Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ann Surg Oncol ; 30(9): 5597-5609, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37358686

RESUMO

Hyperthermic intraperitoneal chemotherapy (HIPEC) is a treatment modality that aims to target the main site of tumor dissemination in ovarian cancer, the peritoneum, by combining the benefits of intraperitoneal chemotherapy with the synergistic effects of hyperthermia all during a single administration at the time of cytoreductive surgery. High-quality evidence currently only supports the use of HIPEC with cisplatin at the time of interval cytoreduction after neoadjuvant chemotherapy for stage III epithelial ovarian cancer. Many questions remain, including HIPEC's role at other timepoints in ovarian cancer treatment, who are optimal candidates, and specifics of HIPEC protocols. This article reviews the history of normothermic and hyperthermic intraperitoneal chemotherapy in ovarian cancer and evidence regarding HIPEC implementation and patient outcomes. Additionally, this review explores details of HIPEC technique and perioperative care, cost considerations, complication and quality of life data, disparities in HIPEC use, and unresolved issues.


Assuntos
Hipertermia Induzida , Neoplasias Ovarianas , Feminino , Humanos , Quimioterapia Intraperitoneal Hipertérmica , Qualidade de Vida , Hipertermia Induzida/métodos , Neoplasias Ovarianas/tratamento farmacológico , Neoplasias Ovarianas/cirurgia , Carcinoma Epitelial do Ovário/cirurgia , Terapia Combinada , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Procedimentos Cirúrgicos de Citorredução/métodos
2.
J Minim Invasive Gynecol ; 27(6): 1256-1257, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31838277

RESUMO

STUDY OBJECTIVE: To demonstrate a surgical video wherein a robot-assisted colostomy takedown was performed with anastomosis of the descending colon to the rectum after reduction of ventral hernias and extensive lysis of adhesions. DESIGN: Case report and a step-by-step video demonstration of a robot-assisted colostomy takedown and end-to-side anastomosis. SETTING: Tertiary referral center in New Haven, Connecticut. A 64-year-old female was diagnosed with stage IIIA endometrioid endometrial adenocarcinoma in 2015 when she underwent an optimal cytoreductive surgery. In addition, she required resection of the sigmoid colon and a descending end colostomy with Hartmann's pouch, mainly secondary to extensive diverticulitis. After adjuvant chemoradiation, she remained disease free and desired colostomy reversal. Body mass index at the time was 32 kg/m2. Computed tomography of her abdomen and pelvis did not show any evidence of recurrence but was notable for a large ventral hernia and a parastomal hernia. She then underwent a colonoscopy, which was negative for any pathologic condition, except for some narrowing of the distal rectum above the level of the levator ani. INTERVENTIONS: Enterolysis was extensive and took approximately 2 hours. The splenic flexure of the colon had to be mobilized to provide an adequate proximal limb to the anastomosis site. An anvil was then introduced into the distal descending colon through the colostomy site. A robotic stapler was used to seal the colostomy site and detach it from the anterior abdominal wall. Unfortunately, the 28-mm EEA sizer (Covidien, Dublin, Ireland) perforated through the distal rectum, caudal to the stricture site. A substantial length of the distal rectum had to be sacrificed secondary to the perforation, which mandated further mobilization of the splenic flexure. The rectum was then reapproximated with a 3-0 barbed suture in 2 layers. This provided us with approximately 6- to 8-cm distal rectum. An end-to-side anastomosis of the descending colon to the distal rectum was performed. Anastomotic integrity was confirmed using the bubble test. Because of the lower colorectal anastomosis, a protective diverting loop ileostomy was performed. The patient had an uneventful postoperative course. A hypaque enema performed 3 months after the colostomy takedown showed no evidence of anastomotic leak or stricture. The ileostomy was then reversed without any complications. CONCLUSION: Robot-assisted colostomy takedown and anastomosis of the descending colon to rectum were successfully performed. Although there is a paucity of literature examining this technique within gynecologic surgery, the literature on general surgery has supported laparoscopic Hartmann's reversal and has demonstrated improved rates of postoperative complications and incisional hernia and reduced duration of hospitalization [1]. Minimally invasive technique is a feasible alternative to laparotomy for gynecologic oncology patients who undergo colostomy, as long as the patients are recurrence free.


Assuntos
Colostomia/efeitos adversos , Hérnia Ventral/etiologia , Hérnia Ventral/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Aderências Teciduais/etiologia , Aderências Teciduais/cirurgia , Parede Abdominal/cirurgia , Anastomose Cirúrgica/métodos , Fístula Anastomótica/cirurgia , Colo Sigmoide/patologia , Colo Sigmoide/cirurgia , Bolsas Cólicas/efeitos adversos , Colostomia/métodos , Feminino , Humanos , Laparoscopia/métodos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Reoperação/métodos , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA