Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
N Engl J Med ; 384(18): 1705-1718, 2021 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-33951360

RESUMO

BACKGROUND: Rifapentine-based regimens have potent antimycobacterial activity that may allow for a shorter course in patients with drug-susceptible pulmonary tuberculosis. METHODS: In an open-label, phase 3, randomized, controlled trial involving persons with newly diagnosed pulmonary tuberculosis from 13 countries, we compared two 4-month rifapentine-based regimens with a standard 6-month regimen consisting of rifampin, isoniazid, pyrazinamide, and ethambutol (control) using a noninferiority margin of 6.6 percentage points. In one 4-month regimen, rifampin was replaced with rifapentine; in the other, rifampin was replaced with rifapentine and ethambutol with moxifloxacin. The primary efficacy outcome was survival free of tuberculosis at 12 months. RESULTS: Among 2516 participants who had undergone randomization, 2343 had a culture positive for Mycobacterium tuberculosis that was not resistant to isoniazid, rifampin, or fluoroquinolones (microbiologically eligible population; 768 in the control group, 791 in the rifapentine-moxifloxacin group, and 784 in the rifapentine group), of whom 194 were coinfected with human immunodeficiency virus and 1703 had cavitation on chest radiography. A total of 2234 participants could be assessed for the primary outcome (assessable population; 726 in the control group, 756 in the rifapentine-moxifloxacin group, and 752 in the rifapentine group). Rifapentine with moxifloxacin was noninferior to the control in the microbiologically eligible population (15.5% vs. 14.6% had an unfavorable outcome; difference, 1.0 percentage point; 95% confidence interval [CI], -2.6 to 4.5) and in the assessable population (11.6% vs. 9.6%; difference, 2.0 percentage points; 95% CI, -1.1 to 5.1). Noninferiority was shown in the secondary and sensitivity analyses. Rifapentine without moxifloxacin was not shown to be noninferior to the control in either population (17.7% vs. 14.6% with an unfavorable outcome in the microbiologically eligible population; difference, 3.0 percentage points [95% CI, -0.6 to 6.6]; and 14.2% vs. 9.6% in the assessable population; difference, 4.4 percentage points [95% CI, 1.2 to 7.7]). Adverse events of grade 3 or higher occurred during the on-treatment period in 19.3% of participants in the control group, 18.8% in the rifapentine-moxifloxacin group, and 14.3% in the rifapentine group. CONCLUSIONS: The efficacy of a 4-month rifapentine-based regimen containing moxifloxacin was noninferior to the standard 6-month regimen in the treatment of tuberculosis. (Funded by the Centers for Disease Control and Prevention and others; Study 31/A5349 ClinicalTrials.gov number, NCT02410772.).


Assuntos
Antibióticos Antituberculose/administração & dosagem , Antituberculosos/uso terapêutico , Moxifloxacina/administração & dosagem , Mycobacterium tuberculosis/isolamento & purificação , Rifampina/administração & dosagem , Tuberculose Pulmonar/tratamento farmacológico , Adolescente , Adulto , Antibióticos Antituberculose/efeitos adversos , Antituberculosos/efeitos adversos , Criança , Intervalos de Confiança , Esquema de Medicação , Quimioterapia Combinada , Feminino , Humanos , Masculino , Moxifloxacina/efeitos adversos , Rifampina/efeitos adversos , Adulto Jovem
2.
Thyroid ; 23(8): 1003-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23517405

RESUMO

BACKGROUND: Surgery and high-dose radioactive iodine ((131)I) treatment are the cornerstones in the treatment of differentiated thyroid cancer. Patients without (131)I uptake on the post-therapeutic whole body scan (WBS), but with detectable thyroglobulin (Tg) during thyroxine withdrawal (Tg-off), are evaluated with an 18-fluorodeoxyglucose positron emission tomography ((18)F-FDG-PET) for tumor localization within three months. The yield of (18)F-FDG-PET imaging and clinical usefulness of a Tg-off cutoff value to predict a positive scan were assessed. METHODS: From 2002 to 2011, 52 patients with a negative WBS and concurrent detectable Tg-off were evaluated. Thirty-five PET scans were performed during initial treatment, 17 after recurrent disease. Thirty-two patients were on substitution therapy, 17 were evaluated with endogenous thyrotropin elevation, and 3 after recombinant human thyrotropin stimulation. To determine the Tg-off cutoff value, a receiver operating characteristic curve was used. RESULTS: Nine (17%) (18)F-FDG-PET scans were true positive, 3 (6%) false positive, 36 (69%) true negative, and 4 (8%) false negative (sensitivity 69%, specificity 92%). In 13%, a true-positive scan resulted in a change in the clinical management. The area under the receiver operating characteristic curve is 0.82 [CI 0.64-0.99] (p<0.01), and the Tg-off cutoff value is 38.00 ng/mL (sensitivity 67%, specificity 95%). Ninety percent of (18)F-FDG-PET true-positive patients had a Tg-off >2.00 ng/mL. CONCLUSIONS: An (18)F-FDG-PET within three months after a negative WBS with detectable Tg-off showed additional tumor localization in 17% of the patients, leading to a change in clinical management in 13%. A clinically useful Tg-off cutoff value was not found, but 90% of positive (18)F-FDG-PET scans occurred in patients with a Tg-off >2.00 ng/mL.


Assuntos
Fluordesoxiglucose F18 , Tireoglobulina/sangue , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Radioisótopos do Iodo/uso terapêutico , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Neoplasias da Glândula Tireoide/patologia , Tireotropina
3.
Eur J Nucl Med Mol Imaging ; 35(5): 958-65, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18175115

RESUMO

BACKGROUND: The purpose of this prospective study was to evaluate the clinical diagnostic value of iodine-124 (124I)-positron emission tomography (PET) in patients with advanced differentiated thyroid carcinoma (DTC) and to compare the 124I-PET imaging results with the 131I whole-body scan (WBS). MATERIALS AND METHODS: Twenty patients with histologically proven advanced DTC (including T4, extra-nodal tumour growth, or distant metastases) underwent diagnostic 131I-WBS, 124I-PET scan, and post-treatment 131I-WBS 4 months after ablation. The findings on the 124I-PET were compared with the findings on the diagnostic and post-therapeutic 131I-WBS and were also correlated with radiologic and/or cytological investigations. RESULTS: 124 I-PET vs diagnostic 131 I-WBS. Eleven patients showed uptake on the 124I-PET. Only 3 of these 11 patients also showed uptake on the diagnostic 131I scan, but the uptake was more clearly visible and the abnormalities were more extensive on the 124I-PET. 124 I-PET vs post-treatment 131 I-WBS. Eleven patients showed uptake on the 124I-PET, which was also visible on the post-treatment scan in nine patients; in the other two patients, no uptake was observed on the post-treatment scan and no anatomical localisation could be confirmed. Two patients showed only uptake on the post-treatment scan without uptake on the 124I-PET: in one, the uptake was confirmed by MRI, and in the other, no anatomical localisation was found. In seven patients, no uptake was observed on both the scans. CONCLUSION: 124I-PET proved to be a superior diagnostic tool as compared to low-dose diagnostic 131I scans and adequately predicted findings on subsequent high-dose post-treatment 131I scans.


Assuntos
Radioisótopos do Iodo , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Cancer ; 103(1): 59-67, 2005 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-15565567

RESUMO

BACKGROUND: Findings of mediastinal uptake of 131I after surgical treatment for differentiated thyroid carcinoma (DTC) are common, especially in young patients. Given the frequency of false-positive findings, a protocol for diagnostic and therapeutic strategies would be useful. With the goal of accurately selecting management strategies, the authors analyzed their data and data found elsewhere in the literature for correlations with the incidence of mediastinal 131I uptake and with treatment for patients exhibiting such 131I uptake. METHODS: All patients with DTC who were treated between 1978 and 2000 at Groningen University Hospital (Groningen, The Netherlands) and who received adjuvant 131I ablation therapy were included in the current analysis, which involved retrospective review of all relevant data. RESULTS: Five hundred four patients with DTC initially underwent total thyroidectomy, with additional 131I ablation performed for 489 of these patients. In 48 of 489 patients (9.8%), 131I uptake was seen in the mediastinum on a posttreatment scan. Analysis of those 48 patients and of cases in the literature demonstrated that serum thyroglobulin levels, risk status, and the presence of thymus on radiologic images were important in the surgical decision-making process. CONCLUSIONS: Mediastinal uptake of 131I on posttreatment scans was found in approximately 10% of patients after total thyroidectomy for DTC. Based on the current data and the data presented in the literature, the authors developed a flow chart for determining appropriate treatment strategies, which included mediastinal dissection for high-risk patients and for patients with serum thyroglobulin levels > 10 ng/mL.


Assuntos
Carcinoma/diagnóstico por imagem , Carcinoma/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia , Adulto , Tomada de Decisões , Reações Falso-Positivas , Feminino , Humanos , Radioisótopos do Iodo/farmacocinética , Masculino , Mediastino/cirurgia , Pessoa de Meia-Idade , Planejamento de Assistência ao Paciente , Cintilografia , Estudos Retrospectivos , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA