Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 119(33): e2203287119, 2022 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-35939711

RESUMO

Electrical neuron stimulation holds promise for treating chronic neurological disorders, including spinal cord injury, epilepsy, and Parkinson's disease. The implementation of ultrathin, flexible electrodes that can offer noninvasive attachment to soft neural tissues is a breakthrough for timely, continuous, programable, and spatial stimulations. With strict flexibility requirements in neural implanted stimulations, the use of conventional thick and bulky packages is no longer applicable, posing major technical issues such as short device lifetime and long-term stability. We introduce herein a concept of long-lived flexible neural electrodes using silicon carbide (SiC) nanomembranes as a faradic interface and thermal oxide thin films as an electrical barrier layer. The SiC nanomembranes were developed using a chemical vapor deposition (CVD) process at the wafer level, and thermal oxide was grown using a high-quality wet oxidation technique. The proposed material developments are highly scalable and compatible with MEMS technologies, facilitating the mass production of long-lived implanted bioelectrodes. Our experimental results showed excellent stability of the SiC/silicon dioxide (SiO2) bioelectronic system that can potentially last for several decades with well-maintained electronic properties in biofluid environments. We demonstrated the capability of the proposed material system for peripheral nerve stimulation in an animal model, showing muscle contraction responses comparable to those of a standard non-implanted nerve stimulation device. The design concept, scalable fabrication approach, and multimodal functionalities of SiC/SiO2 flexible electronics offer an exciting possibility for fundamental neuroscience studies, as well as for neural stimulation-based therapies.


Assuntos
Terapia por Estimulação Elétrica , Neuroestimuladores Implantáveis , Nanoestruturas , Semicondutores , Compostos Inorgânicos de Carbono/química , Terapia por Estimulação Elétrica/instrumentação , Membranas Artificiais , Compostos de Silício/química , Dióxido de Silício/química
2.
Anal Chem ; 92(17): 11558-11564, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32583666

RESUMO

Floating cancer cells can survive the programmed death anoikis process after detaching from the extracellular matrix for the anchorage-dependent cells. Purification of viable floating cancer cells is essential for many biomedical studies, such as drug screening and cancer model development. However, the floating cancer cells are mixed with dead cells and debris in the medium supernatant. In this paper, we developed an inertial microfluidic device with sinusoidal microchannels to continuously remove dead cells and debris from viable cells. First, we characterized the differential inertial focusing properties of polystyrene beads in the devices. Then, we investigated the effects of flow rate on inertial focusing of floating MDA-MB-231 cells. At an optimal flow condition, purification of viable cells was performed and the purity of live cells was increased significantly from 19.9% to 76.6%, with a recovery rate of 69.7%. After separation, we studied and compared the floating and adherent MDA-MB-231 cells in terms of cell proliferation, protrusive cellular structure, and the expression of cyclooxygenase (Cox-2) which is related to epithelial-mesenchymal transition (EMT) changes. Meanwhile, drug screening of both floating and adherent cancer cells was conducted using a chemotherapeutic drug, doxorubicin (Dox). The results revealed that the floating cancer cells possess 30-fold acquired chemoresistance as compared to the adherent cancer cells. Furthermore, a three-dimensional (3D) double-cellular coculture model of human mammary fibroblasts (HMF) spheroid and cancer cells using the floating liquid marble technique was developed.


Assuntos
Separação Celular/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Microfluídica/instrumentação , Adesão Celular , Linhagem Celular Tumoral , Proliferação de Células , Células Cultivadas , Técnicas de Cocultura , Doxorrubicina/farmacologia , Avaliação Pré-Clínica de Medicamentos , Ensaios de Seleção de Medicamentos Antitumorais , Desenho de Equipamento , Fibroblastos/citologia , Humanos , Microesferas , Tamanho da Partícula , Prostaglandina-Endoperóxido Sintases/metabolismo
3.
Sensors (Basel) ; 18(6)2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29857584

RESUMO

We present the mixing and merging of two reactive droplets on top of an open surface. A mobile droplet (1.0 M HCl solution + iron oxide particles) is magnetically-actuated to merge with a sessile droplet (1.0 M NaOH + phenolphthalein). The heat from the exothermic reaction is detected by a thermocouple. We vary the droplet volume (1, 5 and 10 µL), the magnet speed (1.86, 2.79, 3.72 and 4.65 mm/s) and the iron oxide concentration (0.010, 0.020 and 0.040 g/mL) to study their influences on the mixing time, peak temperature and cooling time. The sampled recording of these processes are provided as supplementary files. We observe the following trends. First, the lower volume of droplet and higher speed of magnet lead to shorter mixing time. Second, the peak temperature increases and cooling time decreases at the increasing speed of magnet. Third, the peak temperature is similar for bigger droplets, and they take longer to cool down. Finally, we also discuss the limitations of this preliminary study and propose improvements. These observations could be used to improve the sensitivity of the open chamber system in measuring the exothermic reaction of biological samples.

4.
Sensors (Basel) ; 17(9)2017 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-28885595

RESUMO

Flow sensing in hostile environments is of increasing interest for applications in the automotive, aerospace, and chemical and resource industries. There are thermal and non-thermal approaches for high-temperature flow measurement. Compared to their non-thermal counterparts, thermal flow sensors have recently attracted a great deal of interest due to the ease of fabrication, lack of moving parts and higher sensitivity. In recent years, various thermal flow sensors have been developed to operate at temperatures above 500 °C. Microelectronic technologies such as silicon-on-insulator (SOI), and complementary metal-oxide semiconductor (CMOS) have been used to make thermal flow sensors. Thermal sensors with various heating and sensing materials such as metals, semiconductors, polymers and ceramics can be selected according to the targeted working temperature. The performance of these thermal flow sensors is evaluated based on parameters such as thermal response time, flow sensitivity. The data from thermal flow sensors reviewed in this paper indicate that the sensing principle is suitable for the operation under harsh environments. Finally, the paper discusses the packaging of the sensor, which is the most important aspect of any high-temperature sensing application. Other than the conventional wire-bonding, various novel packaging techniques have been developed for high-temperature application.

5.
Lab Chip ; 12(13): 2353-61, 2012 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-22513799

RESUMO

This paper reports a novel method for the rapid determination of vitamin B(12) concentration in a continuous-flow lab-on-a-chip system. This new method is based on luminol-peroxide chemiluminescence (CL) assays for the detection of cobalt(II) ions in vitamin B(12) molecules. The lab-on-a-chip device consisted of two passive micromixers acting as microreactors and a double spiral microchannel network serving as an optical detection region. This system could operate in two modes. In the first mode, samples are acidified and evaluated directly in the microchip. In the second mode, samples are treated externally by acidification prior to detection in the microchip. In the first mode, the linear range obtained was between 1.00 ng ml(-1) to 10 µg ml(-1), R(2) = 0.996, with a relative standard deviation (RSD) of 1.23 to 2.31% (n = 5) and a limit of detection (lod) of 0.368 pg ml(-1). The minimum sample volume required and the analytical time were 30 µl and 3.6 s, respectively. In the second mode, the linear range obtained was between 0.10 ng ml(-1) to 10 µg ml(-1), R(2) = 0.994, with the RSD of 0.90 to 2.32% (n = 6) and a lod of 0.576 pg ml(-1). The minimum sample and the analytical time required were 50 µl and 6 s, respectively. The lab on a chip working in mode II was successfully used for the determination of vitamin B(12) concentrations in nutritional supplemental tablets and hen egg yolks.


Assuntos
Medições Luminescentes/métodos , Vitamina B 12/análise , Animais , Galinhas , Cobalto/análise , Gema de Ovo/química , Peróxido de Hidrogênio/química , Íons/química , Dispositivos Lab-On-A-Chip , Medições Luminescentes/instrumentação , Luminol/química , Técnicas Analíticas Microfluídicas/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA