Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Heart Rhythm ; 19(1): 137-153, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34371192

RESUMO

Catheter ablation of postinfarction reentrant ventricular tachycardia (VT) has received renewed interest owing to the increased availability of high-resolution electroanatomic mapping systems that can describe the VT circuits in greater detail, and the emergence and need to target noninvasive external beam radioablation. These recent advancements provide optimism for improving the clinical outcome of VT ablation in patients with postinfarction and potentially other scar-related VTs. The combination of analyses gleaned from studies in swine and canine models of postinfarction reentrant VT, and in human studies, suggests the existence of common electroanatomic properties for reentrant VT circuits. Characterizing these properties may be useful for increasing the specificity of substrate mapping techniques and for noninvasive identification to guide ablation. Herein, we describe properties of reentrant VT circuits that may assist in elucidating the mechanisms of onset and maintenance, as well as a means to localize and delineate optimal catheter ablation targets.


Assuntos
Sistema de Condução Cardíaco/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Animais , Ablação por Cateter , Modelos Animais de Doenças , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/cirurgia , Humanos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Taquicardia Ventricular/cirurgia
2.
Am J Cardiol ; 160: 53-59, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34610873

RESUMO

A multivariate risk score model was proposed by Sieira et al in 2017 for sudden death in Brugada syndrome; their validation in 150 patients was highly encouraging, with a C-index of 0.81; however, this score is yet to be validated by an independent group. A total of 192 records of patients with Brugada syndrome were collected from 2 centers in the United Kingdom and retrospectively scored according to a score model by Sieira et al. Data were compiled summatively over follow-up to mimic regular risk re-evaluation as per current guidelines. Sudden cardiac death survivor data were considered perievent to ascertain the utility of the score before cardiac arrest. Scores were compared with actual outcomes. Sensitivity in our cohort was 22.7%, specificity was 57.6%, and C-index was 0.58. In conclusion, up to 75% of cardiac arrest survivors in this cohort would not have been offered a defibrillator if evaluated before their event. This casts doubt on the utility of the score model for primary prevention of sudden death. Inherent issues with modern risk scoring strategies decrease the likelihood of success even in robustly designed tools such as the Sieira score model.


Assuntos
Síndrome de Brugada/terapia , Morte Súbita Cardíaca/epidemiologia , Síndrome de Brugada/complicações , Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Medição de Risco , Síndrome do Nó Sinusal/fisiopatologia , Síncope/fisiopatologia , Reino Unido/epidemiologia
3.
Heart Rhythm ; 18(10): 1682-1690, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34004345

RESUMO

BACKGROUND: Conduction channels have been demonstrated within the postinfarct scar and seem to be co-located with the isthmus of ventricular tachycardia (VT). Mapping the local scar potentials (SPs) that define the conduction channels is often hindered by large far-field electrograms generated by healthy myocardium. OBJECTIVE: The purpose of this study was to map conduction channel using ripple mapping to categorize SPs temporally and anatomically. We tested the hypothesis that ablation of early SPs would eliminate the latest SPs without direct ablation. METHODS: Ripple maps of postinfarct scar were collected using the PentaRay (Biosense Webster) during normal rhythm. Maps were reviewed in reverse, and clusters of SPs were color-coded on the geometry, by timing, into early, intermediate, late, and terminal. Ablation was delivered sequentially from clusters of early SPs, checking for loss of terminal SPs as the endpoint. RESULTS: The protocol was performed in 11 patients. Mean mapping time was 65 ± 23 minutes, and a mean 3050 ± 1839 points was collected. SP timing ranged from 98.1 ± 60.5 ms to 214.8 ± 89.8 ms post QRS peak. Earliest SPs were present at the border, occupying 16.4% of scar, whereas latest SPs occupied 4.8% at the opposing border or core. Analysis took 15 ± 10 minutes to locate channels and identify ablation targets. It was possible to eliminate latest SPs in all patients without direct ablation (mean ablation time 16.3 ± 11.1 minutes). No VT recurrence was recorded (mean follow-up 10.1 ± 7.4 months). CONCLUSION: Conduction channels can be located using ripple mapping to analyze SPs. Ablation at channel entrances can eliminate the latest SPs and is associated with good medium-term results.


Assuntos
Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Infarto do Miocárdio/complicações , Miocárdio/patologia , Taquicardia Ventricular/etiologia , Idoso , Cicatriz/complicações , Cicatriz/diagnóstico , Cicatriz/fisiopatologia , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia
4.
J Am Heart Assoc ; 10(9): e020006, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33870715

RESUMO

Background Survivors of myocardial infarction are at increased risk of late ventricular arrhythmias, with infarct size and scar heterogeneity being key determinants of arrhythmic risk. Gap junctions facilitate the passage of small ions and morphogenic cell signaling between myocytes. We hypothesized that gap junctions enhancement during infarction-reperfusion modulates structural and electrophysiological remodeling and reduces late arrhythmogenesis. Methods and Results Infarction-reperfusion surgery was carried out in male Sprague-Dawley rats followed by 7 days of rotigaptide or saline administration. The in vivo and ex vivo arrhythmogenicity was characterized by programmed electrical stimulation 3 weeks later, followed by diffusion-weighted magnetic resonance imaging and Masson's trichrome histology. Three weeks after 7-day postinfarction administration of rotigaptide, ventricular tachycardia/ventricular fibrillation was induced on programmed electrical stimulation in 20% and 53% of rats, respectively (rotigaptide versus control), resulting in reduction of arrhythmia score (3.2 versus 1.4, P=0.018), associated with the reduced magnetic resonance imaging parameters fractional anisotropy (fractional anisotropy: -5% versus -15%; P=0.062) and mean diffusivity (mean diffusivity: 2% versus 6%, P=0.042), and remodeling of the 3-dimensional laminar structure of the infarct border zone with reduction of the mean (16° versus 19°, P=0.013) and the dispersion (9° versus 12°, P=0.015) of the myofiber transverse angle. There was no change in ECG features, spontaneous arrhythmias, or mortality. Conclusions Enhancement of gap junctions function by rotigaptide administered during the early healing phase in reperfused infarction reduces later complexity of infarct scar morphology and programmed electrical stimulation-induced arrhythmias, and merits further exploration as a feasible and practicable intervention in the acute myocardial infarction management to reduce late arrhythmic risk.


Assuntos
Arritmias Cardíacas/etiologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/tratamento farmacológico , Miocárdio/patologia , Oligopeptídeos/administração & dosagem , Remodelação Ventricular/fisiologia , Animais , Arritmias Cardíacas/fisiopatologia , Modelos Animais de Doenças , Progressão da Doença , Relação Dose-Resposta a Droga , Esquema de Medicação , Infusões Intravenosas , Masculino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Ratos , Ratos Sprague-Dawley , Índice de Gravidade de Doença , Fatores de Tempo
5.
Circ Arrhythm Electrophysiol ; 13(8): e007952, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32628863

RESUMO

Artificial intelligence (AI) and machine learning (ML) in medicine are currently areas of intense exploration, showing potential to automate human tasks and even perform tasks beyond human capabilities. Literacy and understanding of AI/ML methods are becoming increasingly important to researchers and clinicians. The first objective of this review is to provide the novice reader with literacy of AI/ML methods and provide a foundation for how one might conduct an ML study. We provide a technical overview of some of the most commonly used terms, techniques, and challenges in AI/ML studies, with reference to recent studies in cardiac electrophysiology to illustrate key points. The second objective of this review is to use examples from recent literature to discuss how AI and ML are changing clinical practice and research in cardiac electrophysiology, with emphasis on disease detection and diagnosis, prediction of patient outcomes, and novel characterization of disease. The final objective is to highlight important considerations and challenges for appropriate validation, adoption, and deployment of AI technologies into clinical practice.


Assuntos
Potenciais de Ação , Arritmias Cardíacas/diagnóstico , Inteligência Artificial , Diagnóstico por Computador , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Aprendizado de Máquina , Processamento de Sinais Assistido por Computador , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Aprendizado Profundo , Humanos , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes
7.
JACC Clin Electrophysiol ; 5(6): 705-715, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31221358

RESUMO

OBJECTIVES: This study sought to test specialized processing of laser Doppler signals for discriminating ventricular fibrillation (VF) from common causes of inappropriate therapies. BACKGROUND: Inappropriate implantable cardioverter-defibrillator (ICD) therapies remain a clinically important problem associated with morbidity and mortality. Tissue perfusion biomarkers, implemented to assist automated diagnosis of VF, sometimes mistake artifacts and random noise for perfusion, which could lead to shocks being inappropriately withheld. METHODS: The study tested a novel processing algorithm that combines electrogram data and laser Doppler perfusion monitoring as a method for assessing circulatory status. Fifty patients undergoing VF induction during ICD implantation were recruited. Noninvasive laser Doppler and continuous electrograms were recorded during both sinus rhythm and VF. Two additional scenarios that might have led to inappropriate shocks were simulated for each patient: ventricular lead fracture and T-wave oversensing. The laser Doppler was analyzed using 3 methods for reducing noise: 1) running mean; 2) oscillatory height; and 3) a novel quantification of electromechanical coupling which gates laser Doppler relative to electrograms. In addition, the algorithm was tested during exercise-induced sinus tachycardia. RESULTS: Only the electromechanical coupling algorithm found a clear perfusion cut off between sinus rhythm and VF (sensitivity and specificity of 100%). Sensitivity and specificity remained at 100% during simulated lead fracture and electrogram oversensing. (Area under the curve running mean: 0.91; oscillatory height: 0.86; electromechanical coupling: 1.00). Sinus tachycardia did not cause false positive results. CONCLUSIONS: Quantifying the coupling between electrical and perfusion signals increases reliability of discrimination between VF and artifacts that ICDs may interpret as VF. Incorporating such methods into future ICDs may safely permit reductions of inappropriate shocks.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Eletrocardiografia , Falha de Equipamento , Fluxometria por Laser-Doppler , Processamento de Sinais Assistido por Computador , Fibrilação Ventricular/diagnóstico , Idoso , Algoritmos , Técnicas Eletrofisiológicas Cardíacas , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Taquicardia Sinusal
8.
J Cardiovasc Electrophysiol ; 30(9): 1464-1474, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31211473

RESUMO

BACKGROUND: Conventional mapping techniques during atrial fibrillation (AF) are difficult to apply because of cycle length irregularity. Mapping studies are usually restricted to short durations of AF in limited regions because of the laborious manual annotation of local activation time (LAT). The purpose of this study was to test an automated algorithm to map activation during AF, with comparable accuracy to manual annotation. METHODS: Left atrial (LA) mapping was performed using a 20-pole double loop catheter (AFocusII) in 30-second data segments from 16 patients. The new algorithm (RETRO-Mapping) was designed to detect wavefront propagation between electrodes, and display activating wavefronts on a two-dimensional representation of the catheter. Activation patterns were validated against their bipolar electrograms and with isochronal maps. The mapping protocol was approved by the research ethics committee (13/LO1169 and 14/LO1367). RESULTS: During AF, uniform wavefront activation direction (mean ± SD, degrees) from manually constructed isochronal maps was comparable to RETRO-Propagation Map (RETRO-PM) and RETRO-Automated Direction (RETRO-AD): 1 ± 6.9 for RETRO-PM; and 2 ± 6.6 for RETRO-AD. There was no significant difference in activation direction assigned to 1373 uniform wavefronts during AF when comparing RETRO-PM with RETRO-AD (Bland-Altman mean difference: -0.1 degrees; limits of agreement: -8.0 to 8.3; 95% CI -0.4 to 0.2; (r = 0.01) R2 = < 0.005; P = .77). CONCLUSION: We have developed and validated a new technique to map activation during AF. This technique shows comparable accuracy to that of conventional isochronal mapping with careful manual adjustment of LAT.


Assuntos
Algoritmos , Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo , Cateteres Cardíacos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Átrios do Coração/fisiopatologia , Processamento de Sinais Assistido por Computador , Potenciais de Ação , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Automação , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo
9.
Heart Rhythm ; 16(9): 1357-1367, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31170484

RESUMO

BACKGROUND: Bipolar electrogram voltage during sinus rhythm (VSR) has been used as a surrogate for atrial fibrosis in guiding catheter ablation of persistent atrial fibrillation (AF), but the fixed rate and wavefront characteristics present during sinus rhythm may not accurately reflect underlying functional vulnerabilities responsible for AF maintenance. OBJECTIVE: The purpose of this study was determine whether, given adequate temporal sampling, the spatial distribution of mean AF voltage (VmAF) better correlates with delayed-enhancement magnetic resonance imaging (MRI-DE)-detected atrial fibrosis than VSR. METHODS: AF was mapped (8 seconds) during index ablation for persistent AF (20 patients) using a 20-pole catheter (660 ± 28 points/map). After cardioversion, VSR was mapped (557 ± 326 points/map). Electroanatomic and MRI-DE maps were co-registered in 14 patients. RESULTS: The time course of VmAF was assessed from 1-40 AF cycles (∼8 seconds) at 1113 locations. VmAF stabilized with sampling >4 seconds (mean voltage error 0.05 mV). Paired point analysis of VmAF from segments acquired 30 seconds apart (3667 sites; 15 patients) showed strong correlation (r = 0.95; P <.001). Delayed enhancement (DE) was assessed across the posterior left atrial (LA) wall, occupying 33% ± 13%. VmAF distributions were (median [IQR]) 0.21 [0.14-0.35] mV in DE vs 0.52 [0.34-0.77] mV in non-DE regions. VSR distributions were 1.34 [0.65-2.48] mV in DE vs 2.37 [1.27-3.97] mV in non-DE. VmAF threshold of 0.35 mV yielded sensitivity of 75% and specificity of 79% in detecting MRI-DE compared with 63% and 67%, respectively, for VSR (1.8-mV threshold). CONCLUSION: The correlation between low-voltage and posterior LA MRI-DE is significantly improved when acquired during AF vs sinus rhythm. With adequate sampling, mean AF voltage is a reproducible marker reflecting the functional response to the underlying persistent AF substrate.


Assuntos
Fibrilação Atrial , Técnicas Eletrofisiológicas Cardíacas/métodos , Átrios do Coração , Imagem Cinética por Ressonância Magnética/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Correlação de Dados , Feminino , Fibrose/complicações , Fibrose/diagnóstico , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
10.
Europace ; 21(8): 1176-1184, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31071213

RESUMO

AIMS: Ablation of persistent atrial fibrillation (PsAF) has been performed by many techniques with varying success rates. This may be due to ablation techniques, patient demographics, comorbidities, and trial design. We conducted a meta-regression of studies of PsAF ablation to elucidate the factors affecting atrial fibrillation (AF) recurrence. METHODS AND RESULTS: Databases were searched for prospective studies of PsAF ablation. A meta-regression was performed. Fifty-eight studies (6767 patients) were included. Complex fractionated atrial electrogram (CFAE) ablation reduced freedom from AF by 8.9% [95% confidence interval (CI) -15 to -2.3, P = 0.009). Left atrial appendage [LAA isolation (three study arms)] increased freedom from AF by 39.5% (95% CI 9.1-78.4, P = 0.008). Posterior wall isolation (PWI) (eight study arms) increased freedom from AF by 19.4% (95% CI 3.3-38.1, P = 0.017). Linear ablation or ganglionated plexi ablation resulted in no significant effect on freedom from AF. More extensive ablation increased intraprocedural AF termination; however, intraprocedural AF termination was not associated with improved outcomes. Increased left atrial diameter was associated with a reduction in freedom from AF by 4% (95% CI -6.8% to -1.1%, P = 0.007) for every 1 mm increase in diameter. CONCLUSION: Linear ablation, PWI, and CFAE ablation improves intraprocedural AF termination, but such termination does not predict better long-term outcomes. Study arms including PWI or LAA isolation in the lesion set were associated with improved outcomes in terms of freedom from AF; however, further randomized trials are required before these can be routinely recommended. Left atrial size is the most important marker of AF chronicity influencing outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Efeitos Adversos de Longa Duração/epidemiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Recidiva , Análise de Regressão , Medição de Risco/métodos , Resultado do Tratamento
11.
Comput Biol Med ; 104: 339-351, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30442428

RESUMO

We review some of the latest approaches to analysing cardiac electrophysiology data using machine learning and predictive modelling. Cardiac arrhythmias, particularly atrial fibrillation, are a major global healthcare challenge. Treatment is often through catheter ablation, which involves the targeted localised destruction of regions of the myocardium responsible for initiating or perpetuating the arrhythmia. Ablation targets are either anatomically defined, or identified based on their functional properties as determined through the analysis of contact intracardiac electrograms acquired with increasing spatial density by modern electroanatomic mapping systems. While numerous quantitative approaches have been investigated over the past decades for identifying these critical curative sites, few have provided a reliable and reproducible advance in success rates. Machine learning techniques, including recent deep-learning approaches, offer a potential route to gaining new insight from this wealth of highly complex spatio-temporal information that existing methods struggle to analyse. Coupled with predictive modelling, these techniques offer exciting opportunities to advance the field and produce more accurate diagnoses and robust personalised treatment. We outline some of these methods and illustrate their use in making predictions from the contact electrogram and augmenting predictive modelling tools, both by more rapidly predicting future states of the system and by inferring the parameters of these models from experimental observations.


Assuntos
Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Aprendizado de Máquina , Modelos Cardiovasculares , Fibrilação Atrial/cirurgia , Ablação por Cateter , Sistema de Condução Cardíaco/cirurgia , Humanos
12.
Comput Biol Med ; 102: 315-326, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30025847

RESUMO

Atrial and ventricular fibrillation are complex arrhythmias, and their underlying mechanisms remain widely debated and incompletely understood. This is partly because the electrical signals recorded during myocardial fibrillation are themselves complex and difficult to interpret with simple analytical tools. There are currently a number of analytical approaches to handle fibrillation data. Some of these techniques focus on mapping putative drivers of myocardial fibrillation, such as dominant frequency, organizational index, Shannon entropy and phase mapping. Other techniques focus on mapping the underlying myocardial substrate sustaining fibrillation, such as voltage mapping and complex fractionated electrogram mapping. In this review, we discuss these techniques, their application and their limitations, with reference to our experimental and clinical data. We also describe novel tools including a new algorithm to map microreentrant circuits sustaining fibrillation.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Eletrocardiografia , Coração/diagnóstico por imagem , Miocárdio/patologia , Fibrilação Ventricular/diagnóstico por imagem , Algoritmos , Animais , Linhagem Celular , Técnicas Eletrofisiológicas Cardíacas/métodos , Entropia , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Processamento de Sinais Assistido por Computador
13.
Circ Arrhythm Electrophysiol ; 11(6): e005846, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29884620

RESUMO

BACKGROUND: Mechanisms for persistent atrial fibrillation (AF) are unclear. We hypothesized that putative AF drivers and disorganized zones may interact dynamically over short time scales. We studied this interaction over prolonged durations, focusing on regions where ablation terminates persistent AF using 2 mapping methods. METHODS: We recruited 55 patients with persistent AF in whom ablation terminated AF prior to pulmonary vein isolation from a multicenter registry. AF was mapped globally using electrograms for 360±45 cycles using (1) a published phase method and (2) a commercial activation/phase method. RESULTS: Patients were 62.2±9.7 years, 76% male. Sites of AF termination showed rotational/focal patterns by methods 1 and 2 (51/55 vs 55/55; P=0.13) in spatially conserved regions, yet fluctuated over time. Time points with no AF driver showed competing drivers elsewhere or disordered waves. Organized regions were detected for 61.6±23.9% and 70.6±20.6% of 1 minute per method (P=nonsignificant), confirmed by automatic phase tracking (P<0.05). To detect AF drivers with >90% sensitivity, 8 to 32 s of AF recordings were required depending on driver definition. CONCLUSIONS: Sites at which persistent AF terminated by ablation show organized activation that fluctuate over time, because of collision from concurrent organized zones or fibrillatory waves, yet recur in conserved spatial regions. Results were similar by 2 mapping methods. This network of competing mechanisms should be reconciled with existing disorganized or driver mechanisms for AF, to improve clinical mapping and ablation of persistent AF. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02997254.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Alemanha , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
14.
J Cardiovasc Electrophysiol ; 29(3): 404-411, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29341322

RESUMO

BACKGROUND: Postablation reentrant ATs depend upon conducting isthmuses bordered by scar. Bipolar voltage maps highlight scar as sites of low voltage, but the voltage amplitude of an electrogram depends upon the myocardial activation sequence. Furthermore, a voltage threshold that defines atrial scar is unknown. We used Ripple Mapping (RM) to test whether these isthmuses were anatomically fixed between different activation vectors and atrial rates. METHODS: We studied post-AF ablation ATs where >1 rhythm was mapped. Multipolar catheters were used with CARTO Confidense for high-density mapping. RM visualized the pattern of activation, and the voltage threshold below which no activation was seen. Isthmuses were characterized at this threshold between maps for each patient. RESULTS: Ten patients were studied (Map 1 was AT1; Map 2: sinus 1/10, LA paced 2/10, AT2 with reverse CS activation 3/10; AT2 CL difference 50 ± 30 ms). Point density was similar between maps (Map 1: 2,589 ± 1,330; Map 2: 2,214 ± 1,384; P  =  0.31). RM activation threshold was 0.16 ± 0.08 mV. Thirty-one isthmuses were identified in Map 1 (median 3 per map; width 27 ± 15 mm; 7 anterior; 6 roof; 8 mitral; 9 septal; 1 posterior). Importantly, 7 of 31 (23%) isthmuses were unexpectedly identified within regions without prior ablation. AT1 was treated following ablation of 11/31 (35%) isthmuses. Of the remaining 20 isthmuses, 14 of 16 isthmuses (88%) were consistent between the two maps (four were inadequately mapped). Wavefront collision caused variation in low voltage distribution in 2 of 16 (12%). CONCLUSIONS: The distribution of isthmuses and nonconducting tissue within the ablated left atrium, as defined by RM, appear concordant between rhythms. This could guide a substrate ablative approach.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateteres Cardíacos , Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 29(1): 115-126, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091329

RESUMO

BACKGROUND: Models of cardiac arrhythmogenesis predict that nonuniformity in repolarization and/or depolarization promotes ventricular fibrillation and is modulated by autonomic tone, but this is difficult to evaluate in patients. We hypothesize that such spatial heterogeneities would be detected by noninvasive ECG imaging (ECGi) in sudden cardiac death (SCD) survivors with structurally normal hearts under physiological stress. METHODS: ECGi was applied to 11 SCD survivors, 10 low-risk Brugada syndrome patients (BrS), and 10 controls undergoing exercise treadmill testing. ECGi provides whole heart activation maps and >1,200 unipolar electrograms over the ventricular surface from which global dispersion of activation recovery interval (ARI) and regional delay in conduction were determined. These were used as surrogates for spatial heterogeneities in repolarization and depolarization. Surface ECG markers of dispersion (QT and Tpeak-end intervals) were also calculated for all patients for comparison. RESULTS: Following exertion, the SCD group demonstrated the largest increase in ARI dispersion compared to BrS and control groups (13 ± 8 ms vs. 4 ± 7 ms vs. 4 ± 5 ms; P = 0.009), with baseline dispersion being similar in all groups. In comparison, surface ECG markers of dispersion of repolarization were unable to discriminate between the groups at baseline or following exertion. Spatial heterogeneities in conduction were also present following exercise but were not significantly different between SCD survivors and the other groups. CONCLUSION: Increased dispersion of repolarization is apparent during physiological stress in SCD survivors and is detectable with ECGi but not with standard ECG parameters. The electrophysiological substrate revealed by ECGi could be the basis of alternative risk-stratification techniques.


Assuntos
Potenciais de Ação , Mapeamento Potencial de Superfície Corporal , Morte Súbita Cardíaca/etiologia , Teste de Esforço , Exercício Físico , Sistema de Condução Cardíaco/fisiopatologia , Estresse Fisiológico , Fibrilação Ventricular/diagnóstico , Adulto , Idoso , Morte Súbita Cardíaca/prevenção & controle , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Fibrilação Ventricular/complicações , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia
16.
Circ Arrhythm Electrophysiol ; 10(5): e004899, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28500175

RESUMO

BACKGROUND: Recent studies have demonstrated conflicting mechanisms underlying atrial fibrillation (AF), with the spatial resolution of data often cited as a potential reason for the disagreement. The purpose of this study was to investigate whether the variation in spatial resolution of mapping may lead to misinterpretation of the underlying mechanism in persistent AF. METHODS AND RESULTS: Simulations of rotors and focal sources were performed to estimate the minimum number of recording points required to correctly identify the underlying AF mechanism. The effects of different data types (action potentials and unipolar or bipolar electrograms) and rotor stability on resolution requirements were investigated. We also determined the ability of clinically used endocardial catheters to identify AF mechanisms using clinically recorded and simulated data. The spatial resolution required for correct identification of rotors and focal sources is a linear function of spatial wavelength (the distance between wavefronts) of the arrhythmia. Rotor localization errors are larger for electrogram data than for action potential data. Stationary rotors are more reliably identified compared with meandering trajectories, for any given spatial resolution. All clinical high-resolution multipolar catheters are of sufficient resolution to accurately detect and track rotors when placed over the rotor core although the low-resolution basket catheter is prone to false detections and may incorrectly identify rotors that are not present. CONCLUSIONS: The spatial resolution of AF data can significantly affect the interpretation of the underlying AF mechanism. Therefore, the interpretation of human AF data must be taken in the context of the spatial resolution of the recordings.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Eletrocardiografia/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Desenho de Equipamento , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo
17.
Europace ; 19(9): 1454-1462, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339601

RESUMO

AIMS: Initiating mechanisms of atrial fibrillation (AF) remain poorly understood, involving complex interaction between triggers and the atrial substrate. This study sought to classify the transitional phenomena, hypothesizing that there is consistency within and between patients in trigger-substrate interaction during transition to AF. METHODS AND RESULTS: Non-contact left atrial (LA) mapping was performed in 17 patients undergoing ablation for paroxysmal AF. All had spontaneous ectopy. Left atrial activation from the first ectopic to established AF was examined offline to characterize the initiating and transitional sequence of activation. In 57 fully mapped spontaneous AF initiations in 8 patients, all involved interaction of pulmonary venous/LA triggers with a septopulmonary line of block (SP-LOB) also evident in sinus rhythm, by 4 different transitional mechanisms characterized by (i) continuous focal firing: AF resulted from fragmentation of each ectopic wavefront through gaps in the SP-LOB and persisted only while focal firing continued (n = 18/32%) (ii) transient focal firing, wavefront fragmentation at the SP-LOB produced wavelet re-entry that persisted after cessation of an initiating ectopic source (n = 12/21%), (iii) of two separate interacting ectopic foci (n = 15/26%), or from (iv) transiently stable macroreentry (n = 12/21%), around the SP-LOB extending to the LA roof, resulting in progressive wavefront fragmentation. It was found that 79 ± 22% of each of the initiations in individual patients showed the same triggering mechanism. CONCLUSION: Onset of paroxysmal AF can be described by discrete mechanistic categories, all involving interaction of ectopic activity with a common SP-LOB. Within/between-patient consistency of initiations suggests constancy of the interacting triggers and substrate, and supports the concept of mechanistically tailored treatment.


Assuntos
Potenciais de Ação , Fibrilação Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
18.
Int J Cardiol ; 220: 580-8, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27390994

RESUMO

BACKGROUND: Post-operative atrial fibrillation (POAF) is a major health economic burden. However, the precise mechanisms in POAF remain unclear. In other forms of AF, sites of high dominant frequency (DF) in sinus rhythm (SR) may harbour 'AF nests'. We studied AF inducibility in relation to substrate changes using epicardial electrograms and cardiomyocyte calcium handling in the atria of AF naïve patients. METHOD: Bipolar electrograms were recorded from the lateral right atrial (RA) wall in 34 patients undergoing coronary surgery using a high-density array in sinus rhythm (NSR). RA burst pacing at 200/500/1000ms cycle lengths (CL) was performed, recording episodes of AF>30s. Co-localised RA tissue was snap frozen for RNA and protein extraction. RESULTS: Electrograms prolonged during AF (76.64±29.35ms) vs. NSR/pacing (p<0.001). Compared to NSR, electrogram amplitude was reduced during AF and during pacing at 200ms CL (p<0.001). Electrogram DF was significantly lower in AF (75.87±23.63Hz) vs. NSR (89.33±25.99Hz) (p<0.05), and NSR DF higher in AF inducible patients at the site of AF initiation (p<0.05). Structurally, POAF atrial myocardium demonstrated reduced sarcolipin gene (p=0.0080) and protein (p=0.0242) expression vs. NSR. Phospholamban gene and protein expression was unchanged. SERCA2a protein expression remained unchanged, but MYH6 (p=0.0297) and SERCA2A (p=0.0343) gene expression was reduced in POAF. CONCLUSIONS: Human atrial electrograms prolong and reduce in amplitude in induced peri-operative AF vs. NSR or pacing. In those sustaining AF, high DF sites in NSR may indicate 'AF nests'. This electrical remodelling is accompanied by structural remodelling with altered expression of cardiomyocyte calcium handling detectable before POAF. These novel upstream substrate changes offer a novel mechanism and manifestation of human POAF.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Átrios do Coração/fisiopatologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Idoso , Função do Átrio Direito/fisiologia , Estudos de Coortes , Feminino , Átrios do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
19.
Artigo em Inglês | MEDLINE | ID: mdl-27307519

RESUMO

BACKGROUND: Post-infarct ventricular tachycardia is associated with channels of surviving myocardium within scar characterized by fractionated and low-amplitude signals usually occurring late during sinus rhythm. Conventional automated algorithms for 3-dimensional electro-anatomic mapping cannot differentiate the delayed local signal of conduction within the scar from the initial far-field signal generated by surrounding healthy tissue. Ripple mapping displays every deflection of an electrogram, thereby providing fully informative activation sequences. We prospectively used CARTO-based ripple maps to identify conducting channels as a target for ablation. METHODS AND RESULTS: High-density bipolar left ventricular endocardial electrograms were collected using CARTO3v4 in sinus rhythm or ventricular pacing and reviewed for ripple mapping conducting channel identification. Fifteen consecutive patients (median age 68 years, left ventricular ejection fraction 30%) were studied (6 month preprocedural implantable cardioverter defibrillator therapies: median 19 ATP events [Q1-Q3=4-93] and 1 shock [Q1-Q3=0-3]). Scar (<1.5 mV) occupied a median 29% of the total surface area (median 540 points collected within scar). A median of 2 ripple mapping conducting channels were seen within each scar (length 60 mm; initial component 0.44 mV; delayed component 0.20 mV; conduction 55 cm/s). Ablation was performed along all identified ripple mapping conducting channels (median 18 lesions) and any presumed interconnected late-activating sites (median 6 lesions; Q1-Q3=2-12). The diastolic isthmus in ventricular tachycardia was mapped in 3 patients and colocated within the ripple mapping conducting channels identified. Ventricular tachycardia was noninducible in 85% of patients post ablation, and 71% remain free of ventricular tachycardia recurrence at 6-month median follow-up. CONCLUSIONS: Ripple mapping can be used to identify conduction channels within scar to guide functional substrate ablation.


Assuntos
Cicatriz/patologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Infarto do Miocárdio/patologia , Taquicardia Ventricular/patologia , Idoso , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Masculino , Infarto do Miocárdio/complicações , Estudos Prospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
20.
Circ Arrhythm Electrophysiol ; 9(1): e003582, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26757985

RESUMO

BACKGROUND: Post ablation atrial tachycardias are characterized by low-voltage signals that challenge current mapping methods. Ripple mapping (RM) displays every electrogram deflection as a bar moving from the cardiac surface, resulting in the impression of propagating wavefronts when a series of bars move consecutively. RM displays fractionated signals in their entirety thereby helping to identify propagating activation in low-voltage areas from nonconducting tissue. We prospectively used RM to study tachycardia activation in the previously ablated left atrium. METHODS AND RESULTS: Patients referred for atrial tachycardia ablation underwent dense electroanatomic point collection using CARTO3v4. RM was played over a bipolar voltage map and used to determine the voltage "activation threshold" that differentiated functional low voltage from nonconducting areas for each map. Ablation was guided by RM, but operators could perform entrainment or review the isochronal activation map for diagnostic uncertainty. Twenty patients were studied. Median RM determined activation threshold was 0.3 mV (0.19-0.33), with nonconducting tissue covering 33±9% of the mapped surface. All tachycardias crossed an isthmus (median, 0.52 mV, 13 mm) bordered by nonconducting tissue (70%) or had a breakout source (median, 0.35 mV) moving away from nonconducting tissue (30%). In reentrant circuits (14/20) the path length was measured (87-202 mm), with 9 of 14 also supporting a bystander circuit (path lengths, 147-234 mm). In breakout tachycardias, splitting of wavefronts resulted in 2 to 4 incomplete circuits. RM-guided ablation interrupted the tachycardia in 19 of 20 cases with the first ablation set. CONCLUSIONS: RM helps to define activation through low-voltage regions and aids ablation of atrial tachycardias.


Assuntos
Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia Atrial Ectópica/diagnóstico , Adulto , Idoso , Diagnóstico Diferencial , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Atrial Ectópica/fisiopatologia , Taquicardia Atrial Ectópica/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA