Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Cardiovasc Electrophysiol ; 32(5): 1268-1280, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33570241

RESUMO

BACKGROUND: Catheter ablation is associated with limited success rates in patients with persistent atrial fibrillation (AF). Currently, existing mapping systems fail to identify critical target sites for ablation. Recently, we proposed and validated several techniques (multiscale frequency [MSF], Shannon entropy [SE], kurtosis [Kt], and multiscale entropy [MSE]) to identify pivot point of rotors using ex-vivo optical mapping animal experiments. However, the performance of these techniques is unclear for the clinically recorded intracardiac electrograms (EGMs), due to the different nature of the signals. OBJECTIVE: This study aims to evaluate the performance of MSF, MSE, SE, and Kt techniques to identify the pivot point of the rotor using unipolar and bipolar EGMs obtained from numerical simulations. METHODS: Stationary and meandering rotors were simulated in a 2D human atria. The performances of new approaches were quantified by comparing the "true" core of the rotor with the core identified by the techniques. Also, the performances of all techniques were evaluated in the presence of noise, scar, and for the case of the multielectrode multispline and grid catheters. RESULTS: Our results demonstrate that all the approaches are able to accurately identify the pivot point of both stationary and meandering rotors from both unipolar and bipolar EGMs. The presence of noise and scar tissue did not significantly affect the performance of the techniques. Finally, the core of the rotors was correctly identified for the case of multielectrode multispline and grid catheter simulations. CONCLUSION: The core of rotors can be successfully identified from EGMs using novel techniques; thus, providing motivation for future clinical implementations.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Entropia , Átrios do Coração , Humanos
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 2606-2609, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33018540

RESUMO

Over the last few years, the use of cardiac mapping for effective diagnosis and treatment of arrhythmias has increased significantly. In the clinical environment, electroanatomical mapping (EAM) is performed during the electrophysiological procedures using proprietary systems such as CARTO, EnSite Precision, RHYTHMIA, etc. These systems generate the 3D model of patient-specific atria with the electrical activity (i.e., intracardiac electrograms (iEGMs)) displayed on it, for further identification of the sources of arrhythmia and for guiding cardiac ablation therapy. Recently, several novel techniques were developed to perform iEGMs analysis to more accurately identify the arrhythmogenic sites. However, there is a difficulty in incorporating the results of iEGMs analysis back to EAM systems due to their proprietary constraints. This created a hurdle in the further development of novel techniques to help navigate patient-specific clinical ablation therapy. Thus, we developed an open source software, VIEgram1, that allows researchers to visualize the results of the various iEGMs analysis on a patient-specific 3D atria model. It eliminates the dependency of the academic environment on the proprietary EAM systems, thereby making the process of retrospective mapping extremely convenient and time efficient. Here, we demonstrate the features of VIEgram such as visual inspection of iEGMs, flexibility in implementing custom iEGMs analysis techniques and interpolation schemes, and spatial analysis.


Assuntos
Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Arritmias Cardíacas/diagnóstico , Átrios do Coração , Humanos , Estudos Retrospectivos
3.
J Cardiovasc Electrophysiol ; 31(12): 3106-3114, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32955151

RESUMO

INTRODUCTION: The need for transparency in financial relationships in the healthcare system, has culminated in Open Payments database, managed by the Center for Medicare and Medicaid Services (CMS). Since its inception in 2013, the trend in such payments to physicians practicing cardiac electrophysiology was not examined. METHODS AND RESULTS: Payment information reported to CMS from January 2013 to December 2018 was obtained from the publicly available Open Payments data set using the online query tool. The data were analyzed by an individual provider and by state. An in-depth analysis of payments in the year 2018 payments was performed. From 2014 to 2018, there was an 18% increase in the total number of payments reported from 88 877 payments in 2014 to 105 000 in 2018. Despite the increase in the total number of payments reported, the average payment steadily decreased over time, resulting in an overall reduction in the total amount of payments from 2014 to 2018 ($34.9 million to $28.2 million). Payments to the top 5% of individual recipients have also decreased over this time. In 2018, 2888 unique providers received reportable payments, a total of 105 000 payments, with a median payment amount of $1378 (interquartile range: $165-$5781). The majority of these payments were for food and beverage (82%) and travel/lodging (10%). The top five payers include Boston Scientific, Medtronic Vascular, Abbott Laboratories, Janssen Pharmaceuticals, and Biotronik. CONCLUSION: Among cardiac electrophysiologists, there is increased reporting of payments in the Open Payments program over time, with a notable decrease in the payment amount.


Assuntos
Conflito de Interesses , Médicos , Idoso , Boston , Técnicas Eletrofisiológicas Cardíacas , Humanos , Medicare , Estados Unidos
4.
J Cardiovasc Electrophysiol ; 30(12): 2920-2928, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31625219

RESUMO

BACKGROUND: Inappropriate sinus tachycardia (IST) remains a clinical challenge because patients often are highly symptomatic and not responsive to medical therapy. OBJECTIVE: To study the safety and efficacy of stellate ganglion (SG) block and cardiac sympathetic denervation (CSD) in patients with IST. METHODS: Twelve consecutive patients who had drug-refractory IST (10 women) were studied. According to a prospectively initiated protocol, five patients underwent an electrophysiologic study before and after SG block (electrophysiology study group). The subsequent seven patients had ambulatory Holter monitoring before and after SG block (ambulatory group). All patients underwent SG block on the right side first, and then on the left side. Selected patients who had heart rate reduction ≥15 beats per minute (bpm) were recommended to consider CSD. RESULTS: The mean (SD) baseline heart rate (HR) was 106 (21) bpm. The HR significantly decreased to 93 (20) bpm (P = .02) at 10 minutes after right SG block and remained significantly slower at 97(19) bpm at 60 minutes. Left SG block reduced HR from 99 (21) to 87(16) bpm (P = .02) at 60 minutes. SG block had no significant effect on blood pressure or HR response to isoproterenol or exercise (all P > .05). Five patients underwent right (n = 4) or bilateral (n = 1) CSD. The clinical outcomes were heterogeneous: one patient had complete and two had partial symptomatic relief, and two did not have improvement. CONCLUSION: SG blockade modestly reduces resting HR but has no significant effect on HR during exercise. Permanent CSD may have a modest role in alleviating symptoms in selected patients with IST.


Assuntos
Anestésicos Combinados/administração & dosagem , Anestésicos Locais/administração & dosagem , Bloqueio Nervoso Autônomo , Bupivacaína/administração & dosagem , Frequência Cardíaca/efeitos dos fármacos , Coração/inervação , Lidocaína/administração & dosagem , Gânglio Estrelado/efeitos dos fármacos , Simpatectomia , Taquicardia Sinusal/terapia , Adulto , Anestésicos Combinados/efeitos adversos , Anestésicos Locais/efeitos adversos , Bloqueio Nervoso Autônomo/efeitos adversos , Bupivacaína/efeitos adversos , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Lidocaína/efeitos adversos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Gânglio Estrelado/fisiopatologia , Simpatectomia/efeitos adversos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
5.
J Cardiovasc Electrophysiol ; 30(9): 1679-1687, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31332867

RESUMO

BACKGROUND AND OBJECTIVES: Macroreentrant atrial tachycardias often occur following atrial fibrillation ablation, most commonly due to nontransmural lesions in prior ablation lines. Perimitral atrial flutter is one such arrhythmia which requires ablation of the mitral isthmus. Our objectives were to review the literature regarding ablation of the mitral isthmus and to provide our approach for assessment of mitral isthmus block. METHODS: We review anatomical considerations, ablation strategies, and assessment of conduction block across the mitral isthmus, which is subject to several pitfalls. Activation sequence and spatial differential pacing techniques are discussed for assessment of both endocardial and epicardial bidirectional mitral isthmus block. RESULTS: Traditional methods for verifying mitral isthmus block include spatial differential pacing, activation mapping, and identification of double potentials. Up to 70% of cases require additional ablation in the coronary sinus (CS) to achieve transmural block. Interpretation of transmural block is subject to six pitfalls involving pacing output, differentiation of endocardial left atrial recordings from epicardial CS recordings, identification of a slowly conducting gap in the line, and catheter positioning during spatial differential pacing. Interpretation of unipolar electrograms can identify nontransmural lesions. We employ a combined epicardial and endocardial assessment of mitral isthmus block, which involves using a CS catheter for epicardial recording and a duodecapolar Halo catheter positioned around the mitral annulus for endocardial recording. CONCLUSIONS: The assessment of transmural mitral isthmus block can be challenging. Placement of an endocardial mapping catheter around the mitral annulus can provide a precise assessment of conduction across the mitral isthmus.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Valva Mitral/cirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Frequência Cardíaca , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Resultado do Tratamento
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 5986-5989, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30441700

RESUMO

Atrial Fibrillation (AF) is most common cardiac arrhythmia. It is associated with increased risk of stroke, heart failure and sudden cardiac death. Catheter ablation is a treatment used to control AF and has had suboptimal success for patients with persistent AF, which is primarily maintained by rotors outside of the pulmonary veins (PV) region. The pivot point (core) of the rotor is considered an efficient target for ablation. Currently available electro-anatomical mapping systems cannot accurately predict the exact location of the pivot point of rotors outside of the PV region, so there is a need for novel approaches to accurately identify and distinguish sites for ablation. Recently, a multiscale frequency (MSF) technique was developed for accurate identification of the pivot point of rotors and validated using optical mapping experiments in exvivo rabbit hearts, where electrical activity can be directly visualized. However, the nature of optical signals and its spatial resolution are very different from clinical intracardiac electrograms (iEGM). Here we extend the MSF approach to 3D iEGM and compare its prediction with the traditional dominant frequency (DF) approach, using Pearson's correlation and earth mover's distance methods. Our results demonstrate that the similarity between MSF and DF are high in some regions, but very low in other spatial regions of the human atria. This indicates the inconsistency in the traditional DF approach in identifying pivot points and identifying such low similarity regions can be used to find sites for successful ablation.


Assuntos
Fibrilação Atrial/diagnóstico , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Veias Pulmonares/diagnóstico por imagem , Animais , Átrios do Coração , Humanos , Coelhos
7.
Circulation ; 137(1): 24-33, 2018 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-29046320

RESUMO

BACKGROUND: Recognition of rates and causes of hard, patient-centered outcomes of death and cerebrovascular events (CVEs) after heart rhythm disorder management (HRDM) procedures is an essential step for the development of quality improvement programs in electrophysiology laboratories. Our primary aim was to assess and characterize death and CVEs (stroke or transient ischemic attack) after HRDM procedures over a 17-year period. METHODS: We performed a retrospective cohort study of all patients undergoing HRDM procedures between January 2000 and November 2016 at the Mayo Clinic. Patients from all 3 tertiary academic centers (Rochester, Phoenix, and Jacksonville) were included in the study. All in-hospital deaths and CVEs after HRDM procedures were identified and were further characterized as directly or indirectly related to the HRDM procedure. Subgroup analysis of death and CVE rates was performed for ablation, device implantation, electrophysiology study, lead extraction, and defibrillation threshold testing procedures. RESULTS: A total of 48 913 patients (age, 65.7±6.6 years; 64% male) who underwent a total of 62 065 HRDM procedures were included in the study. The overall mortality and CVE rates in the cohort were 0.36% (95% confidence interval [CI], 0.31-0.42) and 0.12% (95% CI, 0.09-0.16), respectively. Patients undergoing lead extraction had the highest overall mortality rate at 1.9% (95% CI, 1.34-2.61) and CVE rate at 0.62% (95% CI, 0.32-1.07). Among patients undergoing HRDM procedures, 48% of deaths directly related to the HDRM procedure were among patients undergoing device implantation procedures. Overall, cardiac tamponade was the most frequent direct cause of death (40%), and infection was the most common indirect cause of death (29%). The overall 30-day mortality rate was 0.76%, with the highest being in lead extraction procedures (3.08%), followed by device implantation procedures (0.94%). CONCLUSIONS: Half of the deaths directly related to an HRDM procedure were among the patients undergoing device implantation procedures, with cardiac tamponade being the most common cause of death. This highlights the importance of the development of protocols for the quick identification and management of cardiac tamponade even in procedures typically believed to be lower risk such as device implantation.


Assuntos
Arritmias Cardíacas/terapia , Procedimentos Cirúrgicos Cardíacos/mortalidade , Mortalidade Hospitalar , Ataque Isquêmico Transitório/mortalidade , Acidente Vascular Cerebral/epidemiologia , Técnicas de Ablação/mortalidade , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/tendências , Tamponamento Cardíaco/mortalidade , Causas de Morte , Desfibriladores Implantáveis , Remoção de Dispositivo/mortalidade , Técnicas Eletrofisiológicas Cardíacas/mortalidade , Feminino , Mortalidade Hospitalar/tendências , Humanos , Ataque Isquêmico Transitório/diagnóstico , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Implantação de Prótese/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
8.
J Cardiovasc Electrophysiol ; 28(1): 68-77, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27766717

RESUMO

BACKGROUND: Patients with advanced heart failure (HF) are predisposed to ventricular arrhythmias (VAs), particularly following implantation of a left ventricular assist device (LVAD). There is minimal evidence for appropriate management strategies. OBJECTIVES: This study aimed to compare the burden of VA and response to ablation performed either before or following LVAD implantation. METHODS: We created a retrospective cohort of patients who underwent both VA ablation and Heart Mate II (Thoratec, Pleasanton, CA, USA) LVAD implantation at Mayo Clinic (Rochester, MN, USA). Patients were stratified based on whether they underwent VA ablation before (pre-LVAD) or after LVAD (post-LVAD) implantation. Descriptive analyses assessed 6-month arrhythmia burden in relation to LVAD implantation and VA ablation. RESULTS: A total of 9 patients underwent both LVAD implantation and VA ablation. There were 3 and 6 patients, respectively, in the pre-LVAD and post-LVAD cohorts. Among patients in the pre-LVAD cohort, the median number of VAs tended to increase after ablation (9 vs. 72) and decreased after LVAD implantation (72 vs. 63). Similarly among patients in the post-LVAD cohort, the median burden of VAs increased after LVAD implantation (1 vs. 22) and the median burden decreased after ablation (22 vs. 13). Two of 6 patients had substrate related to the LVAD inflow cannula site, while other substrate was not related directly to the cannula. CONCLUSIONS: In patients with progressive HF and LVAD implantation, ablation is associated with reduced VA rates. In LVAD patients, most VAs arise from substrate unrelated to the inflow cannula site.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter , Insuficiência Cardíaca/terapia , Coração Auxiliar , Função Ventricular Esquerda , Potenciais de Ação , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Biópsia , Ablação por Cateter/efeitos adversos , Ecocardiografia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Ther Adv Cardiovasc Dis ; 9(3): 66-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25731185

RESUMO

BACKGROUND: The addition of electroanatomic mapping to a standard echo-guided endomyocardial biopsy could identify areas of abnormal pathology and increase the diagnostic yield of the procedure. METHODS AND RESULTS: In this demonstration of a novel technique, a 45-year-old woman with clinical suspicion for cardiac sarcoidosis underwent right ventricular bipolar electroanatomical mapping with identification of areas of signal fractionation and low voltage. A bioptome, configured to record an electrogram from the tip, was then visualized on the three-dimensional electroanatomic mapping (3DEAM) system, and directed to these areas. The biopsy was assisted by the use of a steerable introducer sheath, and by recording unipolar and extended bipolar signals from the bioptome tip. A prominent change in the signal was detected by the electrode at the bioptome tip when the jaws closed on the endomyocardial tissue. Patient tolerated the procedure without complications, and the biopsied samples were appropriate for pathological analysis. CONCLUSIONS: Using existing technology, the 3DEAM, which integrates unipolar and bipolar signal from the bioptome tip, is feasible, and can be safely added to a standard echocardiographically guided endomyocardial biopsy. Future studies should investigate whether such a technique could increase the safety and diagnostic yield of endomyocardial biopsies in patients with suspected cardiomyopathies.


Assuntos
Biópsia/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Cardiomiopatias/diagnóstico , Técnicas Eletrofisiológicas Cardíacas/métodos , Miocárdio/patologia , Sarcoidose/diagnóstico , Ecocardiografia Tridimensional , Feminino , Humanos , Pessoa de Meia-Idade
11.
J Cardiovasc Electrophysiol ; 25(10): 1115-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24902981

RESUMO

BACKGROUND: Neurocardiogenic syncope (NCS) is a common and sometimes debilitating disorder, with no consistently effective treatment. NCS is due to a combination of bradycardia and vasodilation leading to syncope. Although pacemaker devices have been tried in treating the bradycardic aspect of NCS, no device-based therapy exists to treat the coexistent vasodilation that occurs. The renal sympathetic innervation has been the target of denervation to treat hypertension. We hypothesized that stimulation of the renal sympathetic nerves can increase blood pressure and counteract vasodilation in NCS. METHODS AND RESULTS: High-frequency stimulation (800-900 pps, 10 V, 30-200 seconds) was performed using a quadripolar catheter in the renal vein of 7 dogs and 1 baboon. A significant increase in blood pressure (BP; mean [SD] systolic BP 117 [±28] vs. 128 [±33], diastolic BP 75 [±19] vs. 87 [±29] mmHg) was noted during the stimulation, which returned to baseline after cessation of stimulation. The mean increase in systolic and diastolic BP was 13.0 (±3.3) (P = 0.006) and 10.2 (±4.6) (P = 0.08), respectively. CONCLUSION: We report the first ever study of feasibility and safety of high-frequency electrical stimulation of the renal sympathetic innervation to increase BP in animal models. This has potential applications in the treatment of hypotensive states such as NCS.


Assuntos
Pressão Sanguínea/fisiologia , Terapia por Estimulação Elétrica/métodos , Rim/inervação , Rim/fisiologia , Nervos Periféricos/fisiologia , Veias Renais/fisiologia , Sistema Nervoso Simpático/fisiologia , Síncope Vasovagal/fisiopatologia , Animais , Cães , Estudos de Viabilidade , Papio , Síncope Vasovagal/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA