1.
Clin Biochem ; 33(3): 191-6, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10913517

RESUMO

OBJECTIVES: To evaluate a turbidimetric immunoassay for the measurement of ferritin, and to assay this method in a group of patients undergoing an autologous blood transfusion program. DESIGN AND METHODS: We used an ILab 900 analyzer. This instrument automates a particle-enhanced immunoturbidimetric assay with an analysis time of 9 min. This technique was compared with a microparticle immunoassay. The turbidimetric assay was used to measure ferritin in a group of 30 patients undergoing an autologous blood transfusion program. RESULTS: The assay was linear in the range 3-1400 microg/L (r = 0.9999). The intra- and inter-assay imprecision (CV) at 20, 97 and 469 microg/L were <3.0 and <5.0%, respectively. Recovery was 88. 7 to 97.4%. The detection limit was 3 microg/L. Hemoglobin (

Assuntos
Estudos de Avaliação como Assunto , Ferritinas/análise , Imunoensaio/métodos , Nefelometria e Turbidimetria/métodos , Adulto , Idoso , Transfusão de Sangue Autóloga , Feminino , Ferritinas/sangue , Ferritinas/imunologia , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência
2.
Transfusion ; 36(9): 822-6, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8823459

RESUMO

BACKGROUND: Clinical and pharmacokinetic data suggest that very low doses of subcutaneous recombinant human erythropoietin (rHuEPO) may be effective in a preoperative autologous blood deposit program. STUDY DESIGN AND METHODS: Fifty-two patients, scheduled for orthopedic surgery, were enrolled in a double-blind and placebo-controlled study. Patients were randomly assigned to the placebo group or to receive 30, 60, or 100 IU per kg of rHuEPO subcutaneously twice a week for 2 weeks before surgery. The dose of rHuEPO that was effective in facilitating the collection of 4 units of blood in the 2 weeks before surgery and that prevented a sharp decrease in hematocrit was determined. RESULTS: Only in patients receiving 100 IU per kg of rHuEPO did the outcome measurements differ significantly from those in the placebo group. With a higher (p < 0.01) cumulative increase in red cell volume during the study period (297 +/- 127 vs. 121 +/- 44 mL), 64 percent of those receiving 100 IU per kg of rHuEPO were able to donate 4 units of blood for autologous use, as compared with 23 percent of the placebo group (p < 0.05). Allogeneic transfusion was avoided, and the preoperative hematocrit and reticulocyte count were significantly higher in the patients receiving 100 IU per kg of rHuEPO (p < 0.05 and p < 0.01, respectively). CONCLUSION: Subcutaneously administered rHuEPO at a dose of 100 IU per kg twice a week for 2 weeks is effective in facilitating the collection of blood for autologous use and may improve the cost-benefit ratio of blood conservation interventions. Doses < or = 60 IU per kg are ineffective in facilitating such collections in this surgical setting.


Assuntos
Transfusão de Sangue Autóloga/métodos , Eritropoetina/administração & dosagem , Idoso , Eritropoese/efeitos dos fármacos , Feminino , Hematócrito , Quadril/cirurgia , Prótese de Quadril , Humanos , Injeções Subcutâneas , Joelho/cirurgia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Proteínas Recombinantes , Contagem de Reticulócitos
3.
Clin Chem ; 40(4): 625-9, 1994 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8149621

RESUMO

A considerable demand for convenient, rapid, inexpensive assays of ferritin in serum has been generated in recent years in hospital laboratories and blood banks. We describe a simple and rapid particle-enhanced turbidimetric immunoassay suitable for routine application in a Monarch 2000 centrifugal analyzer with commercially available reagents. This fully automated assay (y) requires no pretreatment of sample, and correlation with a two-step sandwich ELISA (x) is excellent (y = 1.018x + 0.397, Sy/x = 0.027). The analytical range extends from 5 to 900 micrograms/L. Intraassay imprecision (CV) ranged from 1.1% to 5% for various specimen concentrations. Interassay imprecision ranged from 2.2% for above-normal concentrations (755 micrograms/L) to 9.5% for low concentrations (39 micrograms/L). No specimen-related carryover was detected. The method has been useful in our predeposit autologous blood transfusion program for rapid assessment of iron status in patients undergoing repeated phlebotomies.


Assuntos
Autoanálise , Ferritinas/sangue , Imunoensaio , Testes de Fixação do Látex , Adulto , Transfusão de Sangue Autóloga , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunoensaio/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Valores de Referência , Sensibilidade e Especificidade