Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 30(12): 2920-2928, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31625219

RESUMO

BACKGROUND: Inappropriate sinus tachycardia (IST) remains a clinical challenge because patients often are highly symptomatic and not responsive to medical therapy. OBJECTIVE: To study the safety and efficacy of stellate ganglion (SG) block and cardiac sympathetic denervation (CSD) in patients with IST. METHODS: Twelve consecutive patients who had drug-refractory IST (10 women) were studied. According to a prospectively initiated protocol, five patients underwent an electrophysiologic study before and after SG block (electrophysiology study group). The subsequent seven patients had ambulatory Holter monitoring before and after SG block (ambulatory group). All patients underwent SG block on the right side first, and then on the left side. Selected patients who had heart rate reduction ≥15 beats per minute (bpm) were recommended to consider CSD. RESULTS: The mean (SD) baseline heart rate (HR) was 106 (21) bpm. The HR significantly decreased to 93 (20) bpm (P = .02) at 10 minutes after right SG block and remained significantly slower at 97(19) bpm at 60 minutes. Left SG block reduced HR from 99 (21) to 87(16) bpm (P = .02) at 60 minutes. SG block had no significant effect on blood pressure or HR response to isoproterenol or exercise (all P > .05). Five patients underwent right (n = 4) or bilateral (n = 1) CSD. The clinical outcomes were heterogeneous: one patient had complete and two had partial symptomatic relief, and two did not have improvement. CONCLUSION: SG blockade modestly reduces resting HR but has no significant effect on HR during exercise. Permanent CSD may have a modest role in alleviating symptoms in selected patients with IST.


Assuntos
Anestésicos Combinados/administração & dosagem , Anestésicos Locais/administração & dosagem , Bloqueio Nervoso Autônomo , Bupivacaína/administração & dosagem , Frequência Cardíaca/efeitos dos fármacos , Coração/inervação , Lidocaína/administração & dosagem , Gânglio Estrelado/efeitos dos fármacos , Simpatectomia , Taquicardia Sinusal/terapia , Adulto , Anestésicos Combinados/efeitos adversos , Anestésicos Locais/efeitos adversos , Bloqueio Nervoso Autônomo/efeitos adversos , Bupivacaína/efeitos adversos , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Lidocaína/efeitos adversos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Gânglio Estrelado/fisiopatologia , Simpatectomia/efeitos adversos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
2.
Am J Cardiol ; 121(11): 1373-1379, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29580630

RESUMO

In patients with unexplained cardiomyopathy, electroanatomical mapping can identify abnormal tissue to target during electrophysiology-guided endomyocardial biopsy (EP-guided EMB). The objective of this study is to determine whether catheter ablation performed in the same setting as EP-guided EMB increases procedural risk. Sixty-seven patients (mean age 54.4 ± 13.8, 57% male) undergoing EP-guided EMB were included. Radiofrequency catheter ablation was performed in 17 patients (25%) for ventricular arrhythmias and in 2 (3%) for typical atrial flutter. Femoral arterial access was obtained in 90% ablation patients and 40% biopsy-only patients; vascular access complications were more common in the ablation group than in the EMB-only group (p = 0.02). There were no significant differences in rate of tricuspid regurgitation, thromboembolism, or pericardial effusion, whether procedural anticoagulation was used. In conclusion, catheter ablation and procedural anticoagulation can be combined with EP-guided EMB with an increased risk of vascular access complications, but no significant increase in intracardiac complications.


Assuntos
Arritmias Cardíacas/patologia , Biópsia/métodos , Cardiomiopatias/patologia , Ablação por Cateter/métodos , Endocárdio/patologia , Miocardite/patologia , Miocárdio/patologia , Sarcoidose/patologia , Adulto , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/cirurgia , Flutter Atrial/etiologia , Flutter Atrial/patologia , Flutter Atrial/cirurgia , Bloqueio Atrioventricular/patologia , Bloqueio Atrioventricular/cirurgia , Cardiomiopatias/complicações , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocardite/complicações , Complicações Pós-Operatórias/epidemiologia , Sarcoidose/complicações , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/patologia , Complexos Ventriculares Prematuros/cirurgia
5.
Circulation ; 137(1): 24-33, 2018 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-29046320

RESUMO

BACKGROUND: Recognition of rates and causes of hard, patient-centered outcomes of death and cerebrovascular events (CVEs) after heart rhythm disorder management (HRDM) procedures is an essential step for the development of quality improvement programs in electrophysiology laboratories. Our primary aim was to assess and characterize death and CVEs (stroke or transient ischemic attack) after HRDM procedures over a 17-year period. METHODS: We performed a retrospective cohort study of all patients undergoing HRDM procedures between January 2000 and November 2016 at the Mayo Clinic. Patients from all 3 tertiary academic centers (Rochester, Phoenix, and Jacksonville) were included in the study. All in-hospital deaths and CVEs after HRDM procedures were identified and were further characterized as directly or indirectly related to the HRDM procedure. Subgroup analysis of death and CVE rates was performed for ablation, device implantation, electrophysiology study, lead extraction, and defibrillation threshold testing procedures. RESULTS: A total of 48 913 patients (age, 65.7±6.6 years; 64% male) who underwent a total of 62 065 HRDM procedures were included in the study. The overall mortality and CVE rates in the cohort were 0.36% (95% confidence interval [CI], 0.31-0.42) and 0.12% (95% CI, 0.09-0.16), respectively. Patients undergoing lead extraction had the highest overall mortality rate at 1.9% (95% CI, 1.34-2.61) and CVE rate at 0.62% (95% CI, 0.32-1.07). Among patients undergoing HRDM procedures, 48% of deaths directly related to the HDRM procedure were among patients undergoing device implantation procedures. Overall, cardiac tamponade was the most frequent direct cause of death (40%), and infection was the most common indirect cause of death (29%). The overall 30-day mortality rate was 0.76%, with the highest being in lead extraction procedures (3.08%), followed by device implantation procedures (0.94%). CONCLUSIONS: Half of the deaths directly related to an HRDM procedure were among the patients undergoing device implantation procedures, with cardiac tamponade being the most common cause of death. This highlights the importance of the development of protocols for the quick identification and management of cardiac tamponade even in procedures typically believed to be lower risk such as device implantation.


Assuntos
Arritmias Cardíacas/terapia , Procedimentos Cirúrgicos Cardíacos/mortalidade , Mortalidade Hospitalar , Ataque Isquêmico Transitório/mortalidade , Acidente Vascular Cerebral/epidemiologia , Técnicas de Ablação/mortalidade , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/tendências , Tamponamento Cardíaco/mortalidade , Causas de Morte , Desfibriladores Implantáveis , Remoção de Dispositivo/mortalidade , Técnicas Eletrofisiológicas Cardíacas/mortalidade , Feminino , Mortalidade Hospitalar/tendências , Humanos , Ataque Isquêmico Transitório/diagnóstico , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Implantação de Prótese/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
6.
J Cardiovasc Electrophysiol ; 28(1): 68-77, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27766717

RESUMO

BACKGROUND: Patients with advanced heart failure (HF) are predisposed to ventricular arrhythmias (VAs), particularly following implantation of a left ventricular assist device (LVAD). There is minimal evidence for appropriate management strategies. OBJECTIVES: This study aimed to compare the burden of VA and response to ablation performed either before or following LVAD implantation. METHODS: We created a retrospective cohort of patients who underwent both VA ablation and Heart Mate II (Thoratec, Pleasanton, CA, USA) LVAD implantation at Mayo Clinic (Rochester, MN, USA). Patients were stratified based on whether they underwent VA ablation before (pre-LVAD) or after LVAD (post-LVAD) implantation. Descriptive analyses assessed 6-month arrhythmia burden in relation to LVAD implantation and VA ablation. RESULTS: A total of 9 patients underwent both LVAD implantation and VA ablation. There were 3 and 6 patients, respectively, in the pre-LVAD and post-LVAD cohorts. Among patients in the pre-LVAD cohort, the median number of VAs tended to increase after ablation (9 vs. 72) and decreased after LVAD implantation (72 vs. 63). Similarly among patients in the post-LVAD cohort, the median burden of VAs increased after LVAD implantation (1 vs. 22) and the median burden decreased after ablation (22 vs. 13). Two of 6 patients had substrate related to the LVAD inflow cannula site, while other substrate was not related directly to the cannula. CONCLUSIONS: In patients with progressive HF and LVAD implantation, ablation is associated with reduced VA rates. In LVAD patients, most VAs arise from substrate unrelated to the inflow cannula site.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter , Insuficiência Cardíaca/terapia , Coração Auxiliar , Função Ventricular Esquerda , Potenciais de Ação , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Biópsia , Ablação por Cateter/efeitos adversos , Ecocardiografia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
JACC Clin Electrophysiol ; 3(13): 1580-1591, 2017 12 26.
Artigo em Inglês | MEDLINE | ID: mdl-29759841

RESUMO

OBJECTIVES: The goal of this study was to evaluate whether prolonged ventricular conduction (paced QRS) and repolarization (paced QTc) times observed during ventricular stimulation predict ventricular arrhythmic events and death. BACKGROUND: Abnormal ventricular conduction and repolarization can predispose patients to ventricular arrhythmias. METHODS: Consecutive patients with left ventricular dysfunction (ejection fraction <50%) undergoing electrophysiology studies from January 2002 until May 2014 were identified at Mayo Clinic (Rochester, Minnesota). Patients were followed up until December 2014 for occurrence of ventricular arrhythmias and death. RESULTS: Among the 501 patients included (mean age 65 years; mean left ventricular ejection fraction 33.1%), longer paced ventricular conduction was associated with longer baseline QRS duration, longer QT interval, and lower ejection fraction. On multivariable analysis, longer paced QRS duration was associated with higher risk of ventricular arrhythmia (hazard ratio [HR]: 1.11 per 10-ms increase; 95% confidence interval [CI]: 1.07 to 1.16; p < 0.001) and all-cause death or arrhythmia (HR: 1.09; 95% CI: 1.09 to 1.13; p < 0.001). A paced QRS duration >190 ms was associated with a 3.6 times higher risk of ventricular arrhythmia (HR: 3.6; 95% CI: 2.35 to 5.53; p < 0.001) and a 2.1 times higher risk of death or arrhythmia (HR: 2.12; 95% CI: 1.53 to 2.95; p < 0.001), independent of left ventricular function or baseline QRS duration. Longer QTc interval during ventricular pacing was associated with a higher risk of ventricular arrhythmia (HR: 1.03 per 10-ms increase; 95% CI: 1.02 to 1.12; p < 0.001) independent of paced QRS duration. CONCLUSIONS: Longer paced QRS duration and paced QTc interval predict ventricular arrhythmias in patients with cardiomyopathy. Ventricular conduction and repolarization prolongation during right ventricular pacing can determine the risk of ventricular arrhythmias.


Assuntos
Cardiomiopatias/diagnóstico , Sistema de Condução Cardíaco/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Fibrilação Ventricular/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Cardiomiopatias/complicações , Cardiomiopatias/epidemiologia , Cardiomiopatias/fisiopatologia , Morte Súbita Cardíaca/prevenção & controle , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Feminino , Sistema de Condução Cardíaco/anormalidades , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Valor Preditivo dos Testes , Prevenção Primária , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Disfunção Ventricular Esquerda/mortalidade , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/prevenção & controle
8.
J Am Heart Assoc ; 5(2)2016 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-26857070

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a common, growing, and costly medical condition. We aimed to evaluate the impact of a management algorithm for symptomatic AF that used an emergency department observation unit on hospital admission rates and patient outcomes. METHODS AND RESULTS: This retrospective cohort study compared 563 patients who presented consecutively in the year after implementation of the algorithm, from July 2013 through June 2014 (intervention group), with 627 patients in a historical cohort (preintervention group) who presented consecutively from July 2011 through June 2012. All patients who consented to have their records used for chart review were included if they had a primary final emergency department diagnosis of AF. We observed no significant differences in age, sex, vital signs, body mass index, or CHADS2 (congestive heart failure, hypertension, age, diabetes mellitus, and prior stroke or transient ischemic attack) score between the preintervention and intervention groups. The rate of inpatient admission was significantly lower in the intervention group (from 45% to 36%; P<0.001). The groups were not significantly different with regard to rates of return emergency department visits (19% versus 17%; P=0.48), hospitalization (18% versus 16%; P=0.22), or adverse events (2% versus 2%; P=0.95) within 30 days. Emergency department observation unit admissions were 40% (P<0.001) less costly than inpatient hospital admissions of ≤1 day's duration. CONCLUSIONS: Implementation of an emergency department observation unit AF algorithm was associated with significantly decreased hospital admissions without increasing the rates of return emergency department visits, hospitalization, or adverse events within 30 days.


Assuntos
Algoritmos , Fibrilação Atrial/terapia , Serviço Hospitalar de Cardiologia/organização & administração , Procedimentos Clínicos/organização & administração , Prestação Integrada de Cuidados de Saúde/organização & administração , Serviço Hospitalar de Emergência/organização & administração , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Técnicas de Apoio para a Decisão , Cardioversão Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Observação , Admissão do Paciente , Equipe de Assistência ao Paciente/organização & administração , Readmissão do Paciente , Valor Preditivo dos Testes , Avaliação de Programas e Projetos de Saúde , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
11.
Circ Arrhythm Electrophysiol ; 8(6): 1522-51, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26386016
12.
Pacing Clin Electrophysiol ; 38(3): 383-90, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25583074

RESUMO

OBJECTIVES: To determine the frequency and predictors of pericardial effusion following epicardial sheath removal. BACKGROUND: Pericardial effusion can occur following cardiac surgical or interventional procedures including percutaneous epicardial access (EpiAcc), which is increasingly used as part of electrophysiology ablation procedures. METHODS: A retrospective analysis of the Mayo Clinic comprehensive electronic medical record was performed from all patients who underwent planned EpiAcc as part of an electrophysiology ablation procedure between January 1, 2004 and June 30, 2013. RESULTS: Of 144 patients (mean age 51.3 ± 15.5 years, 68% male) who underwent planned EpiAcc as part of an electrophysiology ablation (95.8% pericardial access success rate), seven (4.9%) developed a postoperative pericardial effusion requiring repeat EpiAcc. Inferior access was utilized in 74 (51.4%) patients. Patients with pericardial effusion tended to be younger (41.1 years vs 51.8 years, P = 0.08) and were more likely to have undergone inferior approach access (85.7% vs 49.6%, P = 0.06) than those who did not develop postoperative pericardial effusion. Seventy-one percent of patients with postoperative pericardial effusion versus 32.1% of patients without postoperative pericardial effusion had a preprocedure ejection fraction ≥55% (P = 0.03). There were no procedural-related deaths, and no difference in mortality between groups. CONCLUSIONS: Postoperative pericardial effusion requiring repeat access/drainage was relatively infrequent, occurring in 4.9% of patients shortly after epicardial procedures. While the majority occur early and therefore require close observation, some patients may present in a delayed manner.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Cardiopatias/terapia , Derrame Pericárdico/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Drenagem , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
13.
J Cardiovasc Electrophysiol ; 26(2): 158-63, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25425429

RESUMO

INTRODUCTION: Catheter ablation of ventricular arrhythmia (VA) at the fibrous aortic mitral continuity (AMC) has been described, yet the nature of the arrhythmogenic substrate remains unknown. METHODS: Procedural records of 528 consecutive patients undergoing ablation of VA at Mayo Clinic, Rochester, MN, were reviewed. The electrocardiographic and electrophysiologic characteristics of patients with successful ablation at the AMC were analyzed to characterize the underlying arrhythmogenic substrate. RESULTS: Of the 21 patients (mean age 53.2 ± 13.4 years, 47.6% male) who underwent ablation of VA at the AMC with acute success, prepotentials (PPs) were found at the ablation sites preceding the ventricular electrogram (VEGM) during arrhythmias in 13 (61.9%) patients and during sinus rhythm in 7 (53.8%) patients. VAs with PPs were associated with a significantly higher burden of premature ventricular complexes (PVCs; 26.1 ± 10.9% vs. 14.9 ± 10.1%, P = 0.03), shorter VEGM to QRS intervals (9.0 ± 28.5 milliseconds vs. 33.1 ± 8.8 milliseconds, P = 0.03), lower pace map scores (8.7 ± 1.6 vs. 11.4 ± 0.8, P = 0.001), and a trend toward shorter V-H intervals during VA (32.1 ± 38.6 milliseconds vs. 76.3 ± 11.1 milliseconds, P = 0.06) as compared to those without PP. A strong and positive correlation was found between V-H interval and QRS duration during arrhythmia in those with PPs (B = 2.11, R(2) = 0.97, t = 13.7, P < 0.001) but not in those without PPs. CONCLUSION: Local EGM characteristics and relative activation time of the His bundle suggest the possibility of conduction tissue as the origin for VA arising from the fibrous AMC. Specific identification and targeting of PPs when ablating VAs at this location may improve procedural success.


Assuntos
Valva Aórtica/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Valva Mitral/fisiopatologia , Taquicardia Ventricular/diagnóstico , Complexos Ventriculares Prematuros/diagnóstico , Potenciais de Ação , Adulto , Idoso , Valva Aórtica/cirurgia , Fascículo Atrioventricular/fisiopatologia , Ablação por Cateter , Eletrocardiografia , Feminino , Sistema de Condução Cardíaco/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota , Valva Mitral/cirurgia , Valor Preditivo dos Testes , Estudos Retrospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
14.
J Am Coll Cardiol ; 60(9): 851-60, 2012 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-22726633

RESUMO

OBJECTIVES: The authors sought to characterize the left atrial (LA) and pulmonary vein (PV) electrophysiological and hemodynamic features in obese patients with atrial fibrillation (AF). BACKGROUND: Obesity is associated with increased risk for AF. METHODS: A total of 63 consecutive patients with AF who had normal left ventricular (LV) ejection fraction and who underwent catheter ablation were studied. Atrial and PV electrophysiological studies were performed at the time of ablation with hemodynamic assessment by cardiac catheterization, and LA/LV structure and function by echocardiography. Patients were compared on the basis of body mass index (BMI): <25 kg/m(2) (n = 19) and BMI ≥30 kg/m(2) (n = 44). RESULTS: At a 600-ms pacing cycle length, obese patients had shorter effective refractory period (ERP) in the left atrium (251 ± 25 ms vs. 233 ± 32 ms, p = 0.04), and in the proximal (207 ± 33 ms vs. 248 ± 34 ms, p < 0.001) and distal (193 ± 33 ms vs. 248 ± 44 ms, p < 0.001) PV than normal BMI patients. Obese patients had higher mean LA pressure (15 ± 5 mm Hg vs. 10 ± 5 mm Hg, p < 0.001) and LA volume index (28 ± 12 ml/m(2) vs. 21 ± 14 ml/m(2), p = 0.006), and lower LA strain (5.5 ± 3.1% vs. 8.8 ± 2.8%; p < 0.001) than normal BMI patients. CONCLUSIONS: Increased LA pressure and volume, and shortened ERP in the left atrium and PV are potential factors facilitating and perpetuating AF in obese patients with AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Obesidade/fisiopatologia , Veias Pulmonares/fisiopatologia , Adulto , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Ablação por Cateter , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/fisiopatologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Obesidade/complicações
15.
J Interv Card Electrophysiol ; 30(1): 5-15, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21161573

RESUMO

INTRODUCTION: Certain outflow tract tachyarrhythmias require ablation above the semilunar valves. Understanding of the regional anatomy of these arrhythmogenic sites is required to avoid complications. METHODS AND RESULTS: We examined 603 formalin-fixed autopsy hearts from October 1998 to July 2003. Three hundred forty-two of 603 (57%) had myocardial extensions above the aortic valve, and 446 of 602 (74%) had extensions above the pulmonary valve. Extensions were noted above the aortic right coronary cusp (RCC) in 332 of 603 (55%; 2.8 ± 1.2 mm), left coronary cusp (LCC) in 145 of 603 (24%; 1.5 ± 0.5 mm), and non-coronary/posterior cusp in four of 603 (0.66%; 1.3 ± 0.5 mm; p < 0.0001), intercuspally in 295 of 603 (49%; 2.2 ± 1.1 mm) and into the cusps in 13 of 603 (2.2%). Extensions were noted above the pulmonary right cusp in 360 of 602 (60%; 4.0 ± 2.5 mm), posterior/left cusp in 313 of 602 (52%; 3.6 ± 2.1 mm), and anterior cusp in 268 of 602 (45%; 3.7 ± 2.2 mm; p < 0.0001), intercuspally in 438 of 602 (73%; 3.4 ± 1.8 mm) and into the cusps in ten of 602 (1.7%). The left main coronary artery was closer to the myocardial extensions above the nearest pulmonary valve cusp (posterior) than those above the nearest aortic valve cusp (LCC; 4.8 ± 1.7 vs. 16.3 ± 3.3 mm, p = 0.0005). CONCLUSION: Myocardial extensions are common into the great arteries above the semilunar cusps and intercuspally, and rarely into the cusps themselves. The extensions are larger and more symmetric above the pulmonary cusps as compared to the aortic cusps, the most prominent aortic extensions being above the RCC. The left main coronary artery courses close to the extensions above the posterior pulmonary cusp.


Assuntos
Valva Aórtica/anatomia & histologia , Procedimentos Cirúrgicos Cardíacos , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/anatomia & histologia , Modelos Anatômicos , Modelos Cardiovasculares , Valva Pulmonar/anatomia & histologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Pessoa de Meia-Idade , Adulto Jovem
16.
J Cardiovasc Electrophysiol ; 20(8): 908-15, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19368585

RESUMO

BACKGROUND: Pharmacologic therapies to prevent stroke in atrial fibrillation (AF) have numerous limitations, prompting the development of device-based therapies. We investigated whether an electrogram-based approach using a novel hollow suture can safely capture and ligate the left atrial appendage (LAA). METHODS AND RESULTS: A novel system for closure of the LAA within the confines of the closed pericardium with a single sheath puncture was tested in 4 dogs. The tool used to grasp the appendage was fitted with electrodes and utilized electrical navigation to identify and confirm LAA capture. A hollow suture preloaded with a mechanical support wire to permit its manipulation and fluoroscopic visualization was advanced over the grasper, and the wire removed after the suture was positioned. The LAA was successfully closed in all dogs. In 2 dogs, after closure, a thoracotomy was performed and the LAA amputated without bleeding, confirming closure integrity. Necropsy confirmed closure in all animals. CONCLUSIONS: Using electrical navigation, percutaneous epicardial LAA ligation with a remotely tightened suture was performed successfully within the confines of the intact pericardial space. This technique may allow decreasing the risk of stroke in AF patients without the need for thoracotomy or an endocardially placed prosthetic device.


Assuntos
Apêndice Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Animais , Apêndice Atrial/anatomia & histologia , Apêndice Atrial/fisiologia , Ablação por Cateter/instrumentação , Cães , Técnicas Eletrofisiológicas Cardíacas/instrumentação
17.
J Cardiovasc Electrophysiol ; 20(7): 751-8, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19298561

RESUMO

INTRODUCTION: Defining whether retrograde ventriculoatrial (V-A) conduction is via the AV node (AVN) or an accessory pathway (AP) is important during ablation procedures for supraventricular tachycardia (SVT). With the introduction of ventricular extrastimuli (VEST), retrograde right bundle branch block (RBBB) may occur, prolonging the V-H interval, but only when AV node conduction is present. We hypothesized that when AP conduction was present, the V-A interval would increase less than the V-H interval, whereas with retrograde nodal conduction, the V-A interval would increase at least as much as the V-H interval. METHODS AND RESULTS: We retrospectively reviewed the electrophysiological studies of patients undergoing ablation for AVN reentrant tachycardia (AVNRT) (55) or AVRT (50), for induction of retrograde RBBB during the introduction of VEST, and the change in the measured V-H and V-A intervals. Results were found to be reproducible between independent observers. Out of 105 patients, 84 had evidence of induced retrograde RBBB. The average V-H interval increase with induction of RBBB was 53.7 ms for patients with AVRT and 54.4 ms for patients with AVNRT (P = NS). The average V-A interval increase with induction of RBBB was 13.6 ms with AVRT and 70.1 ms with AVNRT (P < 0.001). All patients with a greater V-H than V-A interval change had AVRT, and those with a smaller had AVNRT. CONCLUSIONS: Induction of retrograde RBBB during VEST is common during an electrophysiological study for SVT. The relative change in the intervals during induction of RBBB accurately differentiates between retrograde AVN and AP conduction.


Assuntos
Nó Atrioventricular/fisiopatologia , Bloqueio de Ramo/diagnóstico , Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia Reciprocante/diagnóstico , Taquicardia Supraventricular/diagnóstico , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/cirurgia , Ablação por Cateter , Diagnóstico Diferencial , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Reciprocante/fisiopatologia , Taquicardia Reciprocante/cirurgia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Fatores de Tempo
18.
J Cardiovasc Electrophysiol ; 20(3): 280-3, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19261039

RESUMO

INTRODUCTION: Emergency pericardiocentesis during electrophysiology procedures is often associated with significant aspiration of pericardial blood, requiring transfusion. We sought to assess the feasibility of urgent use of an autologous blood recovery system in the electrophysiology laboratory to autotransfuse blood aspirated from the pericardium. METHODS AND RESULTS: We retrospectively analyzed Mayo Clinic electrophysiology records for patients who had ablation procedure-related pericardial effusions requiring emergency pericardial drainage during an 8-month period. An autologous blood recovery system was used during pericardiocentesis to separate and clean packed red blood cells from the pericardial aspirate. These cells were returned acutely to the patient intravenously. The procedural safety, aspirated and autotransfused volumes, and efficacy of this approach were evaluated. During the study period, nine patients underwent pericardial drainage with autotransfusion using a cell-salvage instrument during electrophysiology procedures. The mean aspirated volume was 1,078 mL, with a mean autotransfused volume of 390 mL. For four patients, all with aspirated volumes of 1,100 mL or less, autotransfusion alone was sufficient to maintain hemodynamic stability and avoid allogeneic transfusion. One patient required surgical intervention because of ongoing pericardial bleeding. The ablation procedure was completed after aspiration in two patients. No procedural complications related to the use of the cell-salvage system occurred. CONCLUSION: Autologous blood recovery during pericardiocentesis is safe, convenient, and feasible. With early use it may decrease or eliminate the need for allogeneic blood transfusion and, in selected cases, may permit completion of the ablation procedure.


Assuntos
Remoção de Componentes Sanguíneos/instrumentação , Transfusão de Sangue Autóloga/instrumentação , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/prevenção & controle , Ablação por Cateter/efeitos adversos , Derrame Pericárdico/etiologia , Derrame Pericárdico/terapia , Pericardiocentese/instrumentação , Adulto , Idoso , Transfusão de Sangue Autóloga/métodos , Serviços Médicos de Emergência/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pericardiocentese/métodos , Estudos Retrospectivos , Resultado do Tratamento
19.
Circ Arrhythm Electrophysiol ; 1(1): 30-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19808391

RESUMO

BACKGROUND: Outflow tract ventricular tachycardia originating above the semilunar valves has been reported in a small number of studies. Discrete potentials in the great arteries (above the semilunar valves) have been rarely described in patients undergoing electrophysiology evaluation and radiofrequency ablation for ventricular arrhythmias. The mechanisms of these discrete potentials in the great arteries and the utility of such potentials in guiding radiofrequency ablation are unknown. METHODS AND RESULTS: Twelve patients with outflow tract ventricular arrhythmia originating above the semilunar valves with discrete arterial potentials were studied. The clinical characteristics, properties of the arterial potentials, electrophysiological evaluation and ablation, and short- and long-term outcomes were reviewed. Of the twelve patients, 8 (67%) were women. The patients' average age was 41+/-14 years. The average ejection fraction was 0.52+/-0.16 (range: 0.16 to 0.75). Contact mapping in the great artery demonstrated discrete near-field electrograms that were separate from far-field ventricular electrograms in all patients (8 above the pulmonary valve and in 4 the aortic valve). One or more of the following electrophysiological characteristics, supportive of an arrhythmogenic substrate, were observed in 10 of 12 patients: (1) A fixed or reproducibly variable pattern of discrete potential-ventricular arrhythmia relationship was present at baseline or during pacing; (2) the discrete potential-ventricular electrogram relationship during sinus rhythm was the reverse of that during the ventricular arrhythmia; (3) during sustained ventricular tachycardia, spontaneous variation of the ventricular (V-V) cycle length was preceded by a similar variation of arterial spike potential-spike potential cycle length; and (4) ablation guided by the discrete arterial potential successfully eliminated the clinical arrhythmia. Ablation was successful in these patients. In the remaining 2 patients, the potentials were believed to be bystanders. Over 10+/-4 months (range: 5 to 32 months) of follow-up, there have been no recurrences of the premature ventricular complex or ventricular arrhythmia. CONCLUSIONS: Discrete potentials are present in the great arteries of a select group of patients with outflow tract ventricular tachycardia originating above the semilunar valves. When an arrhythmogenic relationship can be demonstrated, discrete potentials are useful in guiding ablation within the great vessels, despite significant anatomic complexity.


Assuntos
Aorta/cirurgia , Ablação por Cateter , Artéria Pulmonar/cirurgia , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Adulto , Aorta/fisiopatologia , Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
20.
J Cardiovasc Electrophysiol ; 18(1): 106-9, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17229307

RESUMO

Ventricular tachycardia (VT) in the setting of structural heart disease is challenging to treat with percutaneous catheter ablation due to the presence of complex substrate, multiple morphologies, hemodynamic instability, and epicardial circuits. When substrate-based approaches fail, however, it may be impossible to map and ablate hemodynamically unstable arrhythmias. We describe a novel approach to endocardial and epicardial mapping and ablation of hypotensive VT using a percutaneous left ventricular assist device in the electrophysiology laboratory, permitting near-surgical access to cardiac structures.


Assuntos
Circulação Assistida/métodos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Coração Auxiliar , Hipotensão/complicações , Taquicardia Ventricular/cirurgia , Frequência Cardíaca/fisiologia , Humanos , Hipotensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/complicações , Taquicardia Ventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA