Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Lasers Med Sci ; 37(6): 2645-2653, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35257243

RESUMO

To investigate whether low-level laser therapy (LLLT), at different times of application (immediate and late) in the region of the parotid glands, has a distance effect on the microarchitecture of the trabecular bone in mandible of rats irradiated by volumetric modular arc therapy (VMAT). Thirty adult Wistar rats were randomly divided into placebo control groups (CG, n = 2), only radiotherapy (RG, n = 2), only LPLT (LG, n = 2), and two other groups using LLLT in the immediate time (24 h) (ILG, n = 12) and late (120 h) (LLG, n = 12) to radiotherapy by VMAT in a single dose of 12 Gy. LLLT with AsGaAl laser (660 nm, 100 mW), a spot size of 0.0028 cm2, was applied in three points in the region of the right parotid gland, with energy of 2 J/cm2, 20 s per point, for 10 consecutive days. After euthanasia, the right hemimandibles of each animal were dissected, prepared, and analyzed by computerized microtomography (micro-CT) and histomorphometry. The different groups were analyzed by the Tukey and Bonferroni multiple comparison tests. The micro-CT analysis found statistically significant differences between the groups, especially in the LLG, which had the highest average bone volume compared to the CG (p = 0.001) and ILG (p = 0.002) and a greater number of trabeculae than the CG (p = 0.000) and ILG (p = 0.031). The ILG also had a higher number of trabeculae than the CG (p = 0.005). Trabecula separation (Tb.Sp) was lower in the LLG (p = 0.000) and ILG (p = 0.002) when compared to the CG. In the histomorphometry, there was no statistical difference between the groups in relation to all the analyzed variables. Micro-CT analysis showed that the LLLT, even applied at a distance, both in the immediate and late VMAT times, has an effect on the mandibular bone microarchitecture by increasing the volume and number of trabeculae and decreasing the spaces between them.


Assuntos
Terapia com Luz de Baixa Intensidade , Animais , Osso Esponjoso , Terapia com Luz de Baixa Intensidade/métodos , Mandíbula/diagnóstico por imagem , Ratos , Ratos Wistar , Microtomografia por Raio-X
2.
Angle Orthod ; 86(2): 193-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26132512

RESUMO

OBJECTIVE: To evaluate the effect of using low-level laser therapy (LLLT) to control pain and discomfort during orthodontic treatment. MATERIALS AND METHODS: A randomized, split-mouth clinical trial was conducted with 30 volunteers in need of orthodontic treatment, of both genders, aged between 18 and 40 years, who were randomly divided into two groups. One hemiarch was considered the exposed group (EG) and the other, the placebo group (PG). Both groups had elastic separators placed mesially and distally to the first molars of the two hemiarches at different times. The EG received an AIGaAs diode LLLT (810 nm, 100 mW, 2J/cm(2)) application for 15 seconds per point (interdental papilla at the mesial, distal, and near the root apex) immediately after separator placement on the maxillary right side. The PG also had elastics placed around the maxillary right molars, but received only simulated LLLT application. The elastics were left in place for 5 days, and after a waiting period of 1 week, they were inserted on the left side in both groups; however, the order of laser application was changed. While the separator remained in place, the patient marked his degree of perceived discomfort on a Visual Analog Scale (VAS) at 5 minutes (T0), 24 hours (T1), and 120 hours (T2), after LLLT application. RESULTS: A statistically significant difference was observed (P < .005) in reducing discomfort in the exposed group compared with the placebo group. This reduction of discomfort in the EG was observed at all time intervals. CONCLUSIONS: A sincle AIGaAs diode LLLT application may be indicated for the control or reduction of pain in the early stages of orthodontic treatment.


Assuntos
Terapia com Luz de Baixa Intensidade , Ortodontia Corretiva , Manejo da Dor , Técnicas de Movimentação Dentária , Adolescente , Adulto , Feminino , Humanos , Masculino , Boca , Medição da Dor , Adulto Jovem
3.
J Oral Implantol ; 39(5): 533-8, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21534821

RESUMO

The present study measured removal torque and bone-implant interface resistance of machined implants, acid-etched implants, or machined implants irradiated around the implant area with infrared low-level laser therapy (LLLT; 830 nm) immediately after surgery. There were statistically significant differences between Groups A (control) and B (rough surface) (P = .03). Implants with a rough surface seem to add resistance to the bone-implant interface compared with smooth titanium implants or implants treated with LLLT.


Assuntos
Implantes Dentários , Remoção de Dispositivo , Osseointegração/efeitos da radiação , Análise de Variância , Animais , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Fêmur , Terapia com Luz de Baixa Intensidade , Ratos , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos da radiação , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA