RESUMO
Water chestnut (Trapa bispinosa Roxburg) has short shelf life even after drying due to insect infestations resulting in huge economic losses to farmers. Study was performed including coating with Aloe-vera gel, air drying, LDPE packaging and gamma irradiation (≤ 1 kGy) were evaluated for their efficacy in controlling storage losses. The study was performed with complete randomized design up to 6-month storage period. Physico-chemical properties analysis indicated, weight loss (0.11-0.88%), damage (upto 6.5%) and lesser grain borer infestation (up to 16 no. per packet) during storage at different intervals. Moisture content ranged (9.25-10.10%), protein (8.82-8.89%), fat (0.90-1.00%), carbohydrate (76.83-76.89%), total ash (3.11-4.18%), total sugar (5.83-5.89%), reducing sugar (1.84-1.88%), non-reducing sugar (3.98-4.02%), amylose (66.54-66.64%), in-vitro starch digestibility (3.14-3.18%), phenolics (0.14-0.18%), acidity (0.11-0.12%) and ascorbic acid (41.66-50.00 mg/100 g). These treatments were not found to affect the quality attributes significantly however; it helps in controlling insect infestations at ambient condition. The sensory score of the product, 'Sev' was ranked as like slightly to moderately range. It could be concluded that water chestnut with combinations of 50% aloe-vera gel +0.75 kGy gamma radiation treatment could be stored up to 6 months with retention of quality attributes.
RESUMO
We have developed a simple method for locating functional regions of interest on successive SPECT scans obtained at different times and for locating neuroanatomical regions defined with MR on functional images obtained with SPECT. Plastic molds are made for each external auditory meatus and the glabella. A pocket is then made in each mold in which either a 57Co disk (for SPECT) or an identical disk containing CuSO4 solution (for MRI) can be placed. Transaxial tomographic slices are reconstructed with the same slice thickness in the two modalities. The SPECT software rotates both SPECT and MRI reconstructed images so that the three 57Co markers lie in one SPECT reference plane and the three CuSO4 markers lie in one MRI reference plane. Corresponding SPECT and MR images may then be displayed simultaneously to locate chosen regions of interest. The technique was validated by taping test markers to the forehead of 12 subjects; the difference between the positions of the centers of the test markers on SPECT and MR scans was within 1 SPECT acquisition pixel size.