RESUMO
BACKGROUND: The increasing incidence of healthcare-associated infections (HAIs) and multidrug-resistant organisms demonstrate the need for innovative technological solutions. Staphylococcus aureus, Streptococcus pneumonia, Escherichia coli, and Pseudomonas aeruginosa in particular are common pathogens responsible for a large percentage of indwelling medical device-associated clinical infections. The bactericidal effects of visible light sterilization (VLS) using 405-nm is one potential therapeutic under investigation. MATERIALS AND METHODS: Light-emitting diodes of 405-nm were used to treat varying concentrations of S aureus, S pneumonia, E coli, and P aeruginosa. Irradiance levels between 2.71 ± 0.20 to 9.27 ± 0.36 mW/cm2 and radiant exposure levels up to 132.98 ± 6.68 J/cm2 were assessed. RESULTS: Dose-dependent effects were observed in all species. Statistically significant reductions were seen in both Gram-positive and Gram-negative bacteria. At the highest radiant exposure levels, bacterial log10 reductions were E coli-6.27 ± 0.54, S aureus-6.10 ± 0.60, P aeruginosa-5.20 ± 0.84, and S pneumoniae-6.01 ± 0.59. Statistically significant results (<0.001*) were found at each time point. CONCLUSIONS: We have successfully demonstrated high-efficacy bacterial reduction using 405-nm light sterilization. The VLS showed statistical significance against both Gram-positive and Gram-negative species with the given treatment times. The ß-lactam antibiotic-resistant E coli was the most sensitive to VLS, suggesting light therapy could a suitable option for sterilization in drug-resistant bacterial species. This research illustrates the potential of using VLS in treating clinically relevant bacterial infections.
Assuntos
Infecção Hospitalar/prevenção & controle , Escherichia coli/efeitos da radiação , Luz , Pseudomonas aeruginosa/efeitos da radiação , Staphylococcus aureus/efeitos da radiação , Esterilização/métodos , Streptococcus pneumoniae/efeitos da radiação , HumanosRESUMO
BACKGROUND AND OBJECTIVE: Approximately 1.7 million patients are affected by hospital-acquired infections every year in the United States. The increasing prevalence of multidrug-resistant bacteria associated with these infections prompts the investigation of alternative sterilization and antibacterial therapies. One method currently under investigation is the antibacterial properties of visible light. This study examines the effect of a visible light therapy (VLT) on ß-lactam-resistant Escherichia coli, a common non-skin flora pathogen responsible for a large percentage of indwelling medical device-associated clinical infection. MATERIALS AND METHODS: 405 nm light-emitting diodes were used to treat varying concentrations of a common laboratory E. coli K-12 strain transformed with the pCIG mammalian expression vector. This conferred ampicillin resistance via expression of the ß-lactamase gene. Bacteria were grown on sterile polystyrene Petri dishes plated with Luria-Bertani broth. Images of bacterial growth colonies on plates were processed and analyzed using ImageJ. Irradiance levels between 2.89 ± 0.19 and 9.45 ± 0.63 mW cm(-2) and radiant exposure levels between 5.60 ± 0.39 and 136.91 ± 4.06 J cm(-2) were tested. RESULTS: VLT with variable irradiance and constant treatment time (120 minutes) demonstrated significant reduction (P < 0.001) in E. coli between an irradiance of 2.89 mW cm(-2) (81.70%) and 9.37 mW cm(-2) (100.00%). Similar results were found with variable treatment time with constant irradiance. Log10 reduction analysis produced between 1.98 ± 0.53 (60 minute treatment) and 6.27 ± 0.54 (250 minute treatment) log10 reduction in bacterial concentration (P < 0.001). CONCLUSIONS: We have successfully demonstrated a significant bacterial reduction using high intensity 405 nm light. Illustrating the efficacy of this technology against a ß-lactam-resistant E. coli is especially relevant to the need for novel methods of sterilization in healthcare settings. These results suggest that VLT using 405 nm light could be a suitable clinical option for eradication of ß-lactam-resistant E. coli. Visible light kills statistically significant concentrations of E. coli. Antibiotic-resistant Gram-negative bacteria exhibits sensitivity to 405 nm light. Greater than 6 log10 reduction in ß-lactam-resistant E. coli when treated with visible light therapy.