Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 523(7562): 543-9, 2015 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-26153860

RESUMO

Volcanic eruptions contribute to climate variability, but quantifying these contributions has been limited by inconsistencies in the timing of atmospheric volcanic aerosol loading determined from ice cores and subsequent cooling from climate proxies such as tree rings. Here we resolve these inconsistencies and show that large eruptions in the tropics and high latitudes were primary drivers of interannual-to-decadal temperature variability in the Northern Hemisphere during the past 2,500 years. Our results are based on new records of atmospheric aerosol loading developed from high-resolution, multi-parameter measurements from an array of Greenland and Antarctic ice cores as well as distinctive age markers to constrain chronologies. Overall, cooling was proportional to the magnitude of volcanic forcing and persisted for up to ten years after some of the largest eruptive episodes. Our revised timescale more firmly implicates volcanic eruptions as catalysts in the major sixth-century pandemics, famines, and socioeconomic disruptions in Eurasia and Mesoamerica while allowing multi-millennium quantification of climate response to volcanic forcing.


Assuntos
Clima , Temperatura , Erupções Vulcânicas/história , Aerossóis/análise , América , Regiões Antárticas , Atmosfera/química , Berílio , Radioisótopos de Carbono , Desastres/história , Europa (Continente) , Groenlândia , História Antiga , História Medieval , Gelo/análise , Radioisótopos , Datação Radiométrica , Estações do Ano , Enxofre , Fatores de Tempo , Árvores/anatomia & histologia , Árvores/crescimento & desenvolvimento , Clima Tropical
2.
Clin Orthop Relat Res ; (379): 85-93, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11039796

RESUMO

The current authors review clinical and retrieval experiences with hemispheric monolithic alumina ceramic sockets (Group 1), implanted between 1976 and 1979, and similar modular titanium sockets with alumina ceramic inlays (Group 2), implanted between 1990 and 1995. Both cementless sockets articulated with alumina ceramic femoral ball heads for total hip joint replacements. Clinical followup of patients with hemispheric monolithic alumina ceramic sockets (Group 1, 138 sockets) resulted in a total failure rate of 19.6% after 5 to 20 years. Radiologic analysis of eight stable sockets showed migration of 0.2 mm to 2.89 mm, but in four sockets at risk for late aseptic failure after an average followup of 12.5 years as much as 13.4 mm of migration was seen. Histologic evaluation revealed pseudosynovial membranes as thick as 1 mm with fine birefringent wear particles within mononuclear macrophages around two stable retrieved sockets. The membranes around four loose sockets were 6 to 10 mm thick and also heavily loaded with larger alumina wear particles. After 7 years followup clinical analysis of patients with modular titanium sockets with alumina ceramic inlays (Group 2, 30 sockets) resulted in four revisions, compared with one revision of 50 identical sockets (control group) with polyethylene instead of alumina ceramic inlays. Wear particle analyses in scanning electron microscopy showed significantly more particles (x 10(9) +/- standard deviation/g dry tissue) from the control group (4.26+/-6.38), compared with alumina ceramic bearings of Group 1 (0.70+/-0.79), and of Group 2 (1.62+/-2.13). The alumina particle sizes ranged between 0.13 and 78.38 microm. The mean annual linear wear of 38.8 microm was calculated for the bearings in Group 1, and of 26.94 microm for bearings in Group 2. These results support the good tribologic and biologic performance of alumina ceramic bearings for total hip arthroplasty.


Assuntos
Óxido de Alumínio , Prótese de Quadril , Artroplastia de Quadril , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Radiografia , Titânio
3.
J Bone Joint Surg Br ; 82(6): 901-9, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10990321

RESUMO

We compared wear particles from two different designs of total hip arthroplasty with polycrystalline alumina-ceramic bearings of different production periods (group 1, before ISO 6474: group 2, according to ISO 6474). The neocapsules and interfacial connective tissue membranes were retrieved after mean implantation times of 131 months and 38 months, respectively. Specimen blocks were freed from embedding media, either methylmethacrylate or paraffin and digested in concentrated nitric acid. Particles were then counted and their sizes and composition determined by SEM and energy-dispersive x-ray analysis (EDXA). The mean numbers and sizes of most alumina wear particles did not differ for both production periods, but the larger sizes of particle in group 1 point to more severe surface destruction. The increased metal wear in group 2 was apparently due to alumina-induced abrasion of the stems. In this study the concentrations of particles in the periprosthetic tissues were 2 to 22 times lower than those observed previously with polyethylene and alumina/polyethylene wear couples.


Assuntos
Óxido de Alumínio/efeitos adversos , Artroplastia de Quadril/instrumentação , Cerâmica/efeitos adversos , Tecido Conjuntivo/patologia , Prótese de Quadril/efeitos adversos , Falha de Prótese , Adulto , Idoso , Biópsia , Microanálise por Sonda Eletrônica , Análise de Falha de Equipamento , Prótese de Quadril/provisão & distribuição , Humanos , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Tamanho da Partícula , Desenho de Prótese , Fatores de Tempo
4.
J Bone Joint Surg Br ; 76(1): 53-9, 1994 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8300682

RESUMO

We report the clinical and tribological performance of 67 ceramic acetabular prostheses implanted between 1976 and 1979 without bone cement. They articulated with ceramic femoral heads mounted on mental femoral stems. After a mean elapsed period of 144 months, 59 sockets were radiographically stable but two showed early signs and six showed late signs of loosening. Four of the loose sockets have been revised. Histological analysis of the retrieved tissue showed a fibrous membrane around all the implants, with fibrocartilage in some. There was no bone ingrowth, and the fibrous membrane was up to 6 mm thick and infiltrated with lymphocytes, plasma cells, and macrophages. Intra- and extracellular birefringent wear particles were seen. Tribological analysis showed total wear rates in two retrieved alumina-on-alumina joints of 2.6 microns per year in a stable implant and 68 microns in a loose implant. Survival analysis showed a revision rate of 12.4% at 136 months.


Assuntos
Óxido de Alumínio , Cimentação , Prótese de Quadril , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Humanos , Tábuas de Vida , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação , Propriedades de Superfície
5.
Clin Orthop Relat Res ; (134): 80-6, 1978.
Artigo em Inglês | MEDLINE | ID: mdl-729270

RESUMO

A cement-free bioceramic aluminum oxide double cup endoprosthesis is under investigation as an alternative to the cemented stem endoprosthesis. Nine patients with 11 operated hips are without complaints after an average of 20.8 months (range 8--28 months). Early loosening of 2 femoral components occurred because of technical mistakes during operation. In 3 patients loosening of the femoral component was seen 5--7 months after surgery. Mobilization of the hip joint and walking capacity are similar to the usually implanted stem endoprosthesis. Stable long-lasting anchorage is possible if the femoral component is implanted in valgus position and in contact with living bone. Failures are treated by a traditional type of endoprosthesis.


Assuntos
Artroplastia/métodos , Articulação do Quadril/cirurgia , Prótese Articular , Adulto , Idoso , Óxido de Alumínio , Artrite Reumatoide/cirurgia , Materiais Biocompatíveis , Cimentos Ósseos , Cerâmica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Complicações Pós-Operatórias , Desenho de Prótese
6.
Clin Orthop Relat Res ; (132): 252-65, 1978 May.
Artigo em Inglês | MEDLINE | ID: mdl-679548

RESUMO

Dense, highly pure A12O3 ceramic not only shows excellent wear resistance and tissue biocompatibility, but also has sufficient mechanical strength for loaded endoprostheses. The necessary diameter size of the material to sustain adequate shear stresses can be achieved, if the endoprosthesis is attached extracortically to the conically truncated long bone according to the principle of the conical sleeve. Extracortical attachment of the endoprosthesis causes minor nutritive damage since long bones derive their vascular supply mainly from the medullary cavity. In this way a primary stable and loadable connection is established, which is a prerequisite for permanent anchorage of the implant through new bone formation. After experiments in 12 dogs bioceramic endoprostheses were implanted in a total of 40 human patients using this technique of extracortical attachment (12 hip joints, 24 proximal humeri, 4 special constructions). Thirty-six of these implants were stable after observation periods ranging from one to 49 months. A stable anchorage of the prostheses to the pre-existing bone through new bone formation could be demonstrated histologically. The above preliminary results show that bioceramic endoprostheses can be "incorporated" in the skeleton and possibly also withstand the functional stresses.


Assuntos
Materiais Biocompatíveis , Prótese Articular , Adulto , Idoso , Óxido de Alumínio , Animais , Cimentos Ósseos , Pinos Ortopédicos , Parafusos Ósseos , Cerâmica , Cães , Feminino , Articulação do Quadril/cirurgia , Humanos , Úmero/cirurgia , Prótese Articular/instrumentação , Masculino , Pessoa de Meia-Idade , Próteses e Implantes/instrumentação
SELEÇÃO DE REFERÊNCIAS