Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Acad Radiol ; 20(12): 1604-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24200489

RESUMO

RATIONALE AND OBJECTIVES: To investigate the feasibility and performance of 7T magnetic resonance imaging compared to 1.5T imaging to discriminate benign (normal and inflammatory changed) from tumor-bearing lymph nodes in rabbits using ultrasmall particles of iron oxide (USPIO)-based contrast agents. MATERIALS AND METHODS: Six New Zealand White rabbits were inoculated with either complete Freund's adjuvant cell suspension (n = 3) to induce reactively enlarged lymph nodes or with VX2 tumor cells to produce metastatic lymph nodes (n = 3). Image acquisition was performed before and 24 hours after bolus injection of an USPIO contrast agent at 1.5T and afterward at 7T using T1-weighted and T2*-weighted sequences. Sensitivities, specificities, and negative and positive predictive values for the detection of lymph node metastases were calculated for both field strengths with histopathology serving as reference standard. Sizes of lymph nodes with no, inflammatory, and malignant changes were compared using a Mann-Whitney U-test. RESULTS: All 24 lymph nodes were detected at 1.5T as well as at 7T. At 1.5T, sensitivity amounted to 0.67, while specificity reached a value of 1. At the higher field strength (7T), imaging was able to reach sensitivity and specificity values of 1. No statistical differences were detected concerning lymph node sizes. CONCLUSIONS: Magnetic resonance lymphography with USPIO contrast agents allows for differentiation of normal and reactively enlarged lymph nodes compared to metastatic nodes. First experiments at 7T show promising results compared to 1.5T, which have to be evaluated in further trials.


Assuntos
Meios de Contraste , Dextranos , Linfonodos/patologia , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita , Animais , Diagnóstico Diferencial , Modelos Animais de Doenças , Estudos de Viabilidade , Compostos Férricos , Aumento da Imagem/métodos , Metástase Linfática , Magnetismo , Masculino , Variações Dependentes do Observador , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Invest Radiol ; 47(9): 511-5, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22864375

RESUMO

OBJECTIVES: The aim of this study was to investigate the performance of 2 different ultrasmall superparamagnetic iron oxide particles-based contrast agents for intravascular magnetic resonance lymphography in normal, inflammatory, and tumor-bearing lymph nodes in rabbits. MATERIALS AND METHODS: Two USPIO agents were assessed: Sinerem and P904 (both Guerbet Research, Aulnay-sous-Bois, France). Signal change of popliteal and paraaortic lymph nodes were studied in VX-2 tumor-bearing rabbits (n = 4) and rabbits in whom complete Freund adjuvant had been applied (n = 6). Image acquisition was performed before and 5 to 120 minutes and 24 hours after bolus injection of Sinerem (n = 5) and P904 (n = 5). Lymph node size was assessed and signal-to-noise ratios of lymph nodes were calculated. The contrast agents were compared regarding nodal signal changes over time. Furthermore, sensitivities, specificities, and negative and positive predictive values were calculated for both contrast agents, with histopathology serving as the standard of reference. RESULTS: No statistically significant size differences were detected between normal, reactively enlarged and tumor-infiltrated lymph nodes. Signal change over time showed greater differences between benign and metastatic lymph nodes for P904 especially at 24 hours after injection, whereas Sinerem showed the highest signal loss in benign nodes. After 24 hours, P904 showed a higher sensitivity (0.75 vs 0.67) and higher specificity (1 vs 0.94) compared with Sinerem. At earlier time points, sensitivity for Sinerem was lower (0.33), whereas for P904, sensitivity at 120 minutes was as good as after 24 hours (0.75). CONCLUSION: Magnetic resonance lymphography with USPIO contrast agents allows for differentiation of reactively enlarged lymph nodes compared with metastatic nodes. P904 yielded higher sensitivity and specificity values, with higher signal differences between benign and malignant enlarged lymph nodes. Furthermore, diagnosis seems to be possible earlier. This agent therefore seems to be a promising tool for staging cancer patient.


Assuntos
Meios de Contraste , Compostos Férricos , Linfonodos/patologia , Animais , Modelos Animais de Doenças , Metástase Linfática/patologia , Linfografia , Imageamento por Ressonância Magnética , Masculino , Valor Preditivo dos Testes , Coelhos , Sensibilidade e Especificidade , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA