Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Chim Acta ; 430: 28-32, 2014 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-24370386

RESUMO

BACKGROUND: Orotic acid (OA) is the key parameter in the detection of ornithine transcarbamylase deficiency (OTC-D). Inclusion of OA into newborn screening compatibility with existing analytical procedures is necessary. METHODS: OA was eluted from dried blood spots with methanol containing deuterated [1,3-(15)N2] OA as internal standard. Quantification by tandem mass spectrometry was accomplished without chromatographic separation. Samples were measured in MRM mode for the masses m/z 155.1 → 111 for OA and 157.1 → 113 for d2 OA. RESULTS: OA was determined in a wide range of concentrations with high precision, LOD and LOQ being 0.21 and 0.65 µmol/L, respectively. Values correlated well with those obtained after chromatography. Pretreatment of samples with HCl-butanol regularly used for acylcarnitine measurement did not significantly affect quantitative results. Inclusion of the new method into the standard newborn screening procedure did not alter the results for acylcarnitines or amino acids; the total time per analysis, however, was increased from 1.15 to 1.85 min. OA levels of 707 unaffected newborns ranged from 0.28 to 3.73 µmol/L. Five newborns with OTC-D showed concentrations of 89.7-211.1 µmol/L. In newborns with severe citrullinaemia we found values in the range of 4.99-127.7 µmol/L. CONCLUSIONS: This new method can be used as a standalone measurement of OA but it can also easily be implemented into standard newborn screening techniques as a useful supplement. In this case the method allows detection of newborns with OTC deficiency without an extra analytical run.


Assuntos
Teste em Amostras de Sangue Seco , Triagem Neonatal/métodos , Doença da Deficiência de Ornitina Carbomoiltransferase/sangue , Doença da Deficiência de Ornitina Carbomoiltransferase/diagnóstico , Ácido Orótico/sangue , Espectrometria de Massas em Tandem , Humanos , Recém-Nascido , Doença da Deficiência de Ornitina Carbomoiltransferase/metabolismo
2.
Pediatr Neurol ; 28(3): 228-30, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12770680

RESUMO

We report a patient with BH(4)-sensitive phenylketonuria. In neonatal screening, phenylalanine levels above 10 mg/dl were detected. In the tetrahydrobiopterin- (BH(4)) loading test, phenylalanine concentrations in serum fell significantly. Dihydropteridine reductase activity in blood, pterines, and neurotransmitters in cerebrospinal fluid, as well as pterines in urine were all normal. Mutation analysis revealed compound-heterozygosity for the mutations R408W and K320N. Under BH(4)-supplementation without a specific phenylalanine-reduced diet, phenylalanine-concentrations are in the therapeutic range and our patient developed normally.


Assuntos
Biopterinas/análogos & derivados , Fenilcetonúrias/diagnóstico , Humanos , Lactente , Masculino , Fenilalanina/sangue , Fenilcetonúrias/sangue , Fenilcetonúrias/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA