Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Cardiovasc Electrophysiol ; 28(1): 94-102, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27696593

RESUMO

INTRODUCTION: Approximately 10-20% of ICD recipients receive inappropriate device therapies. The purpose of this study was to compare the frequency of inappropriate therapies (IT) between men and women enrolled in MADIT II and MADIT-CRT, and assess for potential adverse outcomes. METHODS: The electrograms for each ICD or CRT-D therapy, defined as either ATP or shock, were reviewed by adjudication committees for both studies. ICD therapy was considered inappropriate if it was delivered for reasons other than VT/VF. The rhythm triggering IT was categorized as atrial fibrillation/flutter, SVT, or inappropriate sensing when possible. RESULTS: One thousand nine hundred and fifty-four men and 556 women received ICD or CRT-D devices. The risk of IT was significantly lower in women than men (9.2% vs. 13.5%, P = 0.006). The most common cause of IT in men was atrial fibrillation (38%) and SVT in women (43%). Inappropriate shock was not associated with increased mortality in either women (HR 0.82 [95% CI 0.11-6.08]; P = NS) or men (HR 1.37 [95% CI 0.75-2.48]; P = NS) by multivariate analysis. Conversely, appropriate shock therapy strongly correlated with increased risk of death during subsequent post-shock follow-up in women (HR 5.99 [95% CI 2.75-13.02]; P < 0.0001) and men (HR 2.61 [95% CI 1.82-3.74]; P < 0.0001). CONCLUSIONS: Women experience significantly less IT than men, partially explained by the increased frequency of atrial fibrillation in men. IT was not associated with increased mortality in either sex. Appropriate shock therapy was a strong predictor of death in both, with women showing a 2-fold higher risk than men during post-shock long-term follow-up.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Falha de Prótese , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores Sexuais , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia
2.
J Cardiovasc Electrophysiol ; 26(4): 424-433, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25546486

RESUMO

INTRODUCTION: The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. METHODS AND RESULTS: First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P < 0.001 for all comparisons). Occurrence of total inappropriate and appropriate ICD therapies was significantly reduced by high-rate cut-off ICD programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. CONCLUSION: High-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy.


Assuntos
Cardiomiopatias/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Falha de Equipamento , Isquemia Miocárdica/complicações , Taquicardia Ventricular/terapia , Idoso , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Distribuição de Qui-Quadrado , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Europa (Continente) , Feminino , Humanos , Israel , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Fatores de Risco , Processamento de Sinais Assistido por Computador , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
3.
Curr Cardiol Rep ; 16(6): 496, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24818705

RESUMO

Despite the clinical benefit of implantable cardioverter defibrillator (ICD), there is a high frequency of inappropriate ICD therapy associated with impaired quality of life, unwanted health care resource utilization, and adverse clinical outcome. Alternative strategies of ICD programming are needed to reduce the risk of inappropriate and "unnecessary" ICD therapies and to improve patient outcome. In this review, we provide an overview of the rate of inappropriate and appropriate ICD therapies in clinical trials and large registries as well as a review of current trials evaluating novel ICD programming to reduce inappropriate ICD therapy to avoid unnecessary ICD therapy. Based on recent studies including a large randomized trial, we recommend a simple programming approach involving high-rate device therapy beginning at 200 bpm with a 2.5 sec delay for it reduces inappropriate therapy, unnecessary therapy, and all-cause mortality in patients receiving ICD or CRT-D devices for primary prevention indications.


Assuntos
Fibrilação Atrial/terapia , Desfibriladores Implantáveis , Taquicardia Supraventricular/terapia , Taquicardia Ventricular/terapia , Procedimentos Desnecessários , Desfibriladores Implantáveis/estatística & dados numéricos , Feminino , Humanos , Masculino , Guias de Prática Clínica como Assunto , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento , Procedimentos Desnecessários/estatística & dados numéricos
4.
J Cardiovasc Electrophysiol ; 24(11): 1246-52, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23889863

RESUMO

BACKGROUND: Current data on efficacy, safety and impact on clinical outcome of single- versus dual-coil implantable cardioverter-defibrillator (ICD) leads are limited and contradictory. METHODS: Defibrillation threshold (DFT) at implantation and first shock efficacy were compared in patients implanted with single- versus dual-coil ICD leads in MADIT-CRT. The risk for atrial tachyarrhythmias and all-cause mortality were evaluated. Short- (< 30 days after the implantation) and long-term (throughout the entire study duration) complications were assessed. RESULTS: Patients with dual-coil ICD leads had significantly lower DFTs compared to patients with single-coil ICD leads (17.6 ± 5.8 J vs 19.4 ± 6.1 J, P < 0.001). First shock efficacy was similar among patients with dual and single-coil ICD leads (89.6% vs 92.3%, P = 1.00). When comparing patients with dual versus single-coil ICD leads, there was no difference in the risk of atrial tachyarrhythmias (HR = 1.57, 95% CI: 0.81-3.02, P = 0.18), or in the risk of all-cause mortality (HR = 1.10, 95% CI: 0.58-2.07, P = 0.77). Patients implanted with single- or dual-coil ICD lead had similar short and long-term complication rates (short-term HR = 0.96, 95% CI: 0.56-1.65, P = 0.88, long-term procedure-related HR = 0.99, 95% CI: 0.62-1.59, P = 1.00, long-term ICD lead related: HR = 1.2, 95% CI: 0.5-2.9, P = 0.68) during the mean follow-up of 3.3 years. CONCLUSIONS: Patients with single-coil ICD leads have slightly higher DFTs compared to those with dual-coil leads, but the efficacy, safety, and clinical impact on atrial tachyarrhythmias, and mortality is similar. Implantation of single-coil ICD leads may be favorable in most patients.


Assuntos
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
J Am Coll Cardiol ; 60(21): 2182-91, 2012 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-23153844

RESUMO

OBJECTIVES: The study was designed to assess the ability of computer-simulated electrocardiography parameters to predict clinical outcomes and to risk-stratify patients with long QT syndrome type 1 (LQT1). BACKGROUND: Although attempts have been made to correlate mutation-specific ion channel dysfunction with patient phenotype in long QT syndrome, these have been largely unsuccessful. Systems-level computational models can be used to predict consequences of complex changes in channel function to the overall heart rhythm. METHODS: A total of 633 LQT1-genotyped subjects with 34 mutations from multinational long QT syndrome registries were studied. Cellular electrophysiology function was determined for the mutations and introduced in a 1-dimensional transmural electrocardiography computer model. The mutation effect on transmural repolarization was determined for each mutation and related to the risk for cardiac events (syncope, aborted cardiac arrest, and sudden cardiac death) among patients. RESULTS: Multivariate analysis showed that mutation-specific transmural repolarization prolongation (TRP) was associated with an increased risk for cardiac events (35% per 10-ms increment [p < 0.0001]; ≥upper quartile hazard ratio: 2.80 [p < 0.0001]) and life-threatening events (aborted cardiac arrest/sudden cardiac death: 27% per 10-ms increment [p = 0.03]; ≥upper quartile hazard ratio: 2.24 [p = 0.002]) independently of patients' individual QT interval corrected for heart rate (QTc). Subgroup analysis showed that among patients with mild to moderate QTc duration (<500 ms), the risk associated with TRP was maintained (36% per 10 ms [p < 0.0001]), whereas the patient's individual QTc was not associated with a significant risk increase after adjustment for TRP. CONCLUSIONS: These findings suggest that simulated repolarization can be used to predict clinical outcomes and to improve risk stratification in patients with LQT1, with a more pronounced effect among patients with a lower-range QTc, in whom a patient's individual QTc may provide less incremental prognostic information.


Assuntos
Simulação por Computador , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca/genética , Modelos Cardiovasculares , Medição de Risco , Síndrome de Romano-Ward/fisiopatologia , Adolescente , Adulto , DNA/análise , Feminino , Seguimentos , Genótipo , Humanos , Canal de Potássio KCNQ1/genética , Masculino , Mutação , Fenótipo , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Fatores de Risco , Síndrome de Romano-Ward/genética , Síndrome de Romano-Ward/patologia , Adulto Jovem
6.
Eur Heart J ; 27(17): 2099-140, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16923744
8.
J Am Coll Cardiol ; 47(1): 98-107, 2006 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-16386671

RESUMO

UNLABELLED: In the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II, implantable cardioverter-defibrillator (ICD)-randomized patients underwent electrophysiologic testing. Both inducible and noninducible patients received an ICD. We correlated inducibility with the occurrence of subsequent ventricular tachycardia (VT) or ventricular fibrillation (VF). Intracardiac ICD electrograms for subsequent events were analyzed to categorize the spontaneous arrhythmia as VT or VF. The two-year Kaplan-Meier event rate for VT in inducible patients was 29.0% versus 19.3% in noninducible patients. However, ICD therapy for spontaneous VF was less common at two years in inducible patients (3.2%) than in noninducible patients (8.6%). In the MADIT II study, inducibility predicted an increased likelihood of VT but decreased VF. OBJECTIVES: We correlated electrophysiologic inducibility with spontaneous ventricular tachycardia (VT) or ventricular fibrillation (VF) in the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II. BACKGROUND: In the MADIT II study, 593 (82%) of 720 implantable cardioverter-defibrillator (ICD) randomized patients underwent electrophysiologic testing. Patients received an ICD whether they were inducible or not. METHODS: A "standard" inducibility definition included sustained monomorphic or polymorphic VT induced with three or fewer extrastimuli or VF induced with two or fewer extrastimuli. We compared a narrow inducibility definition (only monomorphic VT) and a broad definition (standard definition plus VF with three extrastimuli). We used ICD-stored electrograms to categorize spontaneous VT or VF. RESULTS: Inducible patients (standard definition) had a greater likelihood of experiencing ICD therapy for VT than noninducible patients (p = 0.023). Unexpectedly, ICD therapy for spontaneous VF was less common (p = 0.021) in inducible patients than in noninducible patients. The two-year Kaplan-Meier event rate for VT or VF was 29.4% for inducible patients and 25.5% for noninducible patients. Standard inducibility did not predict the combined end point of VT or VF (p = 0.280, by log-rank analysis). The narrow inducibility definition outperformed the standard definition, whereas the broad definition appeared inferior to the standard definition. CONCLUSIONS: In the MADIT II study patients, inducibility was associated with an increased likelihood of VT. Noninducible MADIT II study subjects using this electrophysiologic protocol had a considerable VT event rate and a higher VF event rate than inducible patients. Induction of polymorphic VT or VF, even with double extrastimuli, appears less relevant than induction of monomorphic VT.


Assuntos
Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/diagnóstico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA