Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Acta Cardiol ; 68(4): 387-94, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24187765

RESUMO

BACKGROUND: Since their implementation in clinical practice, remote home monitoring systems (HM) have undoubtedly become an added value in patients with implantable devices for cardiac rhythm management. The aim of this study was to investigate the impact of HM on clinical management and outcome in patients with channelopathies and other arrhythmogenic diseases who received an implantable cardioverter defibrillator (ICD). METHODS: Fifty-four patients (age 6 months--74 years) were followed by means of HM in our ICD clinic. Alerts and/or device-related clinical events were analysed in all patients and subsequent clinical decisions were made if indicated. RESULTS: During an average observation time of 27 months, 46 alerts were received from 32 different patients. Five patients (9%) received appropriate therapies for life-threatening arrhythmias and four patients (8%) inappropriate therapies because ofT wave oversensing or supraventricular tachycardias. Three patients had alerts due to electrical noise (two on the atrial, one on the ventricular channel). Overall, 18 alerts (39%) required a modification of the pharmacological therapy or the programming of the device. Mean anticipation of clinical visits based on the alerts was 92.6 +/- 56 days (median 97, interquartile range 50-150). CONCLUSION: HM substantially improves the clinical management of patients with cardiac arrhythmogenic disease by early recognition of device-related inappropriate therapies and subsequent anticipation of treatment adaptation.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Eletrocardiografia Ambulatorial , Consulta Remota/métodos , Adulto , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/prevenção & controle , Arritmias Cardíacas/terapia , Bélgica , Diagnóstico Precoce , Eletrocardiografia Ambulatorial/efeitos adversos , Eletrocardiografia Ambulatorial/métodos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/métodos , Análise de Falha de Equipamento/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
3.
Europace ; 14(5): 661-5, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22117031

RESUMO

AIMS: Transseptal puncture (TP) appears to be safe in experienced hands; however, it can be associated with life-threatening complications. The aim of our study was to demonstrate the added value of routine use of transoesophageal echocardiography (TEE) for the correct positioning of the transseptal system in the fossa ovalis, thus potentially preventing complications during fluoroscopy-guided TP performed by inexperienced operators. METHODS AND RESULTS: Two hundred and five patients undergoing pulmonary vein isolation procedure (PVI) for drug-resistant paroxysmal or persistent atrial fibrillation were prospectively included. When the operator (initially blinded to TEE) assumed that the transseptal system was in a correct position according to fluoroscopical landmarks, the latter was then checked with TEE unblinding the physician. If necessary, further refinement of the catheter position was performed. Refinement >10 mm, or in case of catheter pointing directly at the aortic root or posterior wall were considered as major repositioning. Thirty-four patients required major repositioning. Regression analysis revealed age (P: 0.0001, Wald: 12.9, 95% confidence interval: 1.04-1.16), left atrial diameter (P: 0.01, Wald: 6.6, 95% confidence interval: 1.04-1.34), previous PVI (P: 0.01, Wald: 6.3, 95% confidence interval: 1.31-8.76), and atrial septal thickness (P: 0.03, Wald: 4.5, 95% confidence interval: 1.05-3.4) as independent predictors of major revision with TEE. CONCLUSION: Routine 2D TEE in addition to traditional fluoroscopic TP appears to be very useful to guide the TP assembly in a correct puncture position and thus, to avoid TP-related complications. However, further randomized prospective comparative studies are necessary to support these suggestions.


Assuntos
Fibrilação Atrial/cirurgia , Cardiologia/educação , Ablação por Cateter/métodos , Ecocardiografia Transesofagiana/métodos , Educação Médica Continuada/métodos , Punções/métodos , Adulto , Idoso , Fibrilação Atrial/diagnóstico por imagem , Cardiologia/normas , Ablação por Cateter/instrumentação , Ablação por Cateter/normas , Ecocardiografia Transesofagiana/normas , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fluoroscopia , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Humanos , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Punções/normas , Curva ROC
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA