Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiographics ; 43(5): e220158, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37022956

RESUMO

Photon-counting detector (PCD) CT is an emerging technology that has led to continued innovation and progress in diagnostic imaging after it was approved by the U.S. Food and Drug Administration for clinical use in September 2021. Conventional energy-integrating detector (EID) CT measures the total energy of x-rays by converting photons to visible light and subsequently using photodiodes to convert visible light to digital signals. In comparison, PCD CT directly records x-ray photons as electric signals, without intermediate conversion to visible light. The benefits of PCD CT systems include improved spatial resolution due to smaller detector pixels, higher iodine image contrast, increased geometric dose efficiency to allow high-resolution imaging, reduced radiation dose for all body parts, multienergy imaging capabilities, and reduced artifacts. To recognize these benefits, diagnostic applications of PCD CT in musculoskeletal, thoracic, neuroradiologic, cardiovascular, and abdominal imaging must be optimized and adapted for specific diagnostic tasks. The diagnostic benefits and clinical applications resulting from PCD CT in early studies have allowed improved visualization of key anatomic structures and radiologist confidence for some diagnostic tasks, which will continue as PCD CT evolves and clinical use and applications grow. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material. See the invited commentary by Ananthakrishnan in this issue.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Intensificação de Imagem Radiográfica/métodos , Fótons
2.
Radiology ; 303(1): 130-138, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34904876

RESUMO

Background The first clinical CT system to use photon-counting detector (PCD) technology has become available for patient care. Purpose To assess the technical performance of the PCD CT system with use of phantoms and representative participant examinations. Materials and Methods Institutional review board approval and written informed consent from four participants were obtained. Technical performance of a dual-source PCD CT system was measured for standard and high-spatial-resolution (HR) collimations. Noise power spectrum, modulation transfer function, section sensitivity profile, iodine CT number accuracy in virtual monoenergetic images (VMIs), and iodine concentration accuracy were measured. Four participants were enrolled (between May 2021 and August 2021) in this prospective study and scanned using similar or lower radiation doses as their respective clinical examinations performed on the same day using energy-integrating detector (EID) CT. Image quality and findings from the participants' PCD CT and EID CT examinations were compared. Results All standard technical performance measures met accreditation and regulatory requirements. Relative to filtered back-projection reconstructions, images from iterative reconstruction had lower noise magnitude but preserved noise power spectrum shape and peak frequency. Maximum in-plane spatial resolutions of 125 and 208 µm were measured for HR and standard PCD CT scans, respectively. Minimum values for section sensitivity profile full width at half maximum measurements were 0.34 mm (0.2-mm nominal section thickness) and 0.64 mm (0.4-mm nominal section thickness) for HR and standard PCD CT scans, respectively. In a 120-kV standard PCD CT scan of a 40-cm phantom, VMI iodine CT numbers had a mean percentage error of 5.7%, and iodine concentration had root mean squared error of 0.5 mg/cm3, similar to previously reported values for EID CT. VMIs, iodine maps, and virtual noncontrast images were created for a coronary CT angiogram acquired with 66-msec temporal resolution. Participant PCD CT images showed up to 47% lower noise and/or improved spatial resolution compared with EID CT. Conclusion Technical performance of clinical photon-counting detector (PCD) CT is improved relative to that of a current state-of-the-art CT system. The dual-source PCD geometry facilitated 66-msec temporal resolution multienergy cardiac imaging. Study participant images illustrated the effect of the improved technical performance. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Willemink and Grist in this issue.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Fótons , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
3.
Radiographics ; 41(1): 98-119, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33411614

RESUMO

Dual-energy CT (DECT) is a tremendous innovation in CT technology that allows creation of numerous imaging datasets by enabling discrete acquisitions at more than one energy level. The wide range of images generated from a single DECT acquisition provides several benefits such as improved lesion detection and characterization, superior determination of material composition, reduction in the dose of iodine, and more robust quantification. Technological advances and the proliferation of various processing methods have led to the availability of diverse vendor-based DECT approaches, each with a different acquisition and image reconstruction process. The images generated from various DECT scanners differ from those from conventional single-energy CT because of differences in their acquisition techniques, material decomposition methods, image reconstruction algorithms, and postprocessing methods. DECT images such as virtual monochromatic images, material density images, and virtual unenhanced images have different imaging appearances, texture features, and quantitative capabilities. This heterogeneity creates challenges in their routine interpretation and has certain associated pitfalls. Some artifacts such as residual iodine on virtual unenhanced images and an appearance of pseudopneumatosis in a gas-distended bowel loop on material-density iodine images are specific to DECT, while others such as pseudoenhancement seen on virtual monochromatic images are also observed at single-energy CT. Recognizing the potential pitfalls associated with DECT is necessary for appropriate and accurate interpretation of the results of this increasingly important imaging tool. Online supplemental material is available for this article. ©RSNA, 2021.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Artefatos , Humanos , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X
4.
Radiographics ; 40(5): 1284-1308, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32822281

RESUMO

Multienergy CT involves acquisition of two or more CT measurements with distinct energy spectra. Using the differential attenuation of tissues and materials at different x-ray energies, multienergy CT allows distinction of tissues and materials beyond that possible with conventional CT. Multienergy CT technologies can operate at the source or detector level. Dual-source, rapid tube-voltage switching, and dual-layer detector CT are the most commonly used multienergy CT technologies. Most of the currently available technologies typically use two energy levels, commonly referred to as dual-energy CT. With use of two or more energy bins, photon-counting detector CT can perform multienergy CT beyond current dual-energy CT technologies. Multienergy CT postprocessing can be performed in the projection or image domain using two-material or multimaterial decomposition. The most commonly used multienergy CT images are virtual monoenergetic images (VMIs), iodine maps, virtual noncontrast (VNC) images, and uric acid images. Low-energy VMIs are used to boost contrast signal and enhance lesion conspicuity. High-energy VMIs are used to decrease some artifacts. Iodine maps are used to evaluate perfusion, characterize lesions, and evaluate response to therapy. VNC images are used to characterize lesions and save radiation dose by eliminating true noncontrast images from multiphasic acquisitions. Uric acid images are used for characterization of renal calculi and gout. Online supplemental material is available for this article. ©RSNA, 2020.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Física
5.
Int J Cardiovasc Imaging ; 35(8): 1509-1524, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31049753

RESUMO

Multi-energy computed tomography (MECT) refers to acquisition of CT data at multiple energy levels (typically two levels) using different technologies such as dual-source, dual-layer and rapid tube voltage switching. In addition to conventional/routine diagnostic images, MECT provides additional image sets including iodine maps, virtual non-contrast images, and virtual monoenergetic images. These image sets provide tissue/material characterization beyond what is possible with conventional CT. MECT provides invaluable additional information in the evaluation of pulmonary vasculature, primarily by the assessment of pulmonary perfusion. This functional information provided by the MECT is complementary to the morphological information from a conventional CT angiography. In this article, we review the technique and applications of MECT in the evaluation of pulmonary vasculature.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Hemodinâmica , Hipertensão Pulmonar/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Imagem de Perfusão/métodos , Artéria Pulmonar/diagnóstico por imagem , Circulação Pulmonar , Embolia Pulmonar/diagnóstico por imagem , Humanos , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/terapia , Valor Preditivo dos Testes , Prognóstico , Artéria Pulmonar/fisiopatologia , Embolia Pulmonar/fisiopatologia , Embolia Pulmonar/terapia , Interpretação de Imagem Radiográfica Assistida por Computador
6.
Radiographics ; 37(7): 1955-1974, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29131773

RESUMO

Advances in scanner technology enabling shorter scan times, improvements in spatial and temporal resolution, and more dose-efficient data reconstruction coupled with rapidly growing evidence from clinical trials have established computed tomography (CT) as an important imaging modality in the evaluation of cardiovascular disorders. Multienergy (or spectral or dual-energy) CT is a relatively recent advance in which attenuation data from different energies are used to characterize materials beyond what is possible at conventional CT. Current technologies for multienergy CT are either source based (ie, dual source, rapid kilovoltage switching, dual spin, and split beam) or detector based (ie, dual layer and photon counting), and material-based decomposition occurs in either image or projection space. In addition to conventional diagnostic images, multienergy CT provides image sets such as iodine maps, virtual nonenhanced, effective atomic number, and virtual monoenergy (VM) images as well as data at the elemental level (CT fingerprinting), which can complement and in some areas overcome the limitations posed by conventional CT methods. In myocardial perfusion imaging, iodine maps improve the sensitivity of perfusion defects, and VM images improve the specificity by decreasing artifacts. Iodine maps are also useful in improving the performance of CT in delayed-enhancement imaging. In pulmonary perfusion imaging, iodine maps enhance the sensitivity of detection of both acute and chronic pulmonary emboli. Low-energy (as measured in kiloelectron volts) VM images allow enhancement of vascular contrast, which can either be used to lower contrast dose or salvage a suboptimal contrast-enhanced study. High-energy VM images can be used to decrease or eliminate artifacts such as beam-hardening and metallic artifacts. Virtual nonenhanced images have similar attenuation as true nonenhanced images and help in reducing radiation dose by eliminating the need for the latter in multiphasic vascular studies. Other potential applications of multienergy CT include calcium scoring from virtual nonenhanced images created from coronary CT angiograms and myocardial iron quantification. Online supplemental material is available for this article. ©RSNA, 2017.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador
SELEÇÃO DE REFERÊNCIAS