Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Europace ; 21(3): 492-501, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30481301

RESUMO

AIMS: Substrate based catheter ablation strategies are widely employed for treatment of scar-related ventricular tachycardia (VT). We analysed intracardiac electrograms (EGMs) from close-coupled paced extrastimuli extracted from the EnSite Precision mapping system. We sought to characterize EGM responses of ventricular myocardium to varying coupling intervals from the right ventricular apex (RVA) in both healthy individuals and patients presenting with VT for catheter ablation. METHODS AND RESULTS: Extrastimuli were delivered from the RVA after estimation of the ventricular effective refractory period. Electrograms were recorded from high-density mapping catheters in the left ventricle and exported for analysis to MATLAB. Observational data were collected from 14 patients with ischaemic VT (mean age 72.4 ± 6.3 years, one female) and five controls (mean age 59.4 ± 7.4 years, one female). These derived data were used to inform an interventional strategy on a further 10 patients (mean age 64.7 ± 10.0 years; two female). Significant differences were observed in EGM duration (ED) and latency (LT) at all coupling intervals between VT patients and controls. Significant increases in ED and LT with decreased RVA coupling interval were observed at VT isthmuses. Abnormal responses derived from control subject data were used to classify four types of ventricular EGM response. Targeting sites with abnormal LT and ED significantly reduced VT inducibility (5/14 derivation patients to 0/10 intervention patients; P = 0.03). CONCLUSION: Paced electrogram feature analysis is a novel tool to characterize the ischaemic substrate. Association with VT isthmuses and early ablation results suggest a possible role in substrate ablation for ischaemic VT.


Assuntos
Potenciais de Ação , Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/diagnóstico , Função Ventricular Esquerda , Idoso , Estudos de Casos e Controles , Ablação por Cateter , Feminino , Ventrículos do Coração/cirurgia , Humanos , Masculino , Valor Preditivo dos Testes , Período Refratário Eletrofisiológico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fatores de Tempo
2.
Europace ; 15(3): 447-52, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23154844

RESUMO

AIMS: Catheter ablation for paroxysmal atrial fibrillation (AF) is rapidly becoming a standard practice. There is literature to support that catheter ablation of persistent AF requires additional 'substrate modification'. In clinical practice, operators rely on automated fractionation maps created by three-dimensional anatomic mapping systems to rapidly assess complex 'fractionated' signals (CFAE). These systems use differing algorithms to automate the process. The agreement between operators and contemporary algorithms has not been examined. We sought to assess the agreement between operators and a novel method of quantification calculating percentage fractionation (PF). METHODS AND RESULTS: Expert opinion on 80 atrial electrogram 4 s signals of varying levels of activity were gathered and pooled for comparison. Twelve independent experts visually quantified the signal fractionation and offered a threshold level for ablation. We developed an algorithm to find sites with high continuous electrical activity, or high PF. Correlation between experts and PF was 0.78 [P < 0.01, 95% confidence interval (CI) (0.68-0.86)]. Receiver operating characteristics curve sensitivity and specificity for PF were 0.7727 and 0.8103 at the optimal cut-off point of 58.45 PF with area under curve 0.89 CI (0.80-0.99). CONCLUSION: The PF statistic represents a more robust and intuitive measure to represent fractionated atrial activity; importantly it demonstrates excellent agreement with expert users and presents a new standard for algorithm assessment. Use of a PF statistic should be considered in automated mapping systems.


Assuntos
Algoritmos , Fibrilação Atrial/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Processamento de Sinais Assistido por Computador , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Automação , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
5.
J Cardiovasc Electrophysiol ; 23(4): 370-4, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22049976

RESUMO

UNLABELLED: Cardiac resynchronization therapy (CRT) benefits selected heart failure (HF) patients. The optimal placement of the right ventricle (RV) lead during biventricular pacing has not been assessed. Greater electrical separation (ES) between left ventricle (LV) and RV leads has been associated with better clinical outcomes. The site of maximal electrical separation(MES) in the RV is unknown. METHODS: Prospective study of 50 CRT patients. The LV lead was placed in a postero-lateral branch of the coronary sinus. ES was recorded at 6 sites within the RV during LV pacing at 600 milliseconds cycle length (CL). The median ES was recorded with a roving deflectable catheter at the RV outflow tract (RVOT), high septum, inflow septum, mid-septum, apical septum and apex. RESULTS: Mean age was 67 ± 7 years, 39 were male (78%). Thirty had ischemic etiology (60%). Mean left ventricular ejection fraction (LVEF) was 25 ± 7%, QRS duration pre and post was 165 ± 26 milliseconds and 138.5 ± 15.6 milliseconds (P < 0.001). Mapping ES showed a difference between 20 and 50 milliseconds distributed across the RV in the majority of patients (40/49). However, 7 subjects demonstrated delay distribution of between 50 and 82 milliseconds. ES was significant greater in the RV mid-septum (161.2 ± 23.7 milliseconds) compared with RVOT (154.1 ± 20.8 milliseconds) and apex (148.0 ± 25.5 milliseconds; P < 0.001). The site of Maximal ES was most commonly found at the mid-septum (40 patients, 80%) and only rarely at the RVOT (5, 10%) and apex (5, 10%; P < 0.01). CONCLUSION: MES was observed most commonly at the RV septum and rarely at the RV apex. Better correction of electrical and mechanical dyssynchrony by CRT may be achieved by placing the RV lead in a site outside of the apex in the majority of patients. Clinical studies exploring RV septal pacing in CRT seem warranted.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Potenciais de Ação , Idoso , Cateterismo Cardíaco , Terapia de Ressincronização Cardíaca/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Ontário , Estudos Prospectivos , Recuperação de Função Fisiológica , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Septo Interventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA