1.
Dent Mater ; 8(3): 167-72, 1992 May.
Artigo em Inglês | MEDLINE | ID: mdl-1521704

RESUMO

The frictional coefficients were measured for four wire alloys against the flats of polycrystalline alumina cylinders using a low load, low velocity, single pass device. Ion-implantations of titanium into polycrystalline alumina flats and nitrogen into beta-titanium wires reduced the static and kinetic coefficients from 0.50 and 0.44 before implantation to 0.20 and 0.25 after implantation, respectively. These results are similar in magnitude to frictional coefficients for unimplanted, control couples of stainless steel, cobalt-chromium, and nickel titanium wires against polycrystalline alumina flats. For orthodontic applications, we conclude that more efficient and reproducible appliances can be engineered for tooth movement if ion-implantation is used to reduce the abrasion of beta-titanium by polycrystalline alumina.


Assuntos
Óxido de Alumínio , Ligas Dentárias , Desenho de Aparelho Ortodôntico , Fios Ortodônticos , Ligas de Cromo , Troca Iônica , Análise de Regressão , Aço Inoxidável , Titânio