AIMS: The aim of this study was to investigate the influence of the activation sequence on voltage amplitudes by evaluating regional voltage differences during a left bundle branch block (LBBB) activation sequence vs. a normal synchronous activation sequence and by evaluating pacing-induced voltage differences. METHODS AND RESULTS: Twenty-one patients and three computer models without scar were studied. Regional voltage amplitudes were evaluated in nine LBBB patients who underwent endocardial electro-anatomic mapping (EAM). Pacing-induced voltage differences were evaluated in 12 patients who underwent epicardial EAM during intrinsic rhythm and right ventricular (RV) pacing. Three computer models customized for LBBB patients were created. Changes in voltage amplitudes after an LBBB (intrinsic), a normal synchronous, an RV pacing, and a left ventricular pacing activation sequence were assessed in the computer models. Unipolar voltage amplitudes in patients were approximately 4.5 mV (4.4-4.7 mV, ∼33%) lower in the septum when compared with other segments. A normal synchronous activation sequence in the computer models normalized voltage amplitudes in the septum. Pacing-induced differences were larger in electrograms with higher voltage amplitudes during intrinsic rhythm and furthermore larger and more variable at the epicardium [mean absolute difference: 3.6-6.2 mV, 40-53% of intrinsic value; interquartile range (IQR) differences: 53-63% of intrinsic value] compared to the endocardium (mean absolute difference: 3.3-3.8 mV, 28-30% of intrinsic value; IQR differences: 37-40% of intrinsic value). CONCLUSION: In patients and computer models without scar, lower septal unipolar voltage amplitudes are exclusively associated with an LBBB activation sequence. Pacing substantially affects voltage amplitudes, particularly at the epicardium.


Assuntos
Potenciais de Ação , Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Simulação por Computador , Frequência Cardíaca , Modelos Cardiovasculares , Adulto , Idoso , Idoso de 80 Anos ou mais , Fascículo Atrioventricular/diagnóstico por imagem , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular Direita
2.
JACC Clin Electrophysiol ; 4(1): 138-146, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29600778

RESUMO

OBJECTIVES: This study sought to test the accuracy of strain measurements based on anatomo-electromechanical mapping (AEMM) measurements compared with magnetic resonance imaging (MRI) tagging, to evaluate the diagnostic value of AEMM-based strain measurements in the assessment of myocardial viability, and the additional value of AEMM over peak-to-peak local voltages. BACKGROUND: The in vivo identification of viable tissue, evaluation of mechanical contraction, and simultaneous left ventricular activation is currently achieved using multiple complementary techniques. METHODS: In 33 patients, AEMM maps (NOGA XP, Biologic Delivery Systems, Division of Biosense Webster, a Johnson & Johnson Company, Irwindale, California) and MRI images (Siemens 3T, Siemens Healthcare, Erlangen, Germany) were obtained within 1 month. MRI tagging was used to determine circumferential strain (Ecc) and delayed enhancement to obtain local scar extent (%). Custom software was used to measure Ecc and local area strain (LAS) from the motion field of the AEMM catheter tip. RESULTS: Intertechnique agreement for Ecc was good (R2 = 0.80), with nonsignificant bias (0.01 strain units) and narrow limits of agreement (-0.03 to 0.06). Scar segments showed lower absolute strain amplitudes compared with nonscar segments: Ecc (median [first to third quartile]: nonscar -0.10 [-0.15 to -0.06] vs. scar -0.04 [-0.06 to -0.02]) and LAS (-0.20 [-0.27 to -0.14] vs. -0.09 [-0.14 to -0.06]). AEMM strains accurately discriminated between scar and nonscar segments, in particular LAS (area under the curve: 0.84, accuracy = 0.76), which was superior to peak-to-peak voltages (nonscar 9.5 [6.5 to 13.3] mV vs. scar 5.6 [3.4 to 8.3] mV; area under the curve: 0.75). Combination of LAS and peak-to-peak voltages resulted in 86% accuracy. CONCLUSIONS: An integrated AEMM approach can accurately determine local deformation and correlates with the scar extent. This approach has potential immediate application in the diagnosis, delivery of intracardiac therapies, and their intraprocedural evaluation.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Ablação por Cateter , Insuficiência Cardíaca , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Terapia Biológica , Feminino , Coração/diagnóstico por imagem , Coração/fisiopatologia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
3.
J Interv Card Electrophysiol ; 51(3): 205-214, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29388068

RESUMO

PURPOSE: Cardiac disease frequently has a degenerative effect on cardiac pump function and regional myocardial contraction. Therefore, an accurate assessment of regional wall motion is a measure of the extent and severity of the disease. We sought to further validate an intra-operative, sensor-based technology for measuring wall motion and strain by characterizing left ventricular (LV) mechanical and electrical activation patterns in patients with normal (NSF) and impaired systolic function (ISF). METHODS: NSF (n = 10; ejection fraction = 62.9 ± 6.1%) and ISF (n = 18; ejection fraction = 35.1 ± 13.6%) patients underwent simultaneous electrical and motion mapping of the LV endocardium using electroanatomical mapping and navigational systems (EnSite™ NavX™ and MediGuide™, Abbott). Motion trajectories, strain profiles, and activation times were calculated over the six standard LV walls. RESULTS: NSF patients had significantly greater motion and systolic strains across all LV walls than ISF patients. LV walls with low-voltage areas showed less motion and systolic strain than walls with normal voltage. LV electrical dyssynchrony was significantly smaller in NSF and ISF patients with narrow-QRS complexes than ISF patients with wide-QRS complexes, but mechanical dyssynchrony was larger in all ISF patients than NSF patients. The latest mechanical activation was most often the lateral/posterior walls in NSF and wide-QRS ISF patients but varied in narrow-QRS ISF patients. CONCLUSIONS: This intra-operative technique can be used to characterize LV wall motion and strain in patients with impaired systolic function. This technique may be utilized clinically to provide individually tailored LV lead positioning at the region of latest mechanical activation for patients undergoing cardiac resynchronization therapy. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01629160.


Assuntos
Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Mapeamento Epicárdico/métodos , Interpretação de Imagem Assistida por Computador , Volume Sistólico/fisiologia , Idoso , Fibrilação Atrial/diagnóstico , Terapia de Ressincronização Cardíaca/métodos , Ablação por Cateter/métodos , Eletrocardiografia Ambulatorial/métodos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Contração Miocárdica/fisiologia , Seleção de Pacientes , Recuperação de Função Fisiológica , Valores de Referência , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
4.
Europace ; 20(7): 1146-1153, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-29106563

RESUMO

Aims: Left ventricular (LV) fusion pacing appears to be at least as beneficial as biventricular pacing in cardiac resynchronization therapy (CRT). Optimal LV fusion pacing critically requires adjusting the atrioventricular (AV)-delay to the delay between atrial pacing and intrinsic right ventricular (RV) activation (Ap-RV). We explored the use of electrogram (EGM)-based vectorloop (EGMV) derived from EGMs of implanted pacing leads to achieve optimal LV fusion pacing and to compare it with conventional approaches. Methods and results: During CRT-device implantation, 28 patients were prospectively studied. During atrial-LV pacing (Ap-LVp) at various AV-delays, LV dP/dtmax, 12-lead electrocardiogram (ECG), and unipolar EGMs were recorded. Electrocardiogram and electrogram were used to reconstruct a vectorcardiogram (VCG) and EGMV, respectively, from which the maximum QRS amplitude (QRSampl), was extracted. Ap-RV was determined: (i) conventionally as the longest AV-delay at which QRS morphology was visually unaltered during RV pacing at increasing AV-delays(Ap-RVvis; reference-method); (ii) 70% of delay between atrial pacing and RV sensing (Ap-RVaCRT); and (iii) the delay between atrial pacing and onset of QRS (Ap-QRSonset). In both the EGMV and VCG, the longest AV-delay showing an unaltered QRSampl as compared with Ap-LVp with a short AV-delay, corresponded to Ap-RVvis. In contrast, Ap-QRSonset and Ap-RVaCRT were larger. The Ap-LVp induced increase in LV dP/dtmax was larger at Ap-RVvis, Ap-RVEGMV, and Ap-RVVCG than at Ap-QRSonset (all P < 0.05) and Ap-RVaCRT (P = 0.02, P = 0.13, and P = 0.03, respectively). Conclusion: In this acute study, it is shown that the EGMV QRSampl can be used to determine optimal and individual CRT-device settings for LV fusion pacing, possibly improving long-term CRT response.


Assuntos
Bloqueio de Ramo/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/terapia , Potenciais de Ação , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Tomada de Decisão Clínica , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Valor Preditivo dos Testes , Estudos Prospectivos , Processamento de Sinais Assistido por Computador , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Vetorcardiografia , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
5.
J Cardiovasc Electrophysiol ; 28(8): 944-951, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28467647

RESUMO

INTRODUCTION: Proper optimization of atrioventricular (AV) and interventricular (VV) intervals can improve the response to cardiac resynchronization therapy (CRT). It has been demonstrated that the area of the QRS complex (QRSarea) extracted from the vectorcardiogram can be used as a predictor of optimal CRT-device settings. We explored the possibility of extracting vectors from the electrograms (EGMs) obtained from pacing electrodes and of using these EGM-based vectors (EGMVs) to individually optimize acute hemodynamic CRT response. METHODS AND RESULTS: Biventricular pacing was performed in 13 dogs with left bundle branch block (LBBB) of which five also had myocardial infarction (MI), using 100 randomized AV- and VV-settings. Settings providing an acute increase in LV dP/dtmax ≥ 90% of the highest achieved value were defined as optimal. The prediction capability of QRSarea derived from the EGMV (EGMV-QRSarea) was compared with that of QRS duration. EGMV-QRSarea strongly correlated to the change in LV dP/dtmax (R = -0.73 ± 0.19 [LBBB] and -0.66 ± 0.14 [LBBB + MI]), while QRS duration was more poorly related to LV dP/dtmax changes (R = -0.33 ± 0.25 [LBBB] and -0.47 ± 0.39 [LBBB + MI]). This resulted in a better prediction of optimal CRT-device settings by EGMV-QRSarea than by QRS duration (LBBB: AUC = 0.89 [0.86-0.93] vs. 0.76 [0.69-0.83], P < 0.01; LBBB + MI: AUC = 0.91 [0.84-0.99] vs. 0.82 [0.59-1.00], P = 0.20, respectively). CONCLUSION: In canine hearts with chronic LBBB with or without MI, the EGMV-QRSarea predicts acute hemodynamic CRT response and identifies optimal AV and VV settings accurately. These data support the potency of EGM-based vectors as a noninvasive, easy and patient-tailored tool to optimize CRT-device settings.


Assuntos
Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Frequência Cardíaca/fisiologia , Animais , Cães , Feminino , Previsões , Masculino
7.
Europace ; 19(10): 1700-1709, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27738070

RESUMO

AIMS: In times of evolving cardiac resynchronization therapy, intra-procedural characterization of left ventricular (LV) mechanical activation patterns is desired but technically challenging with currently available technologies. In patients with normal systolic function, we evaluated the feasibility of characterizing LV wall motion using a novel sensor-based, real-time tracking technology. METHODS AND RESULTS: Ten patients underwent simultaneous motion and electrical mapping of the LV endocardium during sinus rhythm using electroanatomical mapping and navigational systems (EnSite™ NavX™ and MediGuide™, SJM). Epicardial motion data were also collected simultaneously at corresponding locations from accessible coronary sinus branches. Displacements at each mapping point and times of electrical and mechanical activation were combined over each of the six standard LV wall segments. Mechanical activation timing was compared with that from electrical activation and preoperative 2D speckle tracking echocardiography (echo). MediGuide-based displacement data were further analysed to estimate LV chamber volumes that were compared with echo and magnetic resonance imaging (MRI). The lateral and septal walls exhibited the largest (12.5 [11.6-15.0] mm) and smallest (10.2 [9.0-11.3] mm) displacement, respectively. Radial displacement was significantly larger endocardially than epicardially (endo: 6.7 [5.0-9.1] mm; epi: 3.8 [2.4-5.6] mm), while longitudinal displacement was significantly larger epicardially (endo: 8.0 [5.0-10.6] mm; epi: 10.3 [7.4-13.8] mm). Most often, the anteroseptal/anterior and lateral walls showed the earliest and latest mechanical activations, respectively. 9/10 patients had concordant or adjacent wall segments of latest mechanical and electrical activation, and 6/10 patients had concordant or adjacent wall segments of latest mechanical activation as measured by MediGuide and echo. MediGuide's LV chamber volumes were significantly correlated with MRI (R2= 0.73, P < 0.01) and echo (R2= 0.75, P < 0.001). CONCLUSION: The feasibility of mapping-guided intra-procedural characterization of LV wall motion was established. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov; Unique identifier: CT01629160.


Assuntos
Potenciais de Ação , Fenômenos Eletromagnéticos , Monitorização Ambulatorial/instrumentação , Telemetria/instrumentação , Transdutores , Função Ventricular Esquerda , Idoso , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/métodos , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Volume Sistólico , Sístole , Telemetria/métodos , Fatores de Tempo
8.
Europace ; 18(suppl 4): iv94-iv103, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28011836

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) produces clinical benefits in chronic heart failure patients with left bundle-branch block (LBBB). The position of the pacing site on the left ventricle (LV) is considered an important determinant of CRT response, but the mechanism how the LV pacing site determines CRT response is not completely understood. The objective of this study is to investigate the relation between LV pacing site during biventricular (BiV) pacing and cardiac function. METHODS AND RESULTS: We used a finite element model of BiV electromechanics. Cardiac function, assessed as LV dp/dtmax and stroke work, was evaluated during normal electrical activation, typical LBBB, fascicular blocks and BiV pacing with different LV pacing sites. The model replicated clinical observations such as increase of LV dp/dtmax and stroke work, and the disappearance of a septal flash during BiV pacing. The largest hemodynamic response was achieved when BiV pacing led to best resynchronization of LV electrical activation but this did not coincide with reduction in total BiV activation time (∼ QRS duration). Maximum response was achieved when pacing the mid-basal lateral wall and this was close to the latest activated region during intrinsic activation in the typical LBBB, but not in the fascicular block simulations. CONCLUSIONS: In these model simulations, the best cardiac function was obtained when pacing the mid-basal LV lateral wall, because of fastest recruitment of LV activation. This study illustrates how computer modeling can shed new light on optimizing pacing therapies for CRT. The results from this study may help to design new clinical studies to further investigate the importance of the pacing site for CRT response.


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Função Ventricular Esquerda , Potenciais de Ação , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca , Técnicas Eletrofisiológicas Cardíacas , Análise de Elementos Finitos , Frequência Cardíaca , Humanos , Análise Numérica Assistida por Computador , Valor Preditivo dos Testes , Processamento de Sinais Assistido por Computador , Volume Sistólico , Resultado do Tratamento , Pressão Ventricular
9.
J Cardiovasc Transl Res ; 9(4): 257-65, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27230674

RESUMO

Cardiac resynchronization therapy (CRT) is a well-known treatment modality for patients with a reduced left ventricular ejection fraction accompanied by a ventricular conduction delay. However, a large proportion of patients does not benefit from this therapy. Better patient selection may importantly reduce the number of non-responders. Here, we review the strengths and weaknesses of the electrocardiogram (ECG) markers currently being used in guidelines for patient selection, e.g., QRS duration and morphology. We shed light on the current knowledge on the underlying electrical substrate and the mechanism of action of CRT. Finally, we discuss potentially better ECG-based biomarkers for CRT candidate selection, of which the vectorcardiogram may have high potential.


Assuntos
Potenciais de Ação , Terapia de Ressincronização Cardíaca , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Seleção de Pacientes , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/terapia , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Valor Preditivo dos Testes , Volume Sistólico , Fatores de Tempo , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
10.
Heart Rhythm ; 12(5): 975-81, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25625721

RESUMO

BACKGROUND: Response to cardiac resynchronization therapy (CRT) remains challenging. Pacing from multiple sites of the left ventricle (LV) has shown promising results. OBJECTIVE: The purpose of this study was to systematically compare the acute hemodynamic effects of multipoint pacing (MPP) by means of a quadripolar lead with conventional biventricular (BiV) pacing. METHODS: Twenty-nine patients (23 men; mean age 72 ± 12 years; LV ejection fraction 29% ± 7%; 15 with ischemic cardiomyopathy, 17 with left bundle branch block; mean QRS 183 ± 23 ms) underwent CRT implantation. Per patient, 3.2 ± 1.2 different veins and 6.3 ± 2.4 pacing sites were tested. LV electrical delay (Q-LV) was measured at each location, along with the increase in LV dP/dtmax (maximum rate of rise of LV pressure) obtained by BiV and MPP. The effect of MPP, by means of simultaneous pacing from distal and proximal dipoles, was investigated at all available sites. RESULTS: Overall, 3.2 ± 1.2 different MPP measurements were collected per patient. When all sites were considered, LV dP/dtmax increased from 951 ± 193 mm Hg/s at baseline to 1144 ± 255 and 1178 ± 259 mm Hg/s on BiV and MPP, respectively. When the best site was considered, LV dP/dtmax increased from a baseline value of 942 ± 202 mm Hg/s to 1200 ± 267 mm Hg/s (BiV) and 1231 ± 267 mm Hg/s (MPP). The mean QRS duration at any site during MPP and conventional CRT was 171 ± 18 and 175 ± 16 ms (P = .003), respectively. CONCLUSION: Compared with BiV pacing at any LV site, MPP yielded a small but consistent increase in hemodynamic response. A correlation between the increase in hemodynamics and Q-LV on MPP was observed for all measurements, including those taken at the best and worst sites. The MPP-induced improvement in contractility was associated with significantly greater narrowing of the QRS complex than conventional BiV pacing.


Assuntos
Bloqueio de Ramo/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Cardiomiopatias/complicações , Insuficiência Cardíaca/terapia , Hemodinâmica , Volume Sistólico , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/classificação , Cardiomiopatias/fisiopatologia , Pesquisa Comparativa da Efetividade , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas/métodos , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ajuste de Prótese
11.
Europace ; 16 Suppl 4: iv56-iv61, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25362171

RESUMO

AIMS: Left-ventricular (LV) conduction disturbances are common in heart-failure patients and a left bundle-branch block (LBBB) electrocardiogram (ECG) type is often seen. The precise cause of this pattern is uncertain and is probably variable between patients, ranging from proximal interruption of the left bundle branch to diffuse distal conduction disease in the working myocardium. Using realistic numerical simulation methods and patient-tailored model anatomies, we investigated different hypotheses to explain the observed activation order on the LV endocardium, electrogram morphologies, and ECG features in two patients with heart failure and LBBB ECG. METHODS AND RESULTS: Ventricular electrical activity was simulated using reaction-diffusion models with patient-specific anatomies. From the simulated action potentials, ECGs and cardiac electrograms were computed by solving the bidomain equation. Model parameters such as earliest activation sites, tissue conductivity, and densities of ionic currents were tuned to reproduce the measured signals. Electrocardiogram morphology and activation order could be matched simultaneously. Local electrograms matched well at some sites, but overall the measured waveforms had deeper S-waves than the simulated waveforms. CONCLUSION: Tuning a reaction-diffusion model of the human heart to reproduce measured ECGs and electrograms is feasible and may provide insights in individual disease characteristics that cannot be obtained by other means.


Assuntos
Bloqueio de Ramo/fisiopatologia , Simulação por Computador , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Modelos Cardiovasculares , Potenciais de Ação , Idoso , Bloqueio de Ramo/diagnóstico , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Insuficiência Cardíaca/diagnóstico , Frequência Cardíaca , Humanos , Masculino , Análise Numérica Assistida por Computador , Valor Preditivo dos Testes , Função Ventricular Esquerda
12.
Europace ; 16(8): 1249-56, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24481779

RESUMO

AIMS: About one-third of patients with mild dyssynchronous heart failure suffer from atrial fibrillation (AF). Drugs that convert AF to sinus rhythm may further slowdown ventricular conduction. We aimed to investigate the electrophysiological and haemodynamic effects of vernakalant and flecainide in a canine model of chronic left bundle branch block (LBBB). METHODS AND RESULTS: Left bundle branch block was induced in 12 canines. Four months later, vernakalant or flecainide was administered using a regime, designed to achieve clinically used plasma concentrations of the drugs, n = 6 for each drug. Epicardial electrical contact mapping showed that both drugs uniformly prolonged myocardial conduction time. Vernakalant increased QRS width significantly less than flecainide (17 ± 13 vs. 34 ± 15%, respectively). Nevertheless, both drugs equally decreased LVdP/dtmax by ∼15%, LVdP/dtmin by ∼10%, and left ventricular systolic blood pressure by ∼5% (P = n.s. between drugs). CONCLUSIONS: Vernakalant prolongs ventricular conduction less than flecainide, but both drugs had a similar, moderate negative effect on ventricular contractility and relaxation. Part of these reductions seems to be related to the increase in dyssynchrony.


Assuntos
Anisóis/farmacologia , Antiarrítmicos/farmacologia , Bloqueio de Ramo/tratamento farmacológico , Flecainida/farmacologia , Sistema de Condução Cardíaco/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Pirrolidinas/farmacologia , Disfunção Ventricular Esquerda/tratamento farmacológico , Potenciais de Ação , Animais , Anisóis/sangue , Antiarrítmicos/sangue , Pressão Sanguínea/efeitos dos fármacos , Bloqueio de Ramo/sangue , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Doença Crônica , Modelos Animais de Doenças , Cães , Técnicas Eletrofisiológicas Cardíacas , Feminino , Flecainida/sangue , Sistema de Condução Cardíaco/fisiopatologia , Masculino , Contração Miocárdica/efeitos dos fármacos , Pirrolidinas/sangue , Fatores de Tempo , Disfunção Ventricular Esquerda/sangue , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/efeitos dos fármacos , Pressão Ventricular/efeitos dos fármacos
13.
Circ Arrhythm Electrophysiol ; 6(4): 682-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23873141

RESUMO

BACKGROUND: Simple conceptual ideas about cardiac resynchronization therapy assume that biventricular (BiV) pacing results in collision of right and left ventricular (LV) pacing-derived wavefronts. However, this concept is contradicted by the minor reduction in QRS duration usually observed. We investigated the electric mechanisms of cardiac resynchronization therapy by performing detailed electric mapping during extensive pacing protocols in dyssynchronous canine hearts. METHODS AND RESULTS: Studies were performed in anesthetized dogs with acute left bundle-branch block (LBBB, n=10) and chronic LBBB with tachypacing-induced heart failure (LBBB+HF, n=6). Activation times (AT) were measured using LV endocardial contact and noncontact mapping and epicardial contact mapping. BiV pacing reduced QRS duration by 21±10% in LBBB but only by 5±12% in LBBB+HF hearts. Transseptal impulse conduction was significantly slower in LBBB+HF than in LBBB hearts (67±9 versus 44±16 ms, respectively), and in both groups significantly slower than transmural LV conduction (≈30 ms). In both groups QRS duration and vector and the epicardial AT vector amplitude and angle were significantly different between LV and BiV pacing, whereas the endocardial AT vector was similar. During variation of atrioventricular delay while LV pacing, and ventriculo-ventricular delay while BiV pacing, the optimal hemodynamic effect was achieved when epicardial AT and QRS vectors were minimal and endocardial AT vector indicated LV preexcitation. CONCLUSIONS: Due to slow transseptal conduction, the LV electric activation sequence is similar in LV and BiV pacing, especially in failing hearts. Optimal hemodynamic cardiac resynchronization therapy response coincides with minimal epicardial asynchrony and QRS vector and LV preexcitation.


Assuntos
Bloqueio de Ramo/cirurgia , Terapia de Ressincronização Cardíaca , Sistema de Condução Cardíaco/cirurgia , Insuficiência Cardíaca/cirurgia , Potenciais de Ação , Animais , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Modelos Animais de Doenças , Cães , Técnicas Eletrofisiológicas Cardíacas , Mapeamento Epicárdico , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Masculino , Fatores de Tempo , Função Ventricular Esquerda , Função Ventricular Direita
14.
Europace ; 15(3): 453-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23027843

RESUMO

AIMS: Leadless pacing can be done by transmitting energy by an alternating magnetic field from a subcutaneous transmitter unit (TU) to an endocardial receiver unit (RU). Safety and energy consumption are key issues that determine the clinical feasibility of this new technique. The aims of the study were (i) to evaluate the stimulation characteristics of the non-rectangular pacing pulses induced by the alternating magnetic field, (ii) to determine the extent and impact of RU movement caused by the beating heart, and (iii) to evaluate the influence of the relative position between TU and RU on pacing efficiency and energy consumption. METHODS AND RESULTS: In the first step pacing efficiency and energy consumption for predefined positions were determined by bench testing. Subsequently, in a goat at five different ventricular sites (three in the right ventricle, two in the left ventricle) pacing thresholds using non-rectangular induction pulses were compared with conventional pulses. Relative position, defined by parallel distance, radial distance, and angulation between TU and RU, were determined in vivo by X-ray and an inclination angle measurement system. Bench testing showed that by magnetic induction for every alignment between TU and RU appropriate pulses can be produced up to a distance of 100 mm. In the animal experiment pacing thresholds were similar for non-rectangular pulses as compared with conventional pulse shapes. In all five positions with distances between 62 and 102 mm effective pacing was obtained in vivo. Variations in distance, displacement and angle caused by the beating heart did not cause loss of capture. At pacing threshold energy consumptions between 0.28 and 5.36 mJ were measured. Major determinants of energy consumption were distance and pacing threshold. CONCLUSION: For any given RU position up to a distance of 100 mm reliable pacing using induction can be obtained. In anatomically crucial distances, up to 60 mm energy consumption is within a reasonable range.


Assuntos
Estimulação Cardíaca Artificial/métodos , Frequência Cardíaca , Magnetoterapia/instrumentação , Marca-Passo Artificial , Função Ventricular , Animais , Simulação por Computador , Eletrocardiografia , Desenho de Equipamento , Cabras , Ventrículos do Coração/diagnóstico por imagem , Teste de Materiais , Modelos Animais , Modelos Cardiovasculares , Radiografia
15.
Am J Cardiol ; 106(4): 539-546.e2, 2010 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-20691313

RESUMO

Pacing experiments in healthy animal hearts have suggested a larger detrimental effect of septal compared to free wall preexcitation. We investigated the intrinsic relation among the site of electrical preexcitation, mechanical dyssynchrony, and dysfunction in human patients. In 33 patients with Wolff-Parkinson-White (WPW) syndrome and 18 controls, regional myocardial deformation was assessed by speckle tracking mapping (ST-Map) to assess the preexcitation site, shortening sequences and dyssynchrony, and the extent of local and global ejecting shortening. The ST-Map data in patients with accessory atrioventricular pathways correctly diagnosed as located in the interventricular septum (IVS) (n = 11) or left ventricular free wall (LFW) (n = 12) were compared to the corresponding control values. A local ejecting shortening of <2 SD of the control values identified hypokinetic segments. The localization of the atrioventricular pathways by ST-Map matched with the invasive electrophysiology findings in 23 of 33 patients and was one segment different in 5 of 33 patients. In both WPW-IVS and WPW-LFW, local ejecting shortening was impaired at the preexcitation site (p <0.01). However, at similar electrical and mechanical dyssynchrony, WPW-IVS had more extensive hypokinesia than did WPW-LFW (3.6 +/- 0.9 vs 1.8 +/- 1.3 segments, p <0.01). Compared to controls, the left ventricular function was significantly reduced only in WPW-IVS (global ejecting shortening 17 +/- 2% vs 19 +/- 2%, p = 0.01; ejection fraction 55 +/- 5% vs 59 +/- 3%, p = 0.02). In conclusion, preexcitation is associated with local hypokinesia, which at comparable preexcitation is more extensive in WPW-IVS than in WPW-LFW and could adversely affect ventricular function. ST-Map might have a future role in detecting and guiding treatment of septal pathways with significant mechanical effects.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Septo Interventricular/fisiopatologia , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/fisiopatologia , Adulto , Ablação por Cateter , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Síndrome de Wolff-Parkinson-White/etiologia , Síndrome de Wolff-Parkinson-White/terapia
16.
Circ Arrhythm Electrophysiol ; 3(4): 361-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20495014

RESUMO

BACKGROUND: Several studies suggest that patients with ischemic cardiomyopathy benefit less from cardiac resynchronization therapy. In a novel animal model of dyssynchronous ischemic cardiomyopathy, we investigated the extent to which the presence of infarction influences the short-term efficacy of cardiac resynchronization therapy. METHODS AND RESULTS: Experiments were performed in canine hearts with left bundle branch block (LBBB, n=19) and chronic myocardial infarction, created by embolization of the left anterior descending or left circumflex arteries followed by LBBB (LBBB+left anterior descending infarction [LADi; n=11] and LBBB+left circumflex infarction [LCXi; n=7], respectively). Pacing leads were positioned in the right atrium and right ventricle and at 8 sites on the left ventricular (LV) free wall. LV pump function was measured using the conductance catheter technique, and synchrony of electrical activation was measured using epicardial mapping and ECG. Average and maximal improvement in electric resynchronization and LV pump function by right ventricular+LV pacing was similar in the 3 groups; however, the site of optimal electrical and mechanical benefit was LV apical in LBBB hearts, LV midlateral in LBBB+LCXi hearts and LV basal-lateral in LBBB+LADi hearts. The best site of pacing was not the site of latest electrical activation but that providing the largest shortening of the QRS complex. During single-site LV pacing the range of atrioventricular delays yielding > or =70% of maximal hemodynamic effect was approximately 50% smaller in infarcted than noninfarcted LBBB hearts (P<0.05). CONCLUSIONS: Cardiac resynchronization therapy can improve resynchronization and LV pump function to a similar degree in infarcted and noninfarcted hearts. Optimal lead positioning and timing of LV stimulation, however, require more attention in the infarcted hearts.


Assuntos
Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Sistema de Condução Cardíaco/fisiopatologia , Hemodinâmica , Infarto do Miocárdio/fisiopatologia , Função Ventricular Esquerda , Animais , Bloqueio de Ramo/complicações , Bloqueio de Ramo/fisiopatologia , Modelos Animais de Doenças , Cães , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Masculino , Contração Miocárdica , Infarto do Miocárdio/complicações , Infarto do Miocárdio/patologia , Miocárdio/patologia , Recuperação de Função Fisiológica , Volume Sistólico , Fatores de Tempo , Pressão Ventricular
17.
Pacing Clin Electrophysiol ; 27(6 Pt 2): 837-43, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15189513

RESUMO

Pacing at the commonly used right ventricular (RV) apex results in impaired ventricular performance. Previous animal studies indicated that the left ventricular (LV) apex is a superior pacing site. The purpose of this study was to investigate in dogs whether this good performance is associated with a more synchronous electrical activation pattern of the LV and whether the LV apex is also a good pacing site in children. In 11 healthy dogs and 8 children undergoing cardiac surgery, dual chamber pacing was performed at the RV apex, LV apex and LV lateral free wall (LVFW). In dogs, a basket electrode was inserted into the LV to assess pattern and timing of LV endocardial activation. In the children, hemodynamic measurements were performed immediately after recovery from cardiopulmonary bypass. In dogs, LV apex pacing resulted in synchronous activation around the LV circumference whereas RV apex and LVFW pacing resulted in asynchrony of activation between the septum and LVFW. In both canine and children's hearts most hemodynamic variables remained at sinus rhythm level during LV apex pacing, but LVdPdtmax, stroke work (dogs), and pulse pressure (children) were reduced as compared with sinus rhythm during RV apex and LVFW pacing. LV apex pacing results in synchronous activation of the LV and is, in adult dogs and in children, associated with superior hemodynamic performance.


Assuntos
Estimulação Cardíaca Artificial/métodos , Cardiopatias Congênitas/fisiopatologia , Adolescente , Animais , Pré-Escolar , Cães , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração , Humanos , Lactente , Masculino , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS