Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Thromb Haemost ; 122(1): 20-47, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34773920

RESUMO

The consensus of the Asia Pacific Heart Rhythm Society (APHRS) on stroke prevention in atrial fibrillation (AF) has been published in 2017 which provided useful clinical guidance for cardiologists, neurologists, geriatricians, and general practitioners in the Asia-Pacific region. In these years, many important new data regarding stroke prevention in AF were reported. The practice guidelines subcommittee members comprehensively reviewed updated information on stroke prevention in AF, and summarized them in this 2021 focused update of the 2017 consensus guidelines of the APHRS on stroke prevention in AF. We highlighted and focused on several issues, including the importance of the AF Better Care pathway, the advantages of non-vitamin K antagonist oral anticoagulants (NOACs) for Asians, the considerations of use of NOACs for Asian AF patients with single one stroke risk factor beyond gender, the role of lifestyle factors on stroke risk, the use of oral anticoagulants during the "coronavirus disease 2019" pandemic, etc. We fully realize that there are gaps, unaddressed questions, and many areas of uncertainty and debate in the current knowledge of AF, and the physician's decision remains the most important factor in the management of AF.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Acidente Vascular Cerebral/prevenção & controle , Síndrome Coronariana Aguda/complicações , Administração Oral , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Ásia/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , COVID-19/complicações , Ablação por Cateter , Feminino , Fatores de Risco de Doenças Cardíacas , Hemorragia/etiologia , Saúde Holística , Humanos , Masculino , Pandemias , Intervenção Coronária Percutânea/efeitos adversos , Medição de Risco , SARS-CoV-2 , Sociedades Médicas , Acidente Vascular Cerebral/epidemiologia
2.
Pacing Clin Electrophysiol ; 39(2): 115-21, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26496657

RESUMO

BACKGROUND: Postpacing interval (PPI) after right ventricular (RV) pacing entrainment minus tachycardia cycle length (TCL) with a correction for atrioventricular (AV) node delay (corrected PPI-TCL) was useful to differentiate atrioventricular node reentrant tachycardia (AVNRT) from orthodromic reciprocating tachycardia (ORT). However, the value of corrected PPI-TCL in determining the site of the accessory pathway (AP) in ORT has not been investigated. The purpose of this study was to assess whether the corrected PPI-TCL is useful in differentiating ORT using a left-sided AP from a right-sided AP. METHODS: We studied 52 patients with ORT using a left-sided AP and 13 patients with a right-sided AP. The PPI was measured upon cessation of the RV pacing at a cycle length 10-40 ms shorter than the TCL. The corrected PPI-TCL was calculated from the subtraction of the increment in AV nodal conduction time of the first PPI from the PPI-TCL. RESULTS: The mean corrected PPI-TCL was 83 ± 20 ms in patients with ORT using a left-sided AP and 27 ± 19 ms in patients with a right-sided AP (P ≤ 0.001). All patients with ORT using a left-sided AP except three patients with left septal AP and none of the patients with ORT using a right-sided AP had a corrected PPI-TCL > 55 ms. CONCLUSIONS: The corrected PPI-TCL after the RV pacing entrainment is useful to guide differentiating ORT using a left-sided AP from a right-sided AP.


Assuntos
Feixe Acessório Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Reciprocante/fisiopatologia , Feixe Acessório Atrioventricular/cirurgia , Adulto , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Reciprocante/cirurgia
3.
J Med Assoc Thai ; 89 Suppl 5: S147-55, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17718256

RESUMO

BACKGROUND AND OBJECTIVE: Observation shows diabetic patients to be more prone to oxidative stress because of hyperglycemia. The elevation of free radical production by this hyperglycemic production may exacerbate cardiovascular complication in diabetes. This study aims to investigate the oxidative stress related parameters in type 2 DM. Since the effects of glycemic control and cardiovascular complications in DM on these parameters has been not fully determined, the comparison between plasma MDA (malondialdehyde) and antioxidant nutrients with their age-matched normal healthy group may be used to determine the susceptibility of oxidative stress in this type of DM. MATERIAL AND METHOD: MDA and antioxidant nutrients (vitamin A, C, E and beta-carotene) were analyzed in plasma of 19 subjects with poorly controlled type 2 DM (fasting plasma glucose [FPG] > 180 mg/dl), 26 subjects with fairly controlled type 2 DM (FPG < or = 180 mg/dl), and 20 subjects with type 2 DM complicated coronary heart disease (CHD) who were matched for age and gender. Twenty healthy subjects with normal plasma glucose level (FPG < 110 mg/dl) and matched for age and gender served as a control group. In all groups of DM these oxidative stress parameters were compared to a normal group. RESULTS: The plasma MDA levels were significantly higher in all types of DM compared to age-matched normal control. Plasma antioxidant vitamin C and E significantly lower only in poorly controlled and CHD complicated type 2 DM, respectively. The mean of plasma vitamin E level was lowest in type 2 DM complicated with CHD. No significant differences in both plasma vitamin A and beta-carotene were noted between any types of DM and age-matched normal healthy group. The positive correlation between MDA and FPG was demonstrated in most group of patients with their normal subjects except in fairly controlled type 2 DM and negative correlation between vitamin E and FPG was also demonstrated in type 2 DM with CHD. CONCLUSION: These findings suggested that diabetic patients were susceptible to oxidative stress and higher plasma glucose level had an association with free radical-mediated lipid peroxidation. The lowest level of vitamin E in type 2 DM complicated with CHD indicated that oxidative stress played an important role in cardiovascular complication and vitamin E supplementation may be necessary for treatment and prevention in this group of diabetics.


Assuntos
Antioxidantes/análise , Diabetes Mellitus Tipo 2/sangue , Peroxidação de Lipídeos/fisiologia , Estado Nutricional , Estresse Oxidativo , Adulto , Idoso , Arteriosclerose/etiologia , Ácido Ascórbico/sangue , Glicemia , Estudos de Casos e Controles , Complicações do Diabetes , Diabetes Mellitus Tipo 2/fisiopatologia , Feminino , Humanos , Hiperglicemia/complicações , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Vitamina E/sangue
4.
Am J Cardiol ; 89(11): 1269-74, 2002 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-12031726

RESUMO

Although ventricular premature complexes (VPCs) in patients without structural heart disease are benign, many patients experience disabling symptoms. Many patients need long-term medication, which is often ineffective and may have adverse effects. Radiofrequency catheter ablation (RFCA) may be an alternative treatment. RFCA was performed in 33 patients with severely symptomatic VPCs that were refractory to medication. Mean VPCs were 23,987 +/- 2,077 beats/24 hours. Twenty-four-hour ambulatory electrocardiographic monitoring, quality of life, and symptoms were assessed at a screening visit and 1 and 12 months after RFCA. RFCA was successfully performed in 32 patients (97%). This resulted in a significant improvement in symptoms, severity of ventricular arrhythmia, and quality of life at 1 and 12 months after the procedure. There were no major complications related to the procedure. Eight patients (24%) had residual arrhythmia. Five of them underwent repeated ablation with successful results. Thus, catheter ablation is a safe and effective treatment for symptomatic ventricular arrhythmia from the right ventricular outflow tract. It also improves the quality of life. Catheter ablation is a viable alternative to drugs in the presence of disabling symptoms.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros/cirurgia , Adulto , Bloqueio de Ramo/cirurgia , Eletrocardiografia , Teste de Esforço , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Resultado do Tratamento , Complexos Ventriculares Prematuros/classificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA