Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
BMC Med Inform Decis Mak ; 22(1): 225, 2022 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-36031620

RESUMO

BACKGROUND AND OBJECTIVE: The automated detection of atrial activations (AAs) recorded from intracardiac electrograms (IEGMs) during atrial fibrillation (AF) is challenging considering their various amplitudes, morphologies and cycle length. Activation time estimation is further complicated by the constant changes in the IEGM active zones in complex and/or fractionated signals. We propose a new method which provides reliable automatic extraction of intracardiac AAs recorded within the pulmonary veins during AF and an accurate estimation of their local activation times. METHODS: First, two recently developed algorithms were evaluated and optimized on 118 recordings of pulmonary vein IEGM taken from 35 patients undergoing ablation of persistent AF. The adaptive mathematical morphology algorithm (AMM) uses an adaptive structuring element to extract AAs based on their morphological features. The relative-energy algorithm (Rel-En) uses short- and long-term energies to enhance and detect the AAs in the IEGM signals. Second, following the AA extraction, the signal amplitude was weighted using statistics of the AA sequences in order to reduce over- and undersensing of the algorithms. The detection capacity of our algorithms was compared with manually annotated activations and with two previously developed algorithms based on the Teager-Kaiser energy operator and the AF cycle length iteration, respectively. Finally, a method based on the barycenter was developed to reduce artificial variations in the activation annotations of complex IEGM signals. RESULTS: The best detection was achieved using Rel-En, yielding a false negative rate of 0.76% and a false positive rate of only 0.12% (total error rate 0.88%) against expert annotation. The post-processing further reduced the total error rate of the Rel-En algorithm by 70% (yielding to a final total error rate of 0.28%). CONCLUSION: The proposed method shows reliable detection and robust temporal annotation of AAs recorded within pulmonary veins in AF. The method has low computational cost and high robustness for automatic detection of AAs, which makes it a suitable approach for online use in a procedural context.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Algoritmos , Técnicas Eletrofisiológicas Cardíacas , Humanos
3.
Circ Arrhythm Electrophysiol ; 8(1): 18-24, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25528745

RESUMO

BACKGROUND: This study aimed to determine 5-year efficacy of catheter ablation for persistent atrial fibrillation (AF) using AF termination as a procedural end point. METHODS AND RESULTS: One hundred fifty patients (57±10 years) underwent persistent AF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided, and linear ablation) with the desired procedural end point being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia. AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3%±3.9%, 28.0%±3.7%, and 16.8%±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7%±2.5%, 79.8%±3.4%, and 62.9%±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (interquartile range, 43-73) months after the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs. Another 14 (9.3%) patients maintained sinus rhythm after reinitiation of antiarrhythmic drugs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (hazard ratio 3.831; 95% confidence interval, 2.070-7.143; P<0.001), left atrial diameter≥50 mm (hazard ratio 2.083; 95% confidence interval, 1.078-4.016; P=0.03), continuous AF duration≥18 months (hazard ratio 1.984; 95% confidence interval, 1.024-3.846; P<0.04), and structural heart disease (hazard ratio 1.874; 95% confidence interval, 1.037-3.388; P=0.04) predicted arrhythmia recurrence. CONCLUSIONS: In patients with persistent AF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow-up period. Procedural AF nontermination and specific baseline factors predict long-term outcome after ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Fatores de Risco , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento
4.
J Am Coll Cardiol ; 62(9): 802-12, 2013 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-23727084

RESUMO

OBJECTIVES: This study sought to evaluate the relationship between fibrosis imaged by delayed-enhancement (DE) magnetic resonance imaging (MRI) and atrial electrograms (Egms) in persistent atrial fibrillation (AF). BACKGROUND: Atrial fractionated Egms are strongly related to slow anisotropic conduction. Their relationship to atrial fibrosis has not yet been investigated. METHODS: Atrial high-resolution MRI of 18 patients with persistent AF (11 long-lasting persistent AF) was registered with mapping geometry (NavX electro-anatomical system (version 8.0, St. Jude Medical, St. Paul, Minnesota)). DE areas were categorized as dense or patchy, depending on their DE content. Left atrial Egms during AF were acquired using a high-density, 20-pole catheter (514 ± 77 sites/map). Fractionation, organization/regularity, local mean cycle length (CL), and voltage were analyzed with regard to DE. RESULTS: Patients with long-lasting persistent versus persistent AF had larger left atrial (LA) surface area (134 ± 38 cm(2) vs. 98 ± 9 cm(2), p = 0.02), a higher amount of atrial DE (70 ± 16 cm(2) vs. 49 ± 10 cm(2), p = 0.01), more complex fractionated atrial Egm (CFAE) extent (54 ± 16 cm(2) vs. 28 ± 15 cm(2), p = 0.02), and a shorter baseline AF CL (147 ± 10 ms vs. 182 ± 14 ms, p = 0.01). Continuous CFAE (CFEmean [NavX algorithm that quantifies Egm fractionation] <80 ms) occupied 38 ± 19% of total LA surface area. Dense DE was detected at the left posterior left atrium. In contrast, the right posterior left atrium contained predominantly patchy DE. Most CFAE (48 ± 14%) occurred at non-DE LA sites, followed by 41 ± 12% CFAE at patchy DE and 11 ± 6% at dense DE regions (p = 0.005 and p = 0.008, respectively); 19 ± 6% CFAE sites occurred at border zones of dense DE. Egms were less fractionated, with longer CL and lower voltage at dense DE versus non-DE regions: CFEmean: 97 ms versus 76 ms, p < 0.0001; local CL: 153 ms versus 143 ms, p < 0.0001; mean voltage: 0.63 mV versus 0.86 mV, p < 0.0001. CONCLUSIONS: Atrial fibrosis as defined by DE MRI is associated with slower and more organized electrical activity but with lower voltage than healthy atrial areas. Ninety percent of continuous CFAE sites occur at non-DE and patchy DE LA sites. These findings are important when choosing the ablation strategy in persistent AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/fisiopatologia , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Fibrose , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
J Cardiovasc Electrophysiol ; 24(4): 419-26, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23252727

RESUMO

BACKGROUND: Delayed enhancement (DE) MRI can assess the fibrotic substrate of scar-related VT. MDCT has the advantage of inframillimetric spatial resolution and better 3D reconstructions. We sought to evaluate the feasibility and usefulness of integrating merged MDCT/MRI data in 3D-mapping systems for structure-function assessment and multimodal guidance of VT mapping and ablation. METHODS: Nine patients, including 3 ischemic cardiomyopathy (ICM), 3 nonischemic cardiomyopathy (NICM), 2 myocarditis, and 1 redo procedure for idiopathic VT, underwent MRI and MDCT before VT ablation. Merged MRI/MDCT data were integrated in 3D-mapping systems and registered to high-density endocardial and epicardial maps. Low-voltage areas (<1.5 mV) and local abnormal ventricular activities (LAVA) during sinus rhythm were correlated to DE at MRI, and wall-thinning (WT) at MDCT. RESULTS: Endocardium and epicardium were mapped with 391 ± 388 and 1098 ± 734 points per map, respectively. Registration of MDCT allowed visualization of coronary arteries during epicardial mapping/ablation. In the idiopathic patient, integration of MRI data identified previously ablated regions. In ICM patients, both DE at MRI and WT at MDCT matched areas of low voltage (overlap 94 ± 6% and 79 ± 5%, respectively). In NICM patients, wall-thinning areas matched areas of low voltage (overlap 63 ± 21%). In patients with myocarditis, subepicardial DE matched areas of epicardial low voltage (overlap 92 ± 12%). A total number of 266 LAVA sites were found in 7/9 patients. All LAVA sites were associated to structural substrate at imaging (90% inside, 100% within 18 mm). CONCLUSION: The integration of merged MDCT and DEMRI data is feasible and allows combining substrate assessment with high-spatial resolution to better define structure-function relationship in scar-related VT.


Assuntos
Ablação por Cateter/métodos , Angiografia Coronária/métodos , Ventrículos do Coração/cirurgia , Imageamento por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Taquicardia Ventricular/terapia , Terapia Assistida por Computador , Adulto , Cicatriz/complicações , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Cicatriz/fisiopatologia , Meios de Contraste , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Fibrose , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Compostos Heterocíclicos , Humanos , Imageamento Tridimensional , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/patologia , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
6.
Circ Arrhythm Electrophysiol ; 5(5): 957-67, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22942219

RESUMO

BACKGROUND: To identify and understand clinically encountered pitfalls in the assessment of transmitral conduction block using differential coronary sinus and left atrial appendage pacing techniques in patients with left mitral isthmus linear ablation. METHODS AND RESULTS: All the available assessments of mitral isthmus block were thoroughly reviewed in 271 mitral isthmus ablation procedures undertaken among 236 patients from October 2008 to April 2011. Bidirectional block was established in 186 of 271 (69%) procedures. Careful evaluation of electrograms recorded on the multipolar coronary sinus and ablation catheters was undertaken to identify and understand the characteristics of pitfall, if any. Pitfall was encountered in 55 of 271 (20%) procedures among 51 patients and categorized into 6 types (types 1, 3, 4, and 5 led to spurious diagnosis of block; types 2 and 6 led to erroneous diagnosis of absence of block). There were 14, 10, 17, 2, 15, and 3 (total=61) cases of pitfall types 1 through 6, respectively. Operator recognized 42 of 61 (69%) pitfalls intraprocedurally. Recognition of types 1 and 5 was difficult because of indiscernible electrograms at usual amplifier settings or presence of slow conduction mimicking block. CONCLUSIONS: Every fifth assessment of bidirectional block across mitral isthmus linear lesion using differential coronary sinus and left atrial appendage pacing techniques encounters a pitfall, which can lead to erroneous clinical diagnosis of block or absence of block. Recognition of pitfall during the procedure is feasible and necessitates careful distinction of far-field left atrium from the local coronary sinus electrograms besides appropriate adjustments in catheter position and pacing outputs.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/cirurgia , Estimulação Cardíaca Artificial/métodos , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Distribuição de Qui-Quadrado , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Prevalência , Estudos Retrospectivos
7.
Curr Cardiol Rev ; 8(4): 327-46, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22920482

RESUMO

Atrial fibrillation (AF) ablation has evolved to the treatment of choice for patients with drug-resistant and symptomatic AF. Pulmonary vein isolation at the ostial or antral level usually is sufficient for treatment of true paroxysmal AF. For persistent AF ablation, drivers and perpetuators outside of the pulmonary veins are responsible for AF maintenance and have to be targeted to achieve satisfying arrhythmia-free success rate. Both complex fractionated atrial electrogram (CFAE) ablation and linear ablation are added to pulmonary vein isolation for persistent AF ablation. Nevertheless, ablation failure and necessity of repeat ablations are still frequent, especially after persistent AF ablation. Pulmonary vein reconduction is the main reason for arrhythmia recurrence after paroxysmal and to a lesser extent after persistent AF ablation. Failure of persistent AF ablation mostly is a consequence of inadequate trigger ablation, substrate modification or incompletely ablated or reconducting linear lesions. In this review we will discuss these points responsible for AF recurrence after ablation and review current possibilities on how to overcome these limitations.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Angioplastia Coronária com Balão/métodos , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Humanos , Magnetismo , Robótica/métodos
8.
J Cardiovasc Electrophysiol ; 23(5): 553-5, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22487050

RESUMO

This is a case of atrial tachycardia 2 years after pulmonary transplantation. After excluding right atrial involvement, tachycardia origin was located in a scar region medial to the anastomosis of the left inferior pulmonary donor vein. Tachycardia mechanism was microreentry. Noninvasive electrocardiographic mapping performed before the ablation procedure matched with results of invasive Carto mapping and predicted both tachycardia mechanism and origin. We discuss arrhythmia mechanism found after pulmonary transplantation and benefit of noninvasive electrocardiographic mapping for procedure planning.


Assuntos
Função Atrial , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Transplante de Pulmão/efeitos adversos , Veias Pulmonares/cirurgia , Taquicardia Supraventricular/diagnóstico , Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Fatores de Tempo , Imagens com Corantes Sensíveis à Voltagem
9.
J Cardiovasc Electrophysiol ; 23(7): 697-707, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22429828

RESUMO

INTRODUCTION: Persistent atrial fibrillation (AF) ablation may lead to partial disconnection of the coronary sinus (CS). As a result, disparate activation sequences of the local CS versus contiguous left atrium (LA) may be observed during atrial tachycardia (AT). We aimed to evaluate the prevalence of this phenomenon and its impact on activation mapping. METHODS: AT occurring after persistent AF ablation were investigated in 74 consecutive patients. Partial CS disconnection during AT was suspected when double potentials with disparate activation sequences were observed on the CS catheter. Endocardial mapping facing CS bipoles was performed to differentiate LA far-field from local CS potentials. RESULTS: A total of 149 ATs were observed. Disparate LA-CS activations were apparent in 20 ATs after magnifying the recording scale (13%). The most common pattern (90%) was distal to proximal endocardial LA activation against proximal to distal CS activation, the latter involving the whole CS or its distal part. Perimitral macroreentry was more common when disparate LA-CS activations were observed (67% vs 29%; P = 0.002). Partial CS disconnection also resulted in "pseudo" mitral isthmus (MI) block during LA appendage pacing in 20% of patients as local CS activation was proximal to distal despite distal to proximal activation of the contiguous LA. CONCLUSION: Careful analysis of CS recordings during AT following persistent AF ablation often reveals disparate patterns of activation. Recognizing when endocardial LA activation occurs in the opposite direction to the more obvious local CS signals is critical to avoid misleading interpretations during mapping of AT and evaluation of MI block.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Seio Coronário/fisiopatologia , Taquicardia Supraventricular/diagnóstico , Imagens com Corantes Sensíveis à Voltagem , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , França , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Taquicardia Supraventricular/epidemiologia , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo
10.
J Cardiovasc Electrophysiol ; 23(5): 489-96, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22229972

RESUMO

OBJECTIVE: To evaluate the safety and outcomes of mitral isthmus (MI) linear ablation with temporary spot occlusion of the coronary sinus (CS). BACKGROUND: CS blood flow cools local tissue precluding transmurality and bidirectional block across MI lesion. METHODS: In a randomized, controlled trial (CS-occlusion = 20, Control = 22), MI ablation was performed during continuous CS pacing to monitor the moment of block. CS was occluded at the ablation site using 1 cm spherical balloon, Swan-Ganz catheter with angiographic confirmation. Ablation was started at posterior mitral annulus and continued up to left inferior pulmonary vein (LIPV) ostium using an irrigated-tip catheter. If block was achieved, balloon was deflated and linear block confirmed. If not, additional ablation was performed epicardially (power ≤25 W). Ablation was abandoned after ∼30 minutes, if block was not achieved. RESULTS: CS occlusion (mean duration -27 ± 9 minutes) was achieved in all cases. Complete MI block was achieved in 13/20 (65%) and 15/22 (68%) patients in the CS-occlusion and control arms, respectively, P = 0.76. Block was achieved with significantly small number (0.5 ± 0.8 vs 1.9 ± 1.1, P = 0.0008) and duration (1.2 ± 1.7 vs 4.2 ± 3.5 minutes, P = 0.009) of epicardial radiofrequency (RF) applications and significantly lower amount of epicardial energy (1.3 ± 2.4 vs 6.3 ± 5.7 kJ, P = 0.006) in the CS-occlusion versus control arm, respectively. There was no difference in total RF (22 ± 9 vs 23 ± 11 minutes, P = 0.76), procedural (36 ± 16 vs 39 ± 20 minutes, P = 0.57), and fluoroscopic (13 ± 7 vs 15 ± 10 minutes, P = 0.46) durations for MI ablation between the 2 arms. Clinically uneventful CS dissection occurred in 1 patient CONCLUSIONS: Temporary spot occlusion of CS is safe and significantly reduces the requirement of epicardial ablation to achieve MI block. It does not improve overall procedural success rate and procedural duration. Tissue cooling by CS blood flow is just one of the several challenges in MI ablation.


Assuntos
Fibrilação Atrial/cirurgia , Oclusão com Balão , Ablação por Cateter , Seio Coronário , Valva Mitral/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Oclusão com Balão/efeitos adversos , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Angiografia Coronária , Seio Coronário/diagnóstico por imagem , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA