Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 42(2): 216-223, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30536679

RESUMO

INTRODUCTION: Adjunctive driver-guided ablation in addition to pulmonary vein isolation has been proposed as a strategy to improve procedural success and outcomes for various populations with atrial fibrillation (AF). First, this study aimed to evaluate the different mapping techniques for driver/rotor identification and second to evaluate the benefits of driver/rotor-guided ablation in patients with paroxysmal and persistent AF (PerAF). METHODS: We searched the electronic database in PubMed using the keywords "atrial fibrillation," "rotor," "rotational driver," "atrial fibrillation source," and "drivers" for both randomized controlled trials and observational controlled trials. Clinical studies reporting efficacy or safety outcomes of driver-guided ablation for paroxysmal AF or (PerAF) were identified. We performed subgroup analyses comparing different driver mapping methods in patients with PerAF. The odds ratios (ORs) with random effects were analyzed. RESULTS: Out of 175 published articles, seven met the inclusion criteria, of which two were randomized controlled trials, one was quasiexperimental study, and four observational studies (three case-controlled studies and one cross-sectional study). Overall, adjunctive driver-guided ablation was associated with higher rates of acute AF termination (OR: 4.62, 95% confidence interval [CI]: 2.12-10.08; P < 0.001), lower recurrence of any atrial arrhythmia (OR: 0.44, 95% CI: 0.30-0.065; P < 0.001), and comparable complication incidence. CONCLUSIONS: Adjunctive driver-guided catheter ablation suggested an increased freedom from AF/AT relative to conventional strategies, irrespective of the mapping techniques. Furthermore, phase mapping appears to be superior to electrogram-based driver mapping in PerAF ablation.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Humanos , Estudos Observacionais como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
Int J Cardiol ; 272: 90-96, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30173923

RESUMO

BACKGROUND: Intracardiac electrogram recording is influenced by the electrode size and inter-electrode spacing. Smaller electrodes with a closer inter-electrode spacing may improve the mapping resolution and outcome. METHODS: Substrate mapping of the left atrium and residual pulmonary vein (PV) potentials during sinus rhythm was sequentially performed using a 3.5-mm electrode tip catheter and a 1-mm electrode multielectrode catheter in 33 patients (Group 1) that underwent repeat atrial fibrillation (AF) procedures. PV gap identification and electrophysiological characteristics were compared. Arrhythmia freedom was compared with a propensity matched (1:2) control group (66 patients, Group 2) undergoing repeat AF procedures guided by wide inter-electrode spacing catheter. RESULTS: In the Group 1 patients, the total area of residual PV potentials measured using the 1-mm catheter was larger than that measured by the 3.5-mm catheter. Overall 1.97 ±â€¯0.59 (1-3) and 1.49 ±â€¯0.62 (1-3) PVs were identified by the 1-mm electrode and 3.5 mm catheters, respectively (P = 0.02). The gaps not identified by the 3.5 mm catheter had a smaller width and lower voltage. Radiofrequency catheter ablation in the areas with residual PV potentials identified by the 1-mm catheter resulted in complete electrical isolation of the PVs. Arrhythmia freedom at one year of follow-up was achieved in 26 of 33 (78.8%) patients in Group 1, which was significantly higher than the matched control group (33/66 [50%], P < 0.05). CONCLUSION: In the patients with a previous PV isolation, mapping with small, closely spaced electrodes can increase the detection rate of residual PV potentials and improve the outcome.


Assuntos
Ablação por Cateter/instrumentação , Eletrocardiografia/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia por Tomografia Computadorizada/métodos , Eletrocardiografia/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Humanos , Masculino , Microeletrodos , Pessoa de Meia-Idade , Estudos Prospectivos
3.
J Cardiovasc Electrophysiol ; 29(5): 699-706, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29424013

RESUMO

INTRODUCTION: Cigarette smoking contributes to the development of atrial fibrosis via nicotine. The impact of smoking on ablation results in persistent atrial fibrillation (AF) is unknown. We aimed to investigate the triggers and long-term outcome between smokers and nonsmokers in the patients with persistent AF after catheter ablation. METHODS: This study included 201 (177 males, 53 ± 10 years old) patients who received index catheter ablation, including pulmonary vein isolation (PVI) and complex fractionated atrial electrograms (CFAEs) ablation for persistent AF, retrospectively. Electrophysiological characteristics at the index procedure and long-term outcome were investigated to determine the differences between smokers and nonsmokers. RESULTS: Baseline characteristics were similar between two groups. Pulmonary vein (PV) triggers were found in all patients in the two groups. There was a higher incidence of nonpulmonary vein (NPV) triggers in smokers than in nonsmokers (61% vs. 31%, P < 0.05). There were no differences of the long-term ablation outcomes between smokers and nonsmokers in Kaplan-Meier analysis. Smokers with PV plus right atrial NPV (RA-NPV) triggers had a higher incidence of recurrence (log-rank P < 0.05) than those without RA-NPV triggers, but not in nonsmokers, after a mean follow-up of 31 ± 25 months. CONCLUSIONS: Smoking increases the incidence of NPV triggers in patients with persistent AF. Smokers who have RA-NPV triggers during index procedure do have a worse outcome after catheter ablation, indicating the harmful effects of nicotine to right atrium.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Fumar/efeitos adversos , Potenciais de Ação , Adulto , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Nicotina/efeitos adversos , Agonistas Nicotínicos/efeitos adversos , não Fumantes , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fumantes , Fumar/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 29(2): 298-307, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29071756

RESUMO

BACKGROUND: Septal ventricular outflow tract ventricular arrhythmias (OT-VAs) are defined as septal origin VAs from the right ventricular or left ventricular OT. Patients with septal OT-VAs may require a sequential bilateral OT ablation. This study aimed to evaluate the electrophysiological characteristics and ablation outcome in patients with septal OT-VAs. METHODS: We retrospectively analyzed the electrocardiography and electrophysiological parameters in 96 patients (mean age 49 ± 15 years, 49 male) undergoing bilateral activation mapping before catheter ablation of idiopathic septal OT-VAs. The patients were categorized into three groups based on the successful ablation sites, including the right ventricular outflow tract (RVOT), RVOT/left ventricular outflow tract (LVOT), and LVOT. RESULTS: Mapping in the three groups demonstrated a gradually decreasing and increasing trend in the earliest activation time obtained from the RVOT and LVOT, respectively. The absolute earliest activation time discrepancy (AEAD) of ≤18 milliseconds could predict the requirement for a sequential bilateral ablation with a sensitivity and specificity of 100.0% and 93.7%, respectively. The small AEAD (≤21 milliseconds) was associated with a higher recurrence rate in patients receiving a successful unilateral ablation, while patients with a longer distance between the bilateral OT earliest activation sites (DEA > 26 mm) increased future recurrences after an initially successful sequential bilateral ablation. CONCLUSIONS: The application of bilateral OT-VA activation mapping and the measurement of the AEAD and DEA provided not only pivotal information for the ablation strategy, but also prognostic implications for recurrences in patients with septal OT-VAs.


Assuntos
Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/cirurgia , Septo Interventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular Direita , Septo Interventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA