Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur J Pharmacol ; 927: 175052, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35643304

RESUMO

BACKGROUND AND PURPOSE: Chronic pelvic pain syndrome (CPPS) is a common and bothersome condition for which no pharmacological treatment options with acceptable efficacy exist. The aim of this study was to investigate the effects of the soluble guanylate cyclase (sGC) activator BAY 60-2770 and the COX-2 inhibitor celecoxib on bladder function in a rat model of CPPS. EXPERIMENTAL APPROACH: Forty-eight male Sprague-Dawley rats were intraprostatically injected with either saline, serving as control, or zymosan, to induce prostatitis. On days 8-20, the rats were treated with either dimethylsulphoxide (DMSO; vehicle), celecoxib, BAY 60-2770 or a combination of celecoxib and BAY 60-2770. Thereafter, micturition parameters were assessed in a metabolic cage and urine samples were collected. The following day, cystometry was performed. Subsequently, the urinary bladder and prostate were removed and examined histopathologically. KEY RESULTS: Induction of prostatitis led to a significant increase of micturition frequency and corresponding decrease of volume per micturition. These alterations were ameliorated by celecoxib, and completely normalized by BAY 60-2770. Induction of prostatitis led to a significantly increased number of non-voiding contractions, decreased bladder compliance and increased voiding time. These parameters were normalized by treatment with BAY 60-2770, either alone or in combination with celecoxib. The immunohistochemical analysis showed signs of prostate inflammation, but not bladder inflammation. CONCLUSION AND IMPLICATIONS: Induction of prostatitis led to significant impairment in bladder function. These alterations could be prevented by BAY 60-2770, alone or in combination with celecoxib. This is the first study to show that sGC activators could be a promising option for the treatment of CPPS.


Assuntos
Benzoatos , Compostos de Bifenilo , Cistite , Hidrocarbonetos Fluorados , Prostatite , Animais , Benzoatos/farmacologia , Compostos de Bifenilo/farmacologia , Celecoxib/farmacologia , Doença Crônica , Cistite/tratamento farmacológico , Cistite/fisiopatologia , Guanilato Ciclase/metabolismo , Humanos , Hidrocarbonetos Fluorados/farmacologia , Masculino , Dor Pélvica , Prostatite/tratamento farmacológico , Ratos , Ratos Sprague-Dawley , Guanilil Ciclase Solúvel/metabolismo , Bexiga Urinária/efeitos dos fármacos , Bexiga Urinária/fisiopatologia
2.
Mikrochim Acta ; 189(3): 100, 2022 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-35152330

RESUMO

Falsified medicines and healthcare supplements provide a major risk to public health and thus early identification is critical. Although a host of analytical approaches have been used to date, they are limited, as they require extensive sample preparation, are semi-quantitative and/or are inaccessible to low- and middle-income countries. Therefore, for the first time, we report a simple total analysis system which can rapidly and accurately detect falsified medicines and healthcare supplements. We fabricated a poly-lactic acid (PLA) pestle and mortar and using a commercial 3D printer, then made carbon black/PLA (CB/PLA) electrodes in the base of the mortar using a 3D printing pen to make an electrochemical cell. The pestle and mortar were able to crush and grind the tablets into a fine powder to the same consistency as a standard laboratory pestle and mortar. Using melatonin tablets to characterise the device, the 3D-printed pestle and mortar was able to detect the concentration of melatonin in the presence of insoluble excipients. The calibration plot showed a linear response from 37.5 to 300 µg/mL, where the limit of detection was 7 µg/mL. Electrochemical treatment was able to regenerate the CB/PLA working electrode allowing for repeated use of the device. In a blinded study, the device was able to accurately determine falsified melatonin tablets with recovery percentages between 101% and 105%. This was comparable to HPLC measurements. Overall, these findings highlight that our 3D-printed electrochemical pestle and mortar is an accessible and effective total analysis system that can have the ability to identify falsified medicines and healthcare supplements in remote locations.


Assuntos
Depressores do Sistema Nervoso Central/análise , Técnicas Eletroquímicas , Melatonina/análise , Poliésteres/química , Impressão Tridimensional , Eletrodos , Legislação de Medicamentos , Comprimidos
3.
Radiology ; 287(3): 874-883, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29470937

RESUMO

Purpose To investigate the relationship between energy level of virtual monoenergetic (VM) imaging and sensitivity in the detection of minimally enhancing renal lesions. Materials and Methods Phantoms simulating unenhanced and contrast material-enhanced renal parenchyma were equipped with inserts containing different concentrations of iodine (range, 0-1.15 mg iodine per milliliter). A total of 180 patients (117 men; mean age, 65.2 years ± 13.0 [standard deviation]) with 194 (62 solid, 132 cystic) renal lesions larger than 10 mm in diameter underwent unenhanced single-energy CT and contrast-enhanced dual-energy CT. VM imaging data sets were created for 70, 80, 90, and 100 keV. Renal lesions were measured, and enhancement was calculated. Area under the receiver operating characteristic curve (AUC) for renal lesion characterization was determined by using the DeLong method. Results The AUC was highest at 70 keV and decreased as energy increased toward 100 keV. AUC in the phantom decreased from 98% (95% confidence interval [CI]: 95, 100) at 70 keV to 88% (95% CI: 79, 96) at 100 keV (P = .004). AUC in patients decreased from 96% (95% CI: 94, 98) at 70 keV to 79% (95% CI: 71, 86) at 100 keV (P = .001). In patients with an enhancement threshold of 15 HU, sensitivity in the detection of solid renal lesions decreased between from 91% (49 of 62 [95% CI: 78, 97]) at 70 keV to 48% (33 of 62 [95% CI: 25, 71]) at 100 keV (P < .05), with no change in specificity (93% [120 of 132 {95% CI: 87, 97}] at 70 keV, 97% [125 of 132 {95% CI: 92, 99}] at 100 keV). Conclusion There is a reduction in diagnostic accuracy for renal lesion characterization with increasing VM imaging energy. The 70-keV setting may provide an optimal trade-off between sensitivity and specificity. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Meios de Contraste , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Renais/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Iodo , Rim/diagnóstico por imagem , Masculino , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Radiology ; 284(3): 737-747, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28353408

RESUMO

Purpose To determine whether single-phase contrast material-enhanced dual-energy material attenuation analysis improves the characterization of small (1-4 cm) renal lesions compared with conventional attenuation measurements by using histopathologic analysis and follow-up imaging as the clinical reference standards. Materials and Methods In this retrospective, HIPAA-compliant, institutional review board-approved study, 136 consecutive patients (95 men and 41 women; mean age, 54 years) with 144 renal lesions (111 benign, 33 malignant) measuring 1-4 cm underwent single-energy unenhanced and contrast-enhanced dual-energy computed tomography (CT) of the abdomen. For each renal lesion, attenuation measurements were obtained; attenuation change of greater than or equal to 15 HU was considered evidence of enhancement. Dual-energy attenuation measurements were also obtained by using iodine-water, water-iodine, calcium-water, and water-calcium material basis pairs. Mean lesion attenuation values and material densities were compared between benign and malignant renal lesions by using the two-sample t test. Diagnostic accuracy of attenuation measurements and dual-energy material densities was assessed and validated by using 10-fold cross-validation to limit the effect of optimistic bias. Results By using cross-validated optimal thresholds at 100% sensitivity, iodine-water material attenuation images significantly improved specificity for differentiating between benign and malignant renal lesions compared with conventional enhancement measurements (93% [103 of 111]; 95% confidence interval: 86%, 97%; vs 81% [90 of 111]; 95% confidence interval: 73%, 88%) (P = .02). Sensitivity with iodine-water and calcium-water material attenuation images was also higher than that with conventional enhancement measurements, although the difference was not statistically significant. Conclusion Contrast-enhanced dual-energy CT with material attenuation analysis improves specificity for characterization of small (1-4 cm) renal lesions compared with conventional attenuation measurements. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Neoplasias Renais/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Ther Drug Monit ; 34(2): 160-4, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22406650

RESUMO

BACKGROUND: Beta-lactams are first-line antibiotics for the management of superficial infections due to burn injury. There is sparse data available on therapeutic drug monitoring (TDM) in patients with burns in a ward setting. This study was conducted to evaluate the utility of a beta-lactam TDM program in a cohort of burn injury patients in a ward environment. METHODS: Steady-state blood samples were collected immediately before a scheduled dose. The therapeutic concentration targets assessed were (1) free antibiotic concentrations exceeding the minimum inhibitory concentration (MIC; fT > MIC) and (2) free concentrations ≥4× MIC of the known or suspected pathogen (fT > 4× MIC). The duration of therapy was also assessed. RESULTS: A total of 50 patients were included for TDM over a 12-month period. The mean (±SD) age was 49 ± 16 years. The mean percent total body surface area burn was 17 ± 13%. The mean serum creatinine concentration was 86 ± 20 µmole/L. Sixty percent of the patients did not achieve fT > MIC, and only 18% achieved the higher target of fT > 4× MIC. Although all the patients achieved a positive clinical outcome, the duration of antibiotic treatment was shorter in patients who achieved fT > MIC compared with those who did not (4.2 ± 1.1 versus 5.3 ± 2.3 days; P = 0.03). CONCLUSIONS: We found TDM to be a reliable intervention for burn injury patients in a ward environment. This study supports pharmacokinetic data that burns patients may be at risk of subtherapeutic dosing, which may prolong the duration of antibiotic therapy.


Assuntos
Antibacterianos/farmacocinética , Infecções Bacterianas/tratamento farmacológico , Queimaduras/complicações , beta-Lactamas/farmacocinética , Adulto , Idoso , Antibacterianos/administração & dosagem , Antibacterianos/uso terapêutico , Infecções Bacterianas/etiologia , Infecções Bacterianas/microbiologia , Superfície Corporal , Creatinina/sangue , Monitoramento de Medicamentos/métodos , Feminino , Humanos , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , beta-Lactamas/administração & dosagem , beta-Lactamas/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA