Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Toxicol Appl Pharmacol ; 391: 114914, 2020 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-32032643

RESUMO

Polybrominated diphenyl ethers (PBDEs) are persistent environmental pollutants considered as neurotoxicants and endocrine disruptors with important biological effects ranging from alterations in growth, reproduction, and effects on the hypothalamus-pituitary-adrenal axis. The vasopressinergic (AVPergic) system is a known target for pentaBDEs mixture (DE-71) and the structurally similar chemicals, polychlorinated biphenyls. However, the potential adverse effects of mixtures containing octaBDE compounds, like DE-79, on the AVPergic system are still unknown. The present study aims to examine the effects of perinatal DE-79 exposure on the AVPergic system. Dams were dosed from gestational day 6 to postnatal day 21 at doses of 0 (control), 1.7 (low) or 10.2 (high) mg/kg/day, and male offspring from all doses at 3-months-old were subjected to normosmotic and hyperosmotic challenge. Male offspring where later assessed for alterations in osmoregulation (i.e. serum osmolality and systemic vasopressin release), and both vasopressin immunoreactivity (AVP-IR) and gene expression in the hypothalamic paraventricular and supraoptic nuclei. Additionally, to elucidate a possible mechanism for the effects of DE-79 on the AVPergic system, both neuronal nitric oxide synthase immunoreactivity (nNOS-IR) and mRNA expression were investigated in the same hypothalamic nuclei. The results showed that perinatal DE-79 exposure AVP-IR, mRNA expression and systemic release in adulthood under normosmotic conditions and more evidently under hyperosmotic stimulation. nNOS-IR and mRNA expression were also affected in the same nuclei. Since NO is an AVP regulator, we propose that disturbances in NO could be a mechanism underlying the AVPergic system disruption following perinatal DE-79 exposure leading to osmoregulation deficits.


Assuntos
Poluentes Ambientais/toxicidade , Éteres Difenil Halogenados/toxicidade , Vasopressinas/efeitos dos fármacos , Animais , Animais Recém-Nascidos , Feminino , Hipotálamo/metabolismo , Hipotálamo Anterior/metabolismo , Masculino , Óxido Nítrico/metabolismo , Óxido Nítrico Sintase Tipo I , Osmorregulação/efeitos dos fármacos , Pressão Osmótica/efeitos dos fármacos , Núcleo Hipotalâmico Paraventricular/metabolismo , Gravidez , Ratos , Ratos Wistar
2.
J Healthc Eng ; 2017: 4302810, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29065603

RESUMO

Epilepsy is a neurological disorder that affects approximately one percent of the world population. Noninvasive electrical brain stimulation via tripolar concentric ring electrodes has been proposed as an alternative/complementary therapy for seizure control. Previous results suggest its efficacy attenuating acute seizures in penicillin, pilocarpine-induced status epilepticus, and pentylenetetrazole-induced rat seizure models and its safety for the rat scalp, cortical integrity, and memory formation. In this study, neuronal counting was used to assess possible tissue damage in rats (n = 36) due to the single dose or five doses (given every 24 hours) of stimulation on hippocampal CA3 subregion neurons 24 hours, one week, and one month after the last stimulation dose. Full factorial analysis of variance showed no statistically significant difference in the number of neurons between control and stimulation-treated animals (p = 0.71). Moreover, it showed no statistically significant differences due to the number of stimulation doses (p = 0.71) nor due to the delay after the last stimulation dose (p = 0.96). Obtained results suggest that stimulation at current parameters (50 mA, 200 µs, 300 Hz, biphasic, charge-balanced pulses for 2 minutes) does not induce neuronal damage in the hippocampal CA3 subregion of the brain.


Assuntos
Hipocampo/patologia , Neurônios/patologia , Estado Epiléptico/terapia , Estimulação Transcraniana por Corrente Contínua/instrumentação , Animais , Modelos Animais de Doenças , Eletrodos , Desenho de Equipamento , Masculino , Ratos , Ratos Sprague-Dawley
3.
IEEE Trans Neural Syst Rehabil Eng ; 20(4): 422-31, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22772373

RESUMO

Epilepsy affects approximately 1% of the world population. Antiepileptic drugs are ineffective in approximately 30% of patients and have side effects. We are developing a noninvasive, or minimally invasive, transcranial focal electrical stimulation system through our novel tripolar concentric ring electrodes to control seizures. In this study, we demonstrate feasibility of an automatic seizure control system in rats with pentylenetetrazole-induced seizures through single and multiple stimulations. These stimulations are automatically triggered by a real-time electrographic seizure activity detector based on a disjunctive combination of detections from a cumulative sum algorithm and a generalized likelihood ratio test. An average seizure onset detection accuracy of 76.14% was obtained for the test set (n = 13). Detection of electrographic seizure activity was accomplished in advance of the early behavioral seizure activity in 76.92% of the cases. Automatically triggered stimulation significantly (p = 0.001) reduced the electrographic seizure activity power in the once stimulated group compared to controls in 70% of the cases. To the best of our knowledge this is the first closed-loop automatic seizure control system based on noninvasive electrical brain stimulation using tripolar concentric ring electrode electrographic seizure activity as feedback.


Assuntos
Eletrodos Implantados , Eletroencefalografia/instrumentação , Convulsões/diagnóstico , Convulsões/prevenção & controle , Terapia Assistida por Computador/métodos , Estimulação Magnética Transcraniana/instrumentação , Animais , Biorretroalimentação Psicológica , Diagnóstico por Computador/instrumentação , Diagnóstico por Computador/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Ratos , Ratos Sprague-Dawley , Convulsões/fisiopatologia , Terapia Assistida por Computador/instrumentação , Estimulação Magnética Transcraniana/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA