1.
J Acoust Soc Am ; 122(1): 35-7, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17614461

RESUMO

The induced reduction in the loudness (ILR) of a weaker tone caused by a preceding stronger tone was measured with both tones in the same ear (ipsilateral ILR) and also in opposite ears (contralateral ILR). The two tones were always equal in duration and were presented repeatedly over several minutes. When the tone duration was 200 ms, for 24 listeners the loudness reduction averaged 11 dB under ipsilateral ILR and 6 dB under contralateral ILR. When the duration was 5 ms, ILR was 8 dB whether ipsilateral or contralateral. For each duration, ipsilateral and contralateral ILR were strongly correlated (r around 0.80).


Assuntos
Adaptação Fisiológica , Percepção Sonora/fisiologia , Mascaramento Perceptivo/fisiologia , Estimulação Acústica , Limiar Auditivo , Boston , Testes com Listas de Dissílabos , França , Humanos , Fatores de Tempo