Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Anal Bioanal Chem ; 415(5): 809-821, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36507958

RESUMO

The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material® (SRM®) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels. To produce SRM 3949, pilot sera were collected from 15 individual donors, 5 of whom were given a 400-µg folic acid supplement 1 h prior to blood draw to increase serum levels of 5mTHF and folic acid for the high-level material. To stabilize the folates, 0.5% (mass concentration) ascorbic acid was added as soon as possible after preparation of serum. These pilot sera were screened for five folates plus the pyrazino-s-triazine derivative of 4-α-hydroxy-5-methyltetrahydrofolate (MeFox) at the US Centers for Disease Control and Prevention (CDC) by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Based on these results, a blending protocol was specified to obtain the three desired folate concentrations for SRM 3949. ID-LC-MS/MS analysis at the CDC and NIST was utilized to assign values for folic acid and 5mTHF, as well as several minor folates.


Assuntos
Ácido Fólico , Espectrometria de Massas em Tandem , Humanos , Ácido Fólico/análise , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Padrões de Referência , Ácido Ascórbico
2.
J Chromatogr A ; 1574: 114-121, 2018 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-30220428

RESUMO

The research presented here describes the development of two analytical methods for use in the certification of a ginsenoside calibration solution Standard Reference Material (SRM) 3389 consisting of seven ginsenosides: Rg1, Re, Rf, Rb1, Rc, Rb2, and Rd. The new methods utilized the liquid chromatographic (LC) separation of ginsenoside mixtures with absorbance detection (UV) and mass spectrometry (MS). Ginsenosides Rb3, Rg2, Rg3, Rh1, and Rh2 were evaluated for use as internal standards for LC/MS measurements. The 12 ginsenosides were baseline resolved by gradient elution LC/UV, with an initial mobile phase composition of 22% acetonitrile and 78% water, flow rate of 0.7 mL/min, and column temperature of 25 °C. The work presented here includes a detailed investigation into the optimization of the chromatographic conditions to minimize measurement biases that result from unresolved constituents. Temperature and mobile phase composition are known to play a significant role in column selectivity; however, flow rate is expected to influence primarily the separation efficiency and detection sensitivity. In the current study, column selectivity changed with changes in flow rate and the relative retention of ginsenoside Rg2 and Rh1 changed as the flow rate increased from 0.6 mL/min to 1.0 mL/min.


Assuntos
Calibragem , Técnicas de Química Analítica/métodos , Técnicas de Química Analítica/normas , Cromatografia Líquida , Ginsenosídeos/análise , Espectrometria de Massas em Tandem , Acetonitrilas , Técnicas de Química Analítica/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Panax/química , Padrões de Referência
3.
J AOAC Int ; 100(5): 1294-1303, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28917261

RESUMO

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements and the Vitamin D Standardization Program, has recently issued a new serum-matrix Standard Reference Material (SRM): 2973 Vitamin D Metabolites in Frozen Human Serum (High Level). SRM 2973 was designed to provide a serum material with a total 25-hydroxyvitamin D [25(OH)D] concentration near 100 nmol/L to complement the existing serum-based SRMs with values assigned for total 25(OH)D between 20 and 80 nmol/L. Values were assigned for 25-hydroxyvitamin D2 [25(OH)D2], 25-hydroxyvitamin D3 [25(OH)D3], 3-epi-25(OH)D3, and total 25(OH)D [the sum of 25(OH)D2 + 25(OH)D3] using the NIST isotope dilution LC with tandem MS (MS/MS) reference measurement procedure (RMP) and related methods. SRM 2973 has a certified value of 98.4 ± 2.1 nmol/L for 25(OH)D3 and reference values of 1.59 ± 0.05 nmol/L for 25(OH)D2 and 5.23 ± 0.20 nmol/L for 3-epi-25(OH)D3. In addition, a candidate RMP for 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3] based on LC-MS/MS was used to assign values to SRM 2973 and the existing SRM 972a Vitamin D Metabolites in Frozen Human Serum. Reference values for 24R,25(OH)2D3 were assigned to SRM 2973 (7.51 ± 0.26 nmol/L) and the four levels of SRM 972a: Level 1 (6.38 ± 0.23 nmol/L), Level 2 (3.39 ± 0.12 nmol/L), Level 3 (3.88 ± 0.013 nmol/L), and Level 4 (6.32 ± 0.22 nmol/L). The development of SRM 2973 [with a higher concentration of 25(OH)D3] and the addition of values for 24R,25(OH)2D3 assigned to both SRM 972a and SRM 2973 provide laboratories involved in vitamin D measurements with improved QA tools.


Assuntos
25-Hidroxivitamina D 2/sangue , Análise Química do Sangue/normas , Calcifediol/sangue , Humanos , Espectrometria de Massas em Tandem/normas , Estados Unidos , Vitamina D
4.
J AOAC Int ; 100(5): 1260-1276, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28863788

RESUMO

Since 2005, the National Institute of Standards and Technology (NIST) has collaborated with the National Institutes of Health (NIH), Office of Dietary Supplements (ODS) to improve the quality of measurements related to human nutritional markers of vitamin D status. In support of the NIH-ODS Vitamin D Initiative, including the Vitamin D Standardization Program (VDSP), NIST efforts have focused on (1) development of validated analytical methods, including reference measurement procedures (RMPs); (2) development of Standard Reference Materials (SRMs); (3) value assignment of critical study samples using NIST RMPs; and (4) development and coordination of laboratory measurement QA programs. As a result of this collaboration, NIST has developed RMPs for 25-hydroxyvitamin D2 [25(OH)D2], 25(OH)D3, and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3]; disseminated serum-based SRMs with values assigned for 25(OH)D2, 25(OH)D3, 3-epi-25(OH)D3, and 24R,25(OH)2D3; assigned values for critical samples for VDSP studies, including an extensive interlaboratory comparison and reference material commutability study; provided an accuracy basis for the Vitamin D External Quality Assurance Scheme; coordinated the first accuracy-based measurement QA program for the determination of 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3 in human serum/plasma; and developed methods and SRMs for the determination of vitamin D and 25(OH)D in food and supplement matrix SRMs. The details of these activities and their benefit and impact to the NIH-ODS Vitamin D Initiative are described.


Assuntos
25-Hidroxivitamina D 2/sangue , Análise Química do Sangue/normas , Humanos , National Institutes of Health (U.S.) , Controle de Qualidade , Estados Unidos , Vitamina D
5.
Anal Chem ; 89(9): 4907-4913, 2017 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-28375002

RESUMO

The National Institute of Standards and Technology (NIST) has developed Standard Reference Material (SRM) 972a Vitamin D Metabolites in Frozen Human Serum as a replacement for SRM 972, which is no longer available. SRM 972a was developed in collaboration with the National Institutes of Health's Office of Dietary Supplements. In contrast to the previous reference material, three of the four levels of SRM 972a are composed of unmodified human serum. This SRM has certified and reference values for the following 25-hydroxyvitamin D [25(OH)D] species: 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3. The value assignment and certification process included three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). The value assignment methods employed have been modified from those utilized for the previous SRM, and all three approaches now incorporate chromatographic resolution of the stereoisomers, 25(OH)D3 and 3-epi-25(OH)D3.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Cromatografia Líquida/normas , Espectrometria de Massas/normas , 25-Hidroxivitamina D 2/normas , Calcifediol/química , Calcifediol/normas , Humanos , Padrões de Referência , Valores de Referência , Estereoisomerismo , Estados Unidos , United States Government Agencies
6.
Anal Bioanal Chem ; 405(13): 4531-8, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23371533

RESUMO

As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed Standard Reference Material (SRM) 3274 Botanical Oils Containing Omega-3 and Omega-6 Fatty Acids and SRM 3275 Omega-3 and Omega-6 Fatty Acids in Fish Oil. SRM 3274 consists of one ampoule of each of four seed oils (3274-1 Borage (Borago officinalis), 3274-2 Evening Primrose (Oenothera biennis), 3274-3 Flax (Linium usitatissimum), and 3274-4 Perilla (Perilla frutescens)), and SRM 3275 consists of two ampoules of each of three fish oils (3275-1 a concentrate high in docosahexaenoic acid, 3275-2 an anchovy oil high in docosahexaenoic acid and eicosapentaenoic acid, and 3275-3 a concentrate containing 60% long-chain omega-3 fatty acids). Each oil has certified and reference mass fraction values for up to 20 fatty acids. The fatty acid mass fraction values are based on results from analyses using gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS). These SRMs will complement other reference materials currently available with mass fractions for similar analytes and are part of a series of SRMs being developed for dietary supplements.


Assuntos
Suplementos Nutricionais/normas , Ácidos Docosa-Hexaenoicos/normas , Ácido Eicosapentaenoico/normas , Óleos de Peixe/normas , Óleos de Plantas/normas , Cromatografia Gasosa , Suplementos Nutricionais/análise , Ácidos Docosa-Hexaenoicos/isolamento & purificação , Ácido Eicosapentaenoico/isolamento & purificação , Óleos de Peixe/química , Ionização de Chama , Humanos , Óleos de Plantas/química , Padrões de Referência , Valores de Referência
7.
J Agric Food Chem ; 60(27): 6794-8, 2012 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-22686411

RESUMO

Standard Reference Material (SRM) 3278 Tocopherols in Edible Oils has been issued for use as a quality assurance tool in the measurement of tocopherols. Like other natural-matrix SRMs, this material can be used in method validation or in assignment of tocopherol values to in-house quality control materials. Because most edible oils contain one predominant tocopherol isoform, the SRM is a blend of sunflower, soy, canola, and safflower oils to provide roughly comparable chromatographic peak heights of the two main tocopherols, γ and α, with smaller amounts of δ and ß. The four tocopherol isoforms were determined by three independent liquid chromatography methods with absorbance and fluorescence detection. Various chromatographic and detection modes are used for assignment of certified values because biases inherent to one method should not be present in the other, and the existence of bias can therefore be identified.


Assuntos
Cromatografia Líquida/normas , Óleos de Plantas/normas , Tocoferóis/normas , Cromatografia Líquida/métodos , Óleos de Plantas/análise , Controle de Qualidade , Padrões de Referência , Tocoferóis/análise
8.
Anal Chem ; 84(2): 956-62, 2012 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-22141317

RESUMO

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health's Office of Dietary Supplements (NIH-ODS), has developed a Standard Reference Material (SRM) for the determination of 25-hydroxyvitamin D [25(OH)D] in serum. SRM 972 Vitamin D in Human Serum consists of four serum pools with different levels of vitamin D metabolites and has certified and reference values for 25(OH)D(2), 25(OH)D(3), and 3-epi-25(OH)D(3). Value assignment of this SRM was accomplished using a combination of three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). Chromatographic resolution of the 3-epimer of 25(OH)D(3) proved to be essential for accurate determination of the metabolites.


Assuntos
Vitamina D/análogos & derivados , Cromatografia Líquida , Humanos , Espectrometria de Massas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Vitamina D/análise , Vitamina D/sangue , Vitamina D/normas
9.
J AOAC Int ; 94(3): 803-14, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21797008

RESUMO

The National Institute of Standards and Technology (NIST) has established a Dietary Supplement Laboratory Quality Assurance Program (DSQAP) in collaboration with the National Institutes of Health Office of Dietary Supplements. Program participants measure concentrations of active and/or marker compounds as well as nutritional and toxic elements in food and dietary supplements distributed by NIST. Data are compiled at NIST, where they are analyzed for accuracy relative to reference values and concordance among the participants. Performance reports and certificates of completion are provided to participants, which can be used to demonstrate compliance with current Good Manufacturing Practices as promulgated by the U.S. Food and Drug Administration. The DSQAP has conducted five exercises to date, with total participation including more than 75 different laboratories and many more individual analysts.


Assuntos
Suplementos Nutricionais/análise , Suplementos Nutricionais/normas , Laboratórios/normas , Preparações de Plantas/química , Vitaminas/química , Ácidos Graxos/química , Ácidos Graxos/normas , Análise de Alimentos/normas , Preparações de Plantas/normas , Controle de Qualidade , Estados Unidos
10.
Anal Chem ; 83(1): 92-8, 2011 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21117618

RESUMO

Vitamins are essential to human health, and dietary supplements containing vitamins are widely used by individuals hoping to ensure they have adequate intake of these important nutrients. Measurement of vitamins in nutritional formulations is necessary to monitor regulatory compliance and in studies examining the nutrient intake of specific populations. Liquid chromatographic methods, primarily with UV absorbance detection, are well established for both fat- and water-soluble measurements, but they do have limitations for certain analytes and may suffer from a lack of specificity in complex matrices. Liquid chromatography-mass spectrometry (LC-MS) provides both sensitivity and specificity for the determination of vitamins in these matrices, and simultaneous analysis of multiple vitamins in a single analysis is often possible. In this work, LC-MS methods were developed for both fat- and water-soluble vitamins and applied to the measurement of these analytes in two NIST Standard Reference Materials. When possible, stable isotope labeled internal standards were employed for quantification.


Assuntos
Cromatografia Líquida/métodos , Suplementos Nutricionais/análise , Lipídeos/química , Espectrometria de Massas/métodos , Vitaminas/análise , Vitaminas/química , Água/química , Cromatografia Líquida/normas , Técnicas de Diluição do Indicador , Isótopos , Espectrometria de Massas/normas , Padrões de Referência , Solubilidade , Comprimidos
11.
Anal Bioanal Chem ; 398(1): 425-34, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20582402

RESUMO

Nine organic acids (citric acid, galacturonic acid, glycolic acid, isocitric acid, malic acid, oxalic acid, quinic acid, shikimic acid, and tartaric acid) and two anions (phosphate and sulfate) were determined in a suite of Vaccinium berry-containing dietary supplement standard reference materials (SRMs). Following solvent extraction, three independent methods were utilized in the quantification of these compounds. The first method involved reversed-phase liquid chromatography with ultraviolet absorbance detection at 210 nm and isotope dilution mass spectrometry. The second method utilized ion chromatography with conductivity detection. Finally, gas chromatography with isotope dilution mass spectrometry detection was used following derivatization with N-methyl-N-trifluoroacetamide (MSTFA). The combined data from these methods was used for the assignment of organic acid levels in the seven candidate SRMs.


Assuntos
Ácidos/análise , Ácidos/normas , Suplementos Nutricionais/análise , Suplementos Nutricionais/normas , Frutas/química , Vaccinium/química , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa , Cromatografia Gasosa-Espectrometria de Massas , Marcação por Isótopo , Espectrometria de Massas , Padrões de Referência
12.
Anal Bioanal Chem ; 397(5): 1773-7, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20422160

RESUMO

Theanine is the major amino acid present in Camellia sinensis or green tea. A method for determining theanine in its native state using liquid chromatography with positive-mode electrospray ionization mass spectrometric detection was developed. Quantitation of theanine was achieved using theanine-[(2)H(5)] as an internal standard. This approach was utilized on different green tea matrix materials that are commonly used as dietary supplements including powdered plant leaves, a powdered plant leaf extract, and an oral dosage form that contains green tea. The theanine response was linear over several orders of magnitude, and excellent measurement precision was obtained for all three materials using the developed method.


Assuntos
Camellia sinensis/química , Cromatografia Líquida/métodos , Glutamatos/análise , Extratos Vegetais/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Chá/química
13.
Anal Bioanal Chem ; 392(3): 427-38, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18677464

RESUMO

As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.


Assuntos
Frutas/química , Extratos Vegetais/análise , Extratos Vegetais/química , Serenoa/química , Ácidos Graxos/análise , Padrões de Referência , Esteróis/análise , Tocoferóis/química , beta Caroteno/análise
14.
J Agric Food Chem ; 55(24): 9769-75, 2007 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-17966980

RESUMO

The predominant adrenergic protoalkaloid found in the peel and fruit of bitter orange, Citrus aurantium, is synephrine. Synephrine is reputed to have thermogenic properties and is used as a dietary supplement to enhance energy and promote weight loss. However, there exists some concern that the consumption of dietary supplements containing synephrine or similar protoalkaloids may contribute to adverse cardiovascular events. This study developed and validated a positive-ion mode liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the quantitative determination of the major (synephrine) and minor (tyramine, N-methyltyramine, octopamine, and hordenine) adrenergic protoalkaloids in a suite of National Institute of Standards and Technology (NIST) bitter orange Standard Reference Materials (SRMs): SRM 3258 Bitter Orange Fruit, SRM 3259 Bitter Orange Extract, and SRM 3260 Bitter Orange Solid Oral Dosage Form. The limit of quantitation (LOQ) for all protoalkaloids is approximately 1 pg on-column, except for octopamine (20 pg on-column). Additionally, the method has a linear dynamic range of > or =3 orders of magnitude for all of the protoalkaloids. Individual, as well as "total", protoalkaloid levels (milligrams per kilogram) in the NIST SRMs were determined and compared to the levels measured by an independent liquid chromatography/fluorescence detection (LC/FD) method. Satisfactory concordance between the LC/MS/MS and LC/FD protoalkaloid measurements was demonstrated. LC/MS/MS analysis of the protoalkaloids in the SRMs resulted in mean measurement imprecision levels of < or =10% coefficient of variation (% CV).


Assuntos
Alcaloides/análise , Citrus/química , Espectrometria de Massas/métodos , Sinefrina/análise , Espectrometria de Massas em Tandem/métodos , Suplementos Nutricionais/análise , Sensibilidade e Especificidade , Espectrometria de Fluorescência/métodos
15.
Anal Bioanal Chem ; 389(1): 179-96, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17619180

RESUMO

A suite of three ginkgo-containing dietary supplement Standard Reference Materials (SRMs) has been issued by the National Institute of Standards and Technology (NIST) with certified values for flavonoid aglycones, ginkgolides, bilobalide, and selected toxic trace elements. The materials represent a range of matrices (i.e., plant, extract, and finished product) that provide different analytical challenges. The constituents have been determined by at least two independent analytical methods with measurements performed by NIST and at least one collaborating laboratory. The methods utilized different extractions, chromatographic separations, modes of detection, and approaches to quantitation. The SRMs are primarily intended for method validation and for use as control materials to support the analysis of dietary supplements and related botanical materials.


Assuntos
Suplementos Nutricionais/análise , Suplementos Nutricionais/normas , Ginkgo biloba/química , Arsênio/análise , Arsênio/toxicidade , Cromatografia Líquida , Flavonoides/química , Ginkgolídeos/química , Lactonas/química , Metais Pesados/análise , Metais Pesados/toxicidade , Estrutura Molecular , Padrões de Referência , Espectrometria de Massas por Ionização por Electrospray , Terpenos/química
16.
Anal Bioanal Chem ; 389(1): 197-205, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17579842

RESUMO

A liquid chromatographic atmospheric-pressure ionization electrospray mass spectrometry (LC-API-ES-MS) method has been developed for the determination of five bitter orange alkaloids (synephrine, octopamine, n-methyltyramine, tyramine, and hordenine) in bitter orange-containing dietary supplement standard reference materials (SRMs). The materials represent a variety of natural, extracted, and processed sample matrices. Two extraction techniques were evaluated: pressurized-fluid extraction (PFE) and sonication extraction. The influence of different solvents, extraction temperatures, and pH were investigated for a plant material and a processed sample. The LC method uses a new approach for the separation of highly polar alkaloids. A fluorinated, silica-based stationary phase separated the five alkaloids and the internal standard terbutaline in less than 20 min. This method enabled the determination of the dominant alkaloid synephrine and other minor alkaloids in a variety of dietary supplement SRMs.


Assuntos
Alcaloides/análise , Alcaloides/química , Cromatografia Líquida/métodos , Citrus sinensis/química , Suplementos Nutricionais/análise , Suplementos Nutricionais/normas , Espectrometria de Massas por Ionização por Electrospray/métodos , Produtos Biológicos/química , Estrutura Molecular , Extratos Vegetais/química , Pressão , Padrões de Referência , Sonicação
17.
Anal Bioanal Chem ; 389(1): 171-8, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17534610

RESUMO

Well-characterized certified reference materials are needed by laboratories in the food testing, dietary supplement, and nutrition communities to facilitate compliance with labeling laws and improve the accuracy of information provided on product labels, so that consumers can make good choices. As a result of the enactment of the Nutrition Labeling and Education Act of 1990 and the Infant Formula Act of 1980, the National Institute of Standards and Technology (NIST) worked to develop a series of food-matrix standard reference materials (SRMs) characterized for nutrient concentrations. These include SRM 1544 Fatty Acids and Cholesterol in a Frozen Diet Composite, SRM 1546 Meat Homogenate, SRM 1548a Typical Diet, SRM 1566b Oyster Tissue, SRM 1846 Infant Formula, SRM 1946 Lake Superior Fish Tissue, SRM 1947 Lake Michigan Fish Tissue, SRM 2383 Baby Food Composite, SRM 2384 Baking Chocolate, SRM 2385 Slurried Spinach, and SRM 2387 Peanut Butter. With the enactment of the Dietary Supplement Health and Education Act of 1994, NIST has been working to develop suites of dietary supplement SRMs characterized for active and marker compounds and for toxic elements and pesticides, where appropriate. An updated SRM 1588b Organics in Cod Liver Oil, a suite of ephedra-containing materials (SRMs 3240-3245), a carrot extract in oil (SRM 3276), and a suite of ginkgo-containing materials (SRMs 3246-3248) are available. Several other materials are currently in preparation. Dietary supplements are sometimes provided in forms that are food-like; for these, values may also be assigned for nutrients, for example SRM 3244 Ephedra-Containing Protein Powder. Both the food-matrix and dietary supplement reference materials are intended primarily for validation of analytical methods. They may also be used as "primary control materials" in assignment of values to in-house (secondary) control materials to confirm accuracy and to establish measurement traceability to NIST.


Assuntos
Suplementos Nutricionais/análise , Suplementos Nutricionais/normas , Análise de Alimentos/normas , Animais , Humanos , Padrões de Referência , United States Government Agencies
18.
Anal Bioanal Chem ; 389(1): 207-17, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17440713

RESUMO

The National Institute of Standards and Technology (NIST), the Food and Drug Administration (FDA) Center for Drug Evaluation and Research (CDER) and Center for Food Safety and Applied Nutrition (CFSAN), and the National Institutes of Health (NIH), Office of Dietary Supplements (ODS) are collaborating to produce a series of standard reference materials (SRMs) for dietary supplements. Standard reference material (SRM) 3276 Carrot Extract in Oil is one in this series, with values assigned for trans-alpha-carotene, trans- and total beta-carotene, delta- and gamma-tocopherol, and twelve fatty acids. Results for carotenoids and tocopherols were obtained by use of combinations of liquid chromatography (LC), on columns of differing selectivity, with absorbance and mass spectrometric (MS) detection. Fluorescence detection also was used for the tocopherols. Results for fatty acids were obtained by use of gas chromatography (GC) with both flame-ionization and mass-spectrometric detection. This material is intended for use as a primary control material when assigning values to in-house (secondary) control materials and for validation of analytical methods for measurement of these analytes in similar matrices.


Assuntos
Daucus carota/química , Extratos Vegetais/química , Óleos de Plantas/análise , Óleos de Plantas/normas , Carotenoides/química , Cromatografia Gasosa , Cromatografia Líquida , Ésteres/química , Ácidos Graxos/química , Metilação , Óleos de Plantas/química , Padrões de Referência , Tocoferóis/química , United States Government Agencies
19.
J Agric Food Chem ; 54(23): 8710-6, 2006 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-17090111

RESUMO

Two independently developed liquid chromatography (LC) methods for the quantitative determination of biotin in multivitamin/multielement tablets (NIST Standard Reference Material 3280 (SRM 3280)) are described. The methods use distinctly different tablet extraction solvents (methanol vs 1.5% aqueous formic acid) and analyte detection principles (mass spectrometry (MS) versus evaporative light-scattering detection (ELSD)) to ensure quantitative reliability. The use of different extraction and detection procedures allows cross-validation of the methods and enhances confidence in the final quantitative results. Both methods yield highly comparable results for the mean level of biotin (LC/MS = 26.5 mg/kg +/- 0.3 mg/kg (n = 12); LC/ELSD = 24.7 mg/kg +/- 1.7 mg/kg (n = 12)) in SRM 3280, yet the methods differ considerably in their analytical characteristics. The isotope-dilution LC/MS method exhibits excellent linearity from 0.02 ng to 77 ng biotin on-column with a method limit of detection (LOD) and limit of quantification (LOQ) of 0.02 ng (S/N > 3) and 0.06 ng (S/N > 10) biotin on-column, respectively. The LC/ELSD method exhibits good linearity from 155 ng to 9900 ng biotin on-column with a method LOD and LOQ of 155 ng (S/N > 3) and 310 ng (S/N > 10) biotin on-column, respectively. Method performance data indicates that the LC/MS method is analytically superior to the LC/ELSD method; however, either method in combination with SRM 3280 should provide quality assurance, accuracy, and traceability for biotin levels in multivitamin/multielement dietary supplements.


Assuntos
Biotina/análise , Cromatografia Líquida/métodos , Suplementos Nutricionais/análise , Luz , Espectrometria de Massas , Padrões de Referência , Espalhamento de Radiação , Comprimidos/análise
20.
J Chromatogr A ; 1135(2): 203-11, 2006 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-17018234

RESUMO

Two different isotope-dilution liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods for the quantitative determination of folic acid (FA) in multivitamin/multielement tablets are reported. These methods represent distinct improvements in terms of speed and specificity over most existing microbiological and chromatographic methods for the determination of FA in dietary supplements. The first method utilizes an aqueous/organic-based extraction solvent combined with positive-ion mode LC/MS/MS detection of protonated [M + H]+ FA molecules and the second method utilizes a pure aqueous-based extraction solvent combined with negative-ion mode LC/MS/MS detection of deprotonated [M - H]- FA molecules. The LC/MS/MS methods exhibit comparable linear dynamic ranges (> or =3 orders of magnitude), limits of detection (0.02 ng on-column) and limits of quantification (0.06 ng on-column) for FA. Two methods employing different extraction and different MS detection modes were developed to allow method cross-validation. Successful validation of each measurement procedure supports the use of either method for the certification of FA levels in dietary supplements. The accuracy and precision of each measurement procedure were evaluated by applying each method to the quantitative determination of FA in a NIST standard reference material (NIST SRM 3280 multivitamin/multielement tablets). The FA measurement accuracy for both methods was > or =95% (based on the manufacturer's assessment of the FA level in SRM 3280) with corresponding measurement precision values (% RSD) of approximately 1%.


Assuntos
Cromatografia Líquida/métodos , Suplementos Nutricionais/análise , Ácido Fólico/análise , Espectrometria de Massas/métodos , Comprimidos/química , Vitaminas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA