Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 48(2): 257-262, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38271533

RESUMO

OBJECTIVE: Computed tomography pulmonary angiogram (CTPA) is important to evaluate suspected pulmonary embolism in pregnancy but has maternal/fetal radiation risks. The objective of this study was to estimate maternal and fetal radiation-induced cancer risk from CTPA during pregnancy. METHODS: Simulation modeling via the National Cancer Institute's Radiation Risk Assessment Tool was used to estimate excess cancer risks from 17 organ doses from CTPA during pregnancy, with doses determined by a radiation dose indexing monitoring system. Organ doses were obtained from a radiation dose indexing monitoring system. Maternal and fetal cancer risks per 100,000 were calculated for male and female fetuses and several maternal ages. RESULTS: The 534 CTPA examinations had top 3 maternal organ doses to the breast, lung, and stomach of 17.34, 15.53, and 9.43 mSv, respectively, with a mean uterine dose of 0.21 mSv. The total maternal excess risks of developing cancer per 100,000 were 181, 151, 121, 107, 94.5, 84, and 74.4, respectively, for a 20-, 25-, 30-, 35-, 40-, 45-, and 50-year-old woman undergoing CTPA, compared with baseline cancer risks of 41,408 for 20-year-old patients. The total fetal excess risks of developing cancer per 100,000 were 12.3 and 7.3 for female and male fetuses, respectively, when compared with baseline cancer risks of 41,227 and 48,291. DISCUSSION: Excess risk of developing cancer from CTPA was small relative to baseline cancer risk for pregnant patients and fetuses, decreased for pregnant patients with increasing maternal age, and was greater for female fetuses than male fetuses.


Assuntos
Neoplasias Induzidas por Radiação , Embolia Pulmonar , Adulto , Feminino , Humanos , Masculino , Gravidez , Adulto Jovem , Angiografia , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia por Tomografia Computadorizada/métodos , Atenção à Saúde , Feto , Pulmão , Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias Induzidas por Radiação/etiologia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/epidemiologia , Doses de Radiação , Estudos Retrospectivos , Pessoa de Meia-Idade
2.
Eur J Radiol ; 121: 108721, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31711025

RESUMO

PURPOSE: There is a large range of published effective radiation dose for CTPA during pregnancy. The purpose of our study is to determine the mean effective radiation dose and predictors of mean effective radiation dose for CTPA in pregnant patients across a multihospital integrated healthcare network. METHODS: This retrospective study evaluates pregnant women who had a CTPA as the first primary advanced imaging test for evaluation of PE in a multihospital integrated healthcare network from January 2012-April 2017. Patient and CT-related data were obtained from the electronic health record and Radimetrics server (Radimetrics Inc, Bayer). DLP was recorded and effective radiation dose in mSv was determined using a conversation factor of 0.014 mSv·mGy-¹·cm-¹. Patient size was determined by water equivalent diameter. Bivariate and multivariate analysis were performed for effective radiation dose based on patient and CT factors. RESULTS: In the 534 CTPA exams, the mean effective radiation dose was 3.96 mSv. Bivariate analysis showed significant differences in radiation dose by trimester, p = 0.042: first trimester 4.52 mSv, second trimester 3.73 mSv, and third trimester 3.95 mSv. Multivariable analysis demonstrated CTPA during first trimester, increasing mAs, kVp, scan length, patient size, and use of mAs modulation, as well as decreasing pitch, to be predictive of higher effective radiation dose. CONCLUSION: Mean effective radiation dose was on the lower end of published studies. Trimester was a statistically significant predictor of effective radiation dose when accounting for known predictors of radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Prestação Integrada de Cuidados de Saúde/métodos , Complicações na Gravidez/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Doses de Radiação , Adulto , Feminino , Humanos , Pulmão/diagnóstico por imagem , Gravidez , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA