Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Analyst ; 145(21): 6910-6918, 2020 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-32840500

RESUMO

Mass spectrometry imaging (MSI) is a powerful analytical technique that enables detection, discovery, and identification of multiple classes of biomolecules, while simultaneously mapping their spatial distributions within a sample (e.g., a section of biological tissue). The limitation in molecular coverage afforded by any single MSI platform has led to the development of multimodal approaches that incorporate two or more techniques to obtain greater chemical information. Matrix-assisted laser desorption ionization (MALDI) is a preeminent ionization technique for MSI applications because the wide range of available matrices allows some degree of enhancement with respect to the detection of particular molecular classes. Nonetheless, MALDI has a limited ability to detect and image several classes of molecules, e.g., neutral lipids, in complex samples. Laser desorption ionization from silicon nanopost arrays (NAPA-LDI or NAPA) has been shown to offer complementary coverage with respect to MALDI by providing improved detection of neutral lipids and some small metabolites. Here, we present a multimodal imaging method in which a single tissue section is consecutively imaged at low and high laser fluences, generating spectra that are characteristic of MALDI and NAPA ionization, respectively. The method is demonstrated to map the distributions of species amenable to detection by MALDI (e.g., phospholipids and intermediate-mass metabolites) and NAPA (e.g., neutral lipids such as triglycerides and hexosylceramides, and small metabolites) in mouse brain and lung tissue sections.


Assuntos
Imagem Molecular , Silício , Animais , Lasers , Camundongos , Imagem Multimodal , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
2.
J Mass Spectrom ; 55(4): e4443, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31524963

RESUMO

Mass spectrometry imaging (MSI) is used increasingly to simultaneously detect a broad range of biomolecules while mapping their spatial distributions within biological tissue sections. Matrix-assisted laser desorption ionization (MALDI) is recognized as the method-of-choice for MSI applications due in part to its broad molecular coverage. In spite of the remarkable advantages offered by MALDI, imaging of neutral lipids, such as triglycerides (TGs), from tissue has remained a significant challenge due to ion suppression of TGs by phospholipids, e.g. phosphatidylcholines (PCs). To help overcome this limitation, silicon nanopost array (NAPA) substrates were introduced to selectively ionize TGs from biological tissue sections. This matrix-free laser desorption ionization (LDI) platform was previously shown to provide enhanced ionization of certain lipid classes, such as hexosylceramides (HexCers) and phosphatidylethanolamines (PEs) from mouse brain tissue. In this work, we present NAPA as an MSI platform offering enhanced ionization efficiency for TGs from biological tissues relative to MALDI, allowing it to serve as a complement to MALDI-MSI. Analysis of a standard lipid mixture containing PC(18:1/18:1) and TG(16:0/16:0/16:0) by LDI from NAPA provided an ~49 and ~227-fold higher signal for TG(16:0/16:0/16:0) relative to MALDI, when analyzed without and with the addition of a sodium acetate, respectively. In contrast, MALDI provided an ~757 and ~295-fold higher signal for PC(18:1/18:1) compared with NAPA, without and with additional Na+ . Averaged signal intensities for TGs from MSI of mouse lung and human skin tissues exhibited an ~105 and ~49-fold increase, respectively, with LDI from NAPA compared with MALDI. With respect to PCs, MALDI provided an ~2 and ~19-fold increase in signal intensity for mouse lung and human skin tissues, respectively, when compared with NAPA. The complementary coverage obtained by the two platforms demonstrates the utility of using both techniques to maximize the information obtained from lipid MS or MSI experiments.


Assuntos
Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Triglicerídeos/análise , Animais , Humanos , Pulmão/citologia , Pulmão/metabolismo , Camundongos , Imagem Molecular , Nanoestruturas/química , Fosfatidilcolinas/análise , Silício/química , Pele/citologia , Pele/metabolismo , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação
3.
Anal Chem ; 91(6): 3951-3958, 2019 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-30786207

RESUMO

Silicon nanopost array (NAPA) structures have been shown to be effective substrates for laser desorption/ionization-mass spectrometry (LDI-MS) and have been used to analyze a variety of samples including peptides, metabolites, drugs, explosives, and intact cells, as well as to image lipids and metabolites in tissue sections. However, no direct comparison has yet been conducted between NAPA-MS and the most commonly used LDI-MS technique, matrix-assisted laser desorption/ionization (MALDI)-MS. In this work, we compare the utility of NAPA-MS to that of MALDI-MS using two common matrices for the analysis of metabolites in cellular extracts and human urine. Considerable complementarity of molecular coverage was observed between the two techniques. Of 178 total metabolites assigned from cellular extracts, 68 were uniquely detected by NAPA-MS and 62 were uniquely detected by MALDI-MS. NAPA-MS was found to provide enhanced coverage of low-molecular weight compounds such as amino acids, whereas MALDI afforded better detection of larger, labile compounds including nucleotides. In the case of urine, a sample largely devoid of higher-mass labile compounds, 88 compounds were uniquely detected by NAPA-MS and 13 by MALDI-MS. NAPA-MS also favored more extensive alkali metal cation adduction relative to MALDI-MS, with the [M + 2Na/K - H]+ species accounting for as much as 97% of the total metabolite ion signal in positive mode. The capability of NAPA-MS for targeted quantitation of endogenous metabolites in urine via addition of isotopically labeled standards was also examined. Both NAPA-MS and MALDI-MS provided quantitative results in good agreement with one another and the concentrations reported in the literature, as well as good sample-to-sample reproducibility (RSD < 10%).


Assuntos
Carcinoma Hepatocelular/metabolismo , Neoplasias Hepáticas/metabolismo , Metaboloma , Metabolômica/métodos , Nanoestruturas/química , Silício/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Células Hep G2 , Ensaios de Triagem em Larga Escala , Humanos , Marcação por Isótopo , Lasers , Reprodutibilidade dos Testes
4.
J Comp Neurol ; 527(13): 2101-2121, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30358893

RESUMO

Mass spectrometry imaging (MSI) is capable of detection and identification of diverse classes of compounds in brain tissue sections, whereas simultaneously mapping their spatial distributions. Given the vast array of chemical components present in neurological systems, as well as the innate diversity within molecular classes, MSI platforms capable of detecting a wide array of species are useful for achieving a more comprehensive understanding of their biological roles and significance. Currently, matrix-assisted laser desorption ionization (MALDI) is the method of choice for the molecular imaging of brain samples by mass spectrometry. However, nanostructured laser desorption ionization platforms, such as silicon nanopost arrays (NAPA), are emerging as alternative MSI techniques that can provide complementary insight into molecular distributions in the central nervous system. In this work, the molecular coverage of mouse brain lipids afforded by NAPA-MSI is compared to that of MALDI-MSI using two common MALDI matrices. In positive ion mode, MALDI spectra were dominated by phosphatidylcholines and phosphatidic acids. NAPA favored the ionization of phosphatidylethanolamines and glycosylated ceramides, which were poorly detected in MALDI-MSI. In negative ion mode, MALDI favored sulfatides and free fatty acids, whereas NAPA spectra were dominated by signal from phosphatidylethanolamines. The complementarity in lipid coverages between the NAPA- and MALDI-MSI platforms presents the possibility of selective lipid analysis and imaging dependent upon which platform is used. Nanofabrication of the NAPA platform offers better uniformity compared to MALDI, and the wider dynamic range offered by NAPA promises improved quantitation in imaging.


Assuntos
Encéfalo , Nanotecnologia/métodos , Neuroimagem/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Processamento de Imagem Assistida por Computador , Lipídeos/análise , Camundongos , Silício
5.
J Manipulative Physiol Ther ; 29(8): 672-5, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17045101

RESUMO

OBJECTIVE: The aim of the study was to discuss a case of cervical epidural abscess and present the clinical features and diagnosis of this disorder. CLINICAL FEATURES: A 52-year-old man had severe neck pain for 1 week. He had a long history of chronic recurrent neck pain, including 2 previous neck surgeries. He was afebrile on each visit, but developed rapid onset of motor loss, which necessitated immediate magnetic resonance imaging referral. The patient died in the magnetic resonance imaging tube. INTERVENTION AND OUTCOME: Because of the aggressive nature of the infection, causing death only 1 week after the initial onset of symptoms, there was no opportunity to institute treatment of the abscess. CONCLUSION: Spinal epidural abscess is a relatively rare but potentially life-threatening disorder in which the most common initial symptom is spinal pain. Because of this, patients with early spinal epidural abscess will often consult a chiropractic physician or other primary contact spine specialist. It is important for clinicians to be alert to the diagnostic features of spinal epidural abscess so that early treatment can be instituted.


Assuntos
Temperatura Corporal , Abscesso Epidural/complicações , Abscesso Epidural/diagnóstico , Imageamento por Ressonância Magnética , Cervicalgia/etiologia , Pescoço , Evolução Fatal , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos dos Movimentos/etiologia , Cervicalgia/fisiopatologia , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA