Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Audiol Neurootol ; 24(5): 264-269, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31661682

RESUMO

OBJECTIVE: Our aim was to determine the effect of acute changes in cochlear place of stimulation on cochlear implant (CI) sound quality. DESIGN: In Experiment 1, 5 single-sided deaf (SSD) listeners fitted with a long (28-mm) electrode array were tested. Basal shifts in place of stimulation were implemented by turning off the most apical electrodes and reassigning the filters to more basal electrodes. In Experiment 2, 2 SSD patients fitted with a shorter (16.5-mm) electrode array were tested. Both basal and apical shifts in place of stimulation were implemented. The apical shifts were accomplished by current steering and creating a virtual place of stimulation more apical that that of the most apical electrode. RESULTS: Listeners matched basal shifts by shifting, in the normal-hearing ear, the overall spectrum up in frequency and/or increasing voice pitch (F0). Listeners matched apical shifts by shifting down the overall frequency spectrum in the normal-hearing ear. CONCLUSION: One factor determining CI voice quality is the location of stimulation along the cochlear partition.


Assuntos
Percepção Auditiva/fisiologia , Cóclea/cirurgia , Implante Coclear , Implantes Cocleares , Surdez/reabilitação , Estimulação Acústica , Feminino , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade
2.
Otol Neurotol ; 37(1): 31-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26649603

RESUMO

HYPOTHESIS: Electrode-to-modiolus distance is correlated with clinically programmed stimulation levels. BACKGROUND: Conventional wisdom has long supposed a significant relationship between cochlear implant (CI) stimulation levels and electrode-to-modiolus distance; however, to date, no such formal investigation has been completed. Thus, the purpose of this project was to investigate the relationship between stimulation levels and electrode-to-modiolus distance. A strong correlation between the two would suggest that stimulation levels might be used to estimate electrode-to-modiolus geometry. METHODS: Electrode-to-modiolus distance was determined via CT imaging using validated CI position analysis software in 137 implanted ears from the three manufacturers holding FDA approval in the United States. Analysis included 2,365 total electrodes, with 1,472 from precurved arrays. Distances were compared to clinically programmed C/M levels that were converted to charge units. RESULTS: Mean modiolar distance with perimodiolar and lateral wall electrodes was 0.47 and 1.15 mm, respectively. Mean suprathreshold charge values were significantly different between each manufacturer. When combining all data, we found a moderate positive correlation (r = 0.367, p < 0.01) that was driven both by the different charge values across companies, and that the company with the highest mean charge values only offers straight electrode arrays. When grouped by electrode type, however, we found a weak correlation (r = 0.12, p < 0.01) for perimodiolar array electrodes only. When considering a single array type from any one manufacturer, only one was observed where distance mildly predicted charge. CONCLUSION: Our results suggest that electrode distance minimally contributes to the current level required for suprathreshold stimulation.


Assuntos
Cóclea/anatomia & histologia , Cóclea/cirurgia , Implante Coclear/métodos , Implantes Cocleares , Eletrodos , Estimulação Acústica , Adulto , Estimulação Elétrica , Desenho de Equipamento , Humanos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA