Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Medicinas Complementares
Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Isotopes Environ Health Stud ; 54(5): 451-462, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30081672

RESUMO

The monitoring and evaluation of radioactive content in samples of PM10 aerosols have been investigated. The specific radioactivity concentrations (SRC) of 234U, 235U, 238U and 232Th were determined using inductively coupled plasma-sector field mass spectrometry in 13 samples collected in Mexico City and 8 samples collected in Cuernavaca in the centre of Mexico. The SRC of the radioisotopes analysed in PM10 were larger than those reported in PM2.5. The enrichment factor was greater than 5, indicating anthropogenic influences in both sites. The activity ratios of these isotopes in the samples were determined. The 235U/238U ratio showed variations with respect to the natural value, while the 234U/238U and 232Th/238U ratios did not show any secular equilibrium in all sites, corroborating that the increase of uranium is not influenced by natural sources. The annual dose results obtained have no impact on health.


Assuntos
Aerossóis/análise , Poluentes Radioativos do Ar/análise , Tório/análise , Urânio/análise , Cidades , Monitoramento Ambiental/métodos , Espectrometria de Massas/métodos , México , Material Particulado/análise , Cinza Radioativa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA