , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/fisiopatologia
4.
Pacing Clin Electrophysiol ; 33(2): 129-34, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19930106

RESUMO

INTRODUCTION: Assessment of ventricular activation pattern is critical to the successful ablation of ventricular tachycardia (VT). We have previously shown that the global atrial activation pattern during tachycardia can be rapidly and accurately assessed by calculating the postpacing interval variability (PPIV); PPIV was minimal in circuitous tachycardias and highly variable in centrifugal tachycardias. In the present study, we use the PPIV to determine the ventricular global activation pattern during VT. METHODS: Patients with mappable VT were included. We defined global ventricular activation as either centrifugal (arising from a focus with radial expansion) or circuitous (gross macro-reentrant circuit), based on the findings of electroanatomic mapping. PPIV was calculated as the difference in postpacing interval with right ventricular apical overdrive pacing during tachycardia at cycle lengths (CL) 10 ms and 30-ms shorter than tachycardia, regardless of the origin of the tachycardia. We studied 20 patients with 23 VTs (11 centrifugal, mean CL 390 +/- 36.1 ms; 12 circuitous, mean CL 418 +/- 75.7 ms). RESULTS: The mean PPIV was 45 +/- 16 ms for patients with centrifugal VT and 6.7 +/- 4.1 ms for patients with circuitous VT. Rank sum analysis of PPIV showed a significant difference between the two groups (P < 0.05). CONCLUSIONS: Our data suggest that the global ventricular activation pattern during VT can be rapidly and accurately defined by assessing the PPIV. This technique allows for a rapid confirmation of the tachycardia activation and significantly facilitates mapping and ablation.


Assuntos
Frequência Cardíaca/fisiologia , Taquicardia Ventricular/fisiopatologia , Adulto , Idoso , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Adulto Jovem
5.
Tex Heart Inst J ; 37(6): 695-8, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21224950

RESUMO

Permanent junctional reciprocating tachycardia, or atrioventricular reentrant tachycardia utilizing a slowly conducting posteroseptal accessory pathway, is a rare form of reentrant supraventricular tachycardia in children and adults. The characteristic features of this narrow complex tachycardia are a long RP interval and inverted P waves in the inferior leads. This form of accessory-pathway-mediated tachycardia, which is usually incessant, can lead to a tachycardia-induced cardiomyopathy and congestive heart failure if left untreated. Radiofrequency ablation of the accessory pathway in permanent junctional reciprocating tachycardia is the definitive treatment in these patients, and in many instances the effects of prolonged tachycardia on ventricular function are reversible after successful ablation. We present an illustrative case.


Assuntos
Cardiomiopatias/etiologia , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/complicações , Taquicardia Supraventricular/complicações , Adulto , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Cardiomiopatias/cirurgia , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Recuperação de Função Fisiológica , Volume Sistólico , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
6.
Heart Rhythm ; 6(5): 658-62, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19328040

RESUMO

BACKGROUND: We examined nonprescription weight-loss supplements marketed on the Internet for ingredients with potential arrhythmogenic and life-threatening cardiac adverse effects. OBJECTIVE: We aimed to define the risks of life-threatening cardiac adverse effects that are associated with weight-loss supplements marketed on the Internet. METHODS: We entered the key words "weight-loss supplements" and "diet pills" into three popular Internet search engines. The top four nonoverlapping hits from each search engine were purchased. After receipt, the products and their ingredient lists were inspected, and Medline and the Natural Medicines Comprehensive Database were searched for reports of significant associations between each ingredient and various key words for life-threatening cardiac adverse effects. RESULTS: All supplements had the list of ingredients on the label. We identified 60 different ingredients (7.25 +/- 4.66 per supplement; range 1-21). Eleven ingredients representing eight different substances (because multiple names were used for some substances) were each associated with two or more reports of life-threatening cardiac complications or death. Eight of the 12 products contained one or more such ingredients, but none of these eight products had warnings about life-threatening cardiac adverse effects on the Web pages, on the labels, or in the package inserts. One product contained ma huang (Chinese ephedra), even though the marketing of ephedra-containing products is banned in the United States. CONCLUSIONS: The Internet provides easy access to weight-loss supplements, several of which contain ingredients with potentially life-threatening adverse effects. There is a need for increased public education and awareness regarding such weight-loss products.


Assuntos
Fármacos Antiobesidade/efeitos adversos , Arritmias Cardíacas/induzido quimicamente , Suplementos Nutricionais/efeitos adversos , Internet/estatística & dados numéricos , Marketing/estatística & dados numéricos , Obesidade/prevenção & controle , Publicidade , Fármacos Antiobesidade/provisão & distribuição , Arritmias Cardíacas/epidemiologia , Suplementos Nutricionais/provisão & distribuição , Humanos , Incidência , Disseminação de Informação , Educação de Pacientes como Assunto , Estados Unidos/epidemiologia , Redução de Peso
7.
Circulation ; 113(25): 2871-9, 2006 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-16769912

RESUMO

BACKGROUND: Delivery of inappropriate shocks caused by misdetection of supraventricular tachycardia (SVT) remains a substantial complication of implanted cardioverter/defibrillator (ICD) therapy. Whether use of optimally programmed dual-chamber ICDs lowers this risk compared with that in single-chamber ICDs is not clear. METHODS AND RESULTS: Subjects with a clinical indication for ICD (n=400) at 27 participating centers received dual-chamber ICDs and were randomly assigned to strictly defined optimal single- or dual-chamber detection in a single-blind manner. Programming minimized ventricular pacing. The primary end point was the proportion of SVT episodes inappropriately detected from the time of programming until crossover or end of study. On a per-episode basis, 42% of the episodes in the single-chamber arm and 69% of the episodes in the dual-chamber arm were due to SVT. Mortality (3.5% in both groups) and early study withdrawal (14% single-chamber, 11% dual-chamber) were similar in both groups. The rate of inappropriate detection of SVT was 39.5% in the single-chamber detection arm compared with 30.9% in the dual-chamber arm. The odds of inappropriate detection were decreased by almost half with the use of the dual-chamber detection enhancements (odds ratio, 0.53; 95% confidence interval, 0.30 to 0.94; P=0.03). CONCLUSIONS: Dual-chamber ICDs, programmed to optimize detection enhancements and to minimize ventricular pacing, significantly decrease inappropriate detection.


Assuntos
Arritmias Cardíacas/diagnóstico , Desfibriladores Implantáveis/normas , Cardioversão Elétrica/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Frequência Cardíaca/fisiologia , Taquicardia Supraventricular/diagnóstico , Idoso , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Nó Atrioventricular/fisiologia , Estimulação Cardíaca Artificial/métodos , Intervalos de Confiança , Estudos Cross-Over , Desfibriladores Implantáveis/efeitos adversos , Diagnóstico Diferencial , Cardioversão Elétrica/métodos , Eletrocardiografia , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Método Simples-Cego , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Fatores de Tempo , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
8.
Pacing Clin Electrophysiol ; 26(1P2): 471-3, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12687870

RESUMO

INTRODUCTION: Previous studies using various bipolar pacemaker leads have shown that the AutoCapture (AC) Pacing System is able to verify ventricular capture and regulate pacing output, increasing patient safety with respect to unexpected threshold changes and potentially prolonging device longevity. An increasing number of patients with implantable cardioverter defibrillators (ICDs) require ventricular pacing that contributes to a shortening of longevity of these systems. This prospective study tested the compatibility of the AC system with bipolar ICD leads. METHODS: The AC algorithm was evaluated prior to ICD testing in 30 ICD recipients. A single coil, active fixation, true bipolar ventricular lead was implanted in 21 patients, and a dual coil, passive fixation, integrated bipolar ventricular lead was implanted in 9 patients. A ventricular evoked response sensitivity test and an AC threshold test were performed using a pacemaker with the ventricular AC algorithm. RESULTS: AC was recommended in 22/30 (73.3%) of implants, including 20/21 (95.2%) with the single coil and 2/9 (22.2%) with the dual coil lead. Mean polarization was lower (1.23 +/- 0.95 mV vs 3.70 +/- 2.33 mV, P = 0.013) while the mean evoked response was higher (18.04 +/- 8.29 mV vs 10.13 +/- 4.22 mV, P = 0.002) with the single coil leads. CONCLUSION: Automatic threshold tracking using the AC is compatible with ICD leads. Leads with lower polarization and greater evoked response are more likely to result in recommendation of AC use. Use of this system offers the potential for increasing ICD generator longevity and improving patient safety in response to late unexpected threshold increases.


Assuntos
Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Eletrocardiografia , Idoso , Algoritmos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos