Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Diagn Interv Radiol ; 22(4): 354-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27306661

RESUMO

PURPOSE: Splenic artery embolization is a minimally invasive therapeutic procedure utilized in a number of disorders. Ankaferd blood stopper (ABS) is a novel hemostatic agent with a new mechanism of action independent of clotting factors. We aimed to investigate the safety and efficiency of ABS for splenic artery embolization in a sheep model. METHODS: Seven adult female sheep were included in the study. Selective celiac angiography was performed using a 5F diagnostic catheter and then a 2.7F hydrophilic coating microcatheter was advanced coaxially to the distal part of the main splenic artery. Under fluoroscopic guidance, 6 mL mixture composed of half-and-half ABS and contrast agent was slowly injected. Fluoroscopy was used to observe the deceleration and stagnation of the flow. Control celiac angiograms were obtained immediately after the embolization. After the procedure, the animals were observed for one day and then sacrificed with intravenous sodium thiopental. RESULTS: Technical success rate was 100%. None of the animals died or experienced a major systemic adverse event during the procedure. All of the spleens appeared dark on macroscopic examination due to excessive thrombosis. Microscopically, the majority of the splenic sinusoids (90%-95%) were necrotic. CONCLUSION: In our study, splenic artery embolization by ABS was found to be safe and effective in the short-term. Further studies are needed to better understand the embolizing potential of this novel hemostatic agent.


Assuntos
Embolização Terapêutica/métodos , Extratos Vegetais/administração & dosagem , Angiografia , Animais , Feminino , Humanos , Modelos Animais , Ovinos , Artéria Esplênica
2.
Cardiovasc Intervent Radiol ; 36(2): 498-504, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22610300

RESUMO

PURPOSE: Renal artery embolization (RAE) is a minimally invasive therapeutic technique that is utilized in a number of disorders. Ankaferd is a novel hemostatic agent with a new mechanism of action independent of clotting factors. We used Ankaferd for RAE in a sheep model. METHODS: Seven adult female sheep were included in the study. Selective renal arteriogram using 5-F diagnostic catheter was performed to make sure that each kidney was fed by a single renal artery and the animal had normal renal vasculature. Coaxial 2.7-F microcatheter was advanced to the distal main renal artery. Under fluoroscopic guidance, 2 mL of Ankaferd mixed with 2 mL of nonionic iodinated contrast agent was slowly injected. Fluoroscopy was used to observe the deceleration of flow and stagnation. Control renal angiograms were performed just after embolization. After the procedure, the animals were observed for 1 day and then sacrificed with intravenous sodium thiopental. RESULTS: The technical success was observed in seven of the seven animals.. After embolization procedure, none of the animals died or experienced a major systemic adverse event. On macroscopic examination of the embolized kidneys, thrombus at the level of main renal artery formed after Ankaferd embolization was more compact compared with the thrombi that was not Ankaferd-associated, which was observed elsewhere. Microscopically, majority of the renal tubular cells (80-90 %) were necrotic, and there was epithelial cell damage in a small portion of the cells (10-20 %). CONCLUSIONS: RAE was safe and effective in the short-term with Ankaferd in studied animals. Further studies should be conducted to better delineate the embolizing potential of this novel hemostatic agent.


Assuntos
Embolização Terapêutica/métodos , Extratos Vegetais/farmacologia , Artéria Renal , Angiografia , Animais , Meios de Contraste/farmacologia , Feminino , Fluoroscopia , Carneiro Doméstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA