Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Oral Rehabil ; 32(10): 753-8, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16159354

RESUMO

The marginal and internal gaps of ceramic crowns with alumina copings fabricated using a computer-aided design, computer-aided manufacturing system, were evaluated in vivo using silicone materials. Black and white silicone materials were used to record the marginal and internal gaps of 82 In-Ceram crowns before final cementation. The silicone materials were sectioned bucco-lingually and mesio-distally and viewed under a microscope to measure the thickness of the white silicone layer. Sixteen reference points were measured on each specimen. The mean marginal gaps were compared among the anterior, premolar and molar teeth, and the mean gaps at the reference points within the groups were compared by analysis of variance and the Dunnett T3 test. The mean marginal gap was 66.8 mum. There were no differences in marginal gaps among the three groups. In all the groups, the marginal gaps were the smallest, whereas the occlusal gaps were the largest. The mean marginal gaps of the In-Ceram crowns with the alumina copings fabricated using the GN-I system were within the range of clinically acceptable values.


Assuntos
Óxido de Alumínio , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária/métodos , Dente Pré-Molar , Cerâmica , Adaptação Marginal Dentária , Oclusão Dentária , Feminino , Humanos , Masculino , Mandíbula , Maxila , Dente Molar , Elastômeros de Silicone , Preparo Prostodôntico do Dente/métodos
2.
J Oral Rehabil ; 32(7): 526-30, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15975133

RESUMO

This study evaluated the marginal and internal gaps of Procera AllCeram crowns in vivo using silicone materials. Ninety Procera AllCeram crowns were evaluated before final cementation. White and black silicone materials were used to record the marginal and internal fit; then the crowns were sectioned bucco-lingually and mesio-distally to measure the thickness of the silicone layer using a microscope. Sixteen reference points were measured on each specimen. Mean marginal gaps among anterior, premolar and molar teeth, and mean gaps at the reference points within the groups were compared by analysis of variance and Dunnett T3 test. The mean values at the margins were the smallest in all tooth groups, whereas those at the rounded slope of the chamfer were the largest. There were significant differences (P < 0.001) in the mean gaps at the four reference points (margin, rounded slope of the chamfer, axial wall and occlusal surface) in each group, except for the molar teeth. The mean marginal gaps of the Procera AllCeram crowns were within the range of clinical acceptance.


Assuntos
Óxido de Alumínio , Coroas , Porcelana Dentária , Dente Pré-Molar , Cimentação , Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Humanos , Dente Molar
3.
In Vivo ; 13(4): 333-7, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10586374

RESUMO

Saiko-ka-ryukotsu-borei-to (TJ-12) is a traditional Chinese-Japanese medicinal mixture clinically used for the treatment of hypertension and/or atherosclerosis concurrent with neurotic disorders. Study on the effect of TJ-12 on the vasoconstriction of cutaneous arterioles induced by nor-adrenaline (NA) was carried out using a rabbit ear chamber (REC) under conscious conditions. Before and after oral administration of TJ-12 everyday for 2 weeks, the same position of an arteriole within a REC was analyzed using an image shearing monitor every minute up to 15 min after varying doses (0.3, 1.0, 3.0 and 10.0 micrograms/kg i.v.) of NA. The changes of mean arteriolar diameter and vasomotion amplitude, before and after feeding of TJ-12 (1% w/w) supplemented diet were compared in the same position. Consequently, the pretreatment with TJ-12 significantly attenuated the changes of mean diameter of NA-induced vasoconstriction and also shortened its duration. In addition, concurrent with its cutaneous microcirculatory response, the pretreatment with TJ-12 systemically suppressed the increase of blood pressure under NA-induced vasoconstriction. These results suggest that the anti-pressor effect of TJ-12 might be apparently attributable to the inhibition of NA-induced vasoconstriction.


Assuntos
Pressão Sanguínea/efeitos dos fármacos , Medicamentos de Ervas Chinesas/farmacologia , Pele/irrigação sanguínea , Vasoconstrição/efeitos dos fármacos , Animais , Arteríolas/efeitos dos fármacos , Arteríolas/fisiologia , Cultura em Câmaras de Difusão , Relação Dose-Resposta a Droga , Avaliação Pré-Clínica de Medicamentos , Frequência Cardíaca/efeitos dos fármacos , Masculino , Microcirculação/efeitos dos fármacos , Norepinefrina/farmacologia , Coelhos , Pele/efeitos dos fármacos , Fatores de Tempo , Vasoconstrição/fisiologia
5.
J Ethnopharmacol ; 20(2): 107-20, 1987 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3657244

RESUMO

Cutaneous microcirculatory responses to intravenous administration of cepharanthine (CT), a biscoclaurine alkaloid, isolated from Stephania cepharantha, were studied in a transparent round chamber installed in a rabbit ear, under conscious conditions. Vital-microscopic observations were made visually with a microscope-closed TV system and microphotoelectric plethysmography. Following the CT administration in doses of 1.0 and 3.0 mg/kg, an enhancement of rhythmic perfusion of microvascular blood due to vasomotion was developed for a period of 1 h or longer, although no appreciable change was observed following CT administration at 10.0 mg/kg. The microvascular dilator effect of CT appeared to have no direct association with systemic hemodynamics, based on the additional measurements of heart rate, blood pressure, carotid blood flow and auricular arterial blood flow.


Assuntos
Alcaloides/farmacologia , Pele/irrigação sanguínea , Vasodilatadores , Animais , Benzilisoquinolinas , Orelha Externa/irrigação sanguínea , Hemodinâmica/efeitos dos fármacos , Masculino , Microcirculação/efeitos dos fármacos , Fenoxibenzamina/farmacologia , Pletismografia , Coelhos
6.
Acupunct Electrother Res ; 12(1): 45-51, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-2883836

RESUMO

Microcirculatory effects of the application of an acupuncture needle (32-gauge, silver) to the back, corresponding to Geshu (B17) in human beings, were studied in vivo by microscope, using a transparent ear chamber in conscious rabbits. Although no striking findings were obtained during the needle application for a period of 30 minutes, it was clearly observed that the microvascular blood flow increases gradually in parallel with augmenting spontaneous rhythmic fluctuation of the vessel diameter, namely vasomotion, throughout a continuous observation period longer than 2 hours following release from the needle application. Diameters of arterioles and venules at the full-dilating phases of vasomotion reached levels higher than 200% and 250% of the initial values just before application of the needle, respectively. The clinical efficacy of acupuncture was suggested to be explained at least in part by the increased rhythmic microvascular blood flow in parallel with vasomotion, from the physiological point of view based on the previous investigations.


Assuntos
Terapia por Acupuntura , Orelha Externa/irrigação sanguínea , Animais , Hemodinâmica , Masculino , Microcirculação , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA