Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 100(9): e23799, 2021 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-33655906

RESUMO

BACKGROUND: Colonoscopy is an uncomfortable procedure. Distraction is thought to reduce pain by decreasing the amount of attention a person spends on a painful stimulus. We aimed to assess the usefulness of smartphones on discomfort associated with the colonoscopy. METHODS: We designated 360 enrolled patients according to prospective randomized controlled study into two groups, including smartphone (SP) group (Relaxation by smartphones) and Control group (No relaxation). Measured outcomes included the discomfort, satisfaction, polyp detection rate and the willingness to repeat colonoscopy were analyzed between groups. RESULTS: The pain and distension scores of SP group patients were significantly lower than those of the Control group (2.18 ±â€Š2.80 vs 3.55 ±â€Š3.07, P < .001; 4.15 ±â€Š2.35 vs 4.79 ±â€Š2.36, P = .011, respectively). Importantly, patient-reported satisfaction scores of the SP group were significantly higher than those of the Control group (96.45 ±â€Š7.17 vs 91.12 ±â€Š10.49, respectively; P < .001). Moreover, although there were no statistical differences, patients using smartphones were more likely to have shorter reach cecum times (09m:11 s vs 07m:37 s, P = .116) and more polyp detection rate (13.3% vs 9.4%, P = .246). In addition, more patients using smartphones were willing to repeat colonoscopy but no statistical difference (85.0% vs 81.7%, P = .396). CONCLUSION: Patient using smartphone is a special manner to increase satisfaction during colonoscopy with a less discomfort and is more likely to be polyp detection rate.


Assuntos
Colonoscopia/psicologia , Dor Processual/terapia , Satisfação do Paciente , Terapia de Relaxamento/instrumentação , Smartphone , Adolescente , Adulto , Colonoscopia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Dor Processual/psicologia , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
2.
J Chromatogr Sci ; 53(2): 285-94, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24920653

RESUMO

A simple method based on liquid chromatography-full-scan high-resolution accurate mass spectrometry (LC-HRMS) using a quadrupole time-of-flight (TOF) mass spectrometry was developed and optimized for corticosterone quantification in mouse plasma. Mouse plasma (100 µL) was extracted with methyl tert-butyl ether using prednisone as internal standard. Separation was performed on a short C18 column using a methanol-water gradient. Full-scan data were acquired in the TOF only mode, and extracted ion chromatograms were generated post-acquisition with the extract masses of the analytes. Enhanced sensitivity and reproducibility were acquired with optimized mass parameters. The calibration range was 8.24-412 ng/mL, and the limit of quantitation was 5.088 g/mL. Accuracy was between -5.9 and 8.6%. The precision of between-run (interday) and within-run (intraday) was within 5.6 and 6.9%, respectively. The LC-HRMS method was applied for plasma samples analysis from the stressed mice with and without ginseng treatment for the stress state estimation.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Corticosterona/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Modelos Lineares , Masculino , Camundongos , Panax , Reprodutibilidade dos Testes , Saponinas , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA